Bryant 548J manual Cont. Electric Heat Electrical Data Tons, Cool

Page 16

548J

Table 7 - (cont.) ELECTRIC HEAT - ELECTRICAL DATA

 

 

7.5 TONS

 

 

 

 

 

 

 

 

 

 

 

 

HZ

 

 

 

 

 

SINGLE POINT KIT PART NUMBER

 

 

---

 

 

 

 

 

 

CRSINGLEXXXXXX

 

UNIT

V---PH

IFM

ELECTRIC HEATER

NOM

APP

 

 

 

 

 

 

 

 

PART NUMBER

PWR

PWR

 

 

 

 

 

TYPE

WITHOUT C.O. or UNPWRD C.O.

WITH PWRD C.O.

CRHEATERXXXXXX

(kW)

(kW)

 

NOM.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WITHOUT P.E.

 

WITH P.E.

WITHOUT P.E.

WITH P.E.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

117A00

10.4

7.8/9.6

049A00

 

049A00

049A00

049A00

 

 

 

110A00

16.0

12.0/14.7

049A00

 

049A00

049A00

049A00

 

 

STD

111A00

24.8

18.6/22.8

051A00

 

051A00

051A00

051A00

 

 

 

112A00

32.0

24.0/29.4

051A00

 

051A00

051A00

051A00

 

 

 

112A00,117A00

42.4

31.8/38.9

053A00

 

053A00

053A00

053A00

 

60

 

 

 

 

 

 

 

 

 

 

 

117A00

10.4

7.8/9.6

049A00

 

049A00

049A00

049A00

 

3---

 

110A00

16.0

12.0/14.7

049A00

 

049A00

049A00

049A00

 

---

MED

111A00

24.8

18.6/22.8

051A00

 

051A00

051A00

051A00

 

208/230

 

 

 

112A00

32.0

24.0/29.4

051A00

 

051A00

051A00

051A00

 

 

 

 

 

 

 

112A00,117A00

42.4

31.8/38.9

053A00

 

053A00

053A00

053A00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

117A00

10.4

7.8/9.6

049A00

 

049A00

049A00

049A00

 

 

 

110A00

16.0

12.0/14.7

049A00

 

049A00

049A00

049A00

 

 

HIGH

111A00

24.8

18.6/22.8

051A00

 

051A00

051A00

051A00

COOL)

 

 

112A00

32.0

24.0/29.4

051A00

 

051A00

051A00

051A00

 

 

112A00,117A00

42.4

31.8/38.9

053A00

 

053A00

053A00

053A00

 

 

 

 

 

 

 

 

 

 

 

 

116A00

13.9

12.8

047A00

 

047A00

047A00

047A00

STAGE---

 

 

115A00

33.0

30.3

050A00

 

050A00

050A00

050A00

 

 

 

113A00

16.5

15.2

047A00

 

047A00

047A00

047A00

 

 

STD

114A00

27.8

25.5

047A00

 

050A00

050A00

050A00

(2

 

 

114A00,116A00

41.7

38.3

052A00

 

052A00

052A00

052A00

548J*08

---603

 

 

 

 

 

 

 

 

 

 

 

 

 

 

116A00

13.9

12.8

047A00

 

047A00

047A00

047A00

 

 

 

113A00

16.5

15.2

047A00

 

047A00

047A00

047A00

 

---

MED

114A00

27.8

25.5

050A00

 

050A00

050A00

050A00

 

460

 

115A00

33.0

30.3

050A00

 

050A00

050A00

050A00

 

 

114A00,116A00

41.7

38.3

052A00

 

052A00

052A00

052A00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

116A00

13.9

12.8

047A00

 

047A00

047A00

047A00

 

 

 

113A00

16.5

15.2

047A00

 

047A00

047A00

047A00

 

 

HIGH

114A00

27.8

25.5

050A00

 

050A00

050A00

050A00

 

 

 

115A00

33.0

30.3

050A00

 

050A00

050A00

050A00

 

 

 

114A00,116A00

41.7

38.3

052A00

 

052A00

052A00

052A00

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

118A00

17.0

17.0

047A00

 

047A00

047A00

047A00

 

---60

119A00

34.0

34.0

050A00

 

050A00

050A00

050A00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

118A00

17.0

17.0

047A00

 

047A00

047A00

047A00

 

---3

MED

 

 

119A00

34.0

34.0

050A00

 

050A00

050A00

050A00

 

575

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH

118A00

17.0

17.0

047A00

 

047A00

047A00

047A00

 

 

119A00

34.0

34.0

050A00

 

050A00

050A00

050A00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

---No Single Point Kit required

LEGEND

APP PWR

--- 208 / 230V / 460V / 575V

C.O.

--- Convenient outlet

FLA

--- Full load amps

IFM

--- Indoor fan motor

NOM PWR

--- 240V / 480V / 600V

P.E.

--- Power exhaust

PWRD

--- Powered convenient outlet

UNPWRD

--- Unpowered convenient outlet

16

Image 16
Contents Product Data Table of Contents Features and Benefits Model Number Nomenclature Factory Options AND/OR Accessories FACTORY-INSTALLED Options and FIELD-INSTALLED AccessoriesOption Accessory FieldConvenience Outlet powered or un-powered Power Exhaust Pressure ReliefFilter or Fan Status Switches Economizer dry-bulb or enthalpyMotormaster Head Pressure Controller Alternate Motors and DrivesThru-the-Base Connections Electric HeatersARI Cooling Rating Tables Minimum Maximum Airflows Electric Heat Sound Performance TablePhysical Data Tons548J*08 548J*09 8.5 TonsMotor Frame Size Fan Qty / Type Electric Heat Electrical Data Single Point KIT Part Number Crsinglexxxxxx UnitElectric Heater NOM APP Part Number PWR Type With Pwrd C.O208/230 Cont. Electric Heat Electrical DataElectric Drive X13 5 speed/torque motor 105A00 16.0 12.0/14.7 038A00 Crheaterxxxxxx Without P.E With P.ECont. Electric Heat Electrical Data Tons Cool460 115A00 33.0 30.3 050A00 575Weights & Dimensions Dimensions 548JDimension Condition Unit disconnect is mounted on panel356 548J*04-07A 610C08679 C08680 356 Application Data Selection Procedure with 548J*07 Example Ambient Temperature Cooling Capacities548J*04 105 115 EA dB 9001200 548J*05 105 115 EA dB1400 548J*06 105 115 EA dB 15002250 2500548J*07 105 115 EA dB 18002100 2400548J*08 105 115 EA dB 26253375 3750548J*09 105 115 EA dB 25502975 3400Temperature AIR Entering Outdoor Coil F db at 70% rh Heating Capacities548J*04 ReturnHeating Capacity Heating Capacity Tons 548J*08Static Pressure Adders Factory Options and/or Accessories General fan performance notesFAN Performance 548J*04 Electric DRIVE, X13 MOTOR, 3 TON Horizontal Supply548J*04 Electric DRIVE, X13 MOTOR, 3 TON Vertical Supply Speed Torque CFM ESP BHP548J*05 Electric DRIVE, X13 MOTOR, 4 TON Vertical Supply 548J*05 Electric DRIVE, X13 MOTOR, 4 TON Horizontal Supply1200 1300 1400 1500 1600 1700 1800 1900 2000 548J*06 Electric DRIVE, X13 MOTOR, 5 TON Vertical Supply 548J*06 Electric DRIVE, X13 MOTOR, 5 TON Horizontal Supply1500 1625 1750 1875 2000 2125 2250 2375 2500 TON Horizontal Supply Available External Static Pressure IN. WG CFM RPM BHP 548J*05CFM RPM BHP 548J*06 1800 927 548J*071800 907 548J*08 2250 5092250 788 847 2250 528548J*09 2550 468 5462550 806 863 2550 495 570Pulley Adjustment Unit MOTOR/DRIVE Combo Motor Pulley Turns OpenECONOMIZER, Barometric Relief and PE Performance 2000 1000Electrical Information 548J*04 Stage Cooling548J*05 Stage Cooling 548J*06 Stage Cooling548J*07 Stage Cooling 548J*08 Stage Cooling Tons548J*09 Stage Cooling Tons Range RLA LRAMCA/MOCP Determination Without C.O. or Unpwrd C.O ELEC. HTRUnit IFM Without P.E With P.E Type FLA DISC. SizeCont. MCA/MOCP Determination Without C.O. or Unpwrd C.O ELEC. HTR UnitType FLA MCA70/74 76/8279/84 46/48Unit IFM Type NOM STD MED HighSee FLA DISC. Size MCA Mocp LRA41.5 197 65/6878/84 43.8 23445.7 205 69/7282/88 48.0 242MCA/MOCP Determination with Pwrd C.O ELEC. HTR With Pwrd C.O Unit IFM Without P.E With P.ECont. MCA/MOCP Determination with Pwrd C.O 111113 10846.5 33.320.2 29.2Electric Heater With Pwrd C.O Without P.E With P.E Electric Heater With Pwrd C.O Unit IFM Without P.E With P.E 50.5 210 74/7888/93 52.8 247Typical Wiring Diagrams Stage Cooling Typical Power DiagramC09065 Multi-Protocol Option Diagram Stage Typical Wiring Diagram C09064 Sequence of Operation Automatic changeover Continuous air circulationCycle-LOCprotection Emergency heatGuide Specifications 548J*04-09 Hvac Guide Specifications23 09 33 Electric and Electronic Control System for Hvac 23 09 93 Sequence of Operations for Hvac Controls23 40 13 Panel Air Filters 23 81 19 Self-Contained Air Conditioners548J 548J 548J 548J 548J Catalog No. PDS548J---01

548J specifications

The Bryant 548J is a high-efficiency gas furnace that combines advanced features and technologies to provide exceptional heating performance. Designed for residential applications, the furnace is notable for its ability to deliver consistent warmth while ensuring energy efficiency and reliability.

One of the main features of the Bryant 548J is its ultra-high efficiency rating, which allows homeowners to save significantly on energy costs. With an Annual Fuel Utilization Efficiency (AFUE) rating of up to 96.5%, this furnace is designed to convert a large portion of fuel into usable heat. This is a remarkable characteristic that not only reduces utility bills but also contributes to a lower environmental footprint.

The 548J is equipped with a modulating gas valve and a variable-speed blower motor. The modulating gas valve enables the furnace to adjust its heating output based on real-time temperature demands, ensuring a more precise heating experience. This results in reduced temperature fluctuations within the home, providing a comfortable living environment. The variable-speed blower motor works in tandem with the modulating valve, facilitating improved air circulation and efficient temperature control.

Additionally, the Bryant 548J features a durable and compact design, making it suitable for various installation spaces. Its quality construction ensures longevity, while the optional stainless steel heat exchanger enhances its reliability. The furnace also includes a quiet operation mode, which minimizes noise levels, ensuring that the unit works quietly in the background without disturbing the household's peace.

Integration with smart home technology is another advantage of the Bryant 548J. Homeowners have the option to connect the furnace to a Wi-Fi-enabled thermostat, allowing for remote temperature control and monitoring. This feature offers enhanced convenience and the ability to optimize energy use according to a homeowner’s schedule.

For peace of mind, the Bryant 548J comes with a range of warranties, protecting the consumer's investment. Bryant’s commitment to quality is reflected in their extensive primary heating testing procedures, which ensure that each unit meets strict performance criteria before it reaches the customer.

In summary, the Bryant 548J is an efficient and reliable gas furnace that embodies advanced heating technology. With features such as high AFUE ratings, modulating gas valves, variable-speed blowers, and smart home compatibility, it stands out as a formidable option for modern residential heating solutions.