Bryant warranty 213ANA060---A Outdoor Section With FY4ANF060 Indoor Section, 1750, 2000, 2250

Page 24

213A

DETAILED COOLING CAPACITIES CONTINUED

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER ENTERING AIR TEMPERATURES deg F

 

 

 

 

 

 

AIR

 

 

 

75

 

 

 

 

85

 

 

 

 

 

 

95

 

 

105

 

 

115

 

 

125

 

 

 

 

 

 

Capacity

 

Total

 

Capacity

 

Total

 

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

CFM

EWB

 

 

MBtuh†

System

 

MBtuh†

 

System

 

 

MBtuh†

System

MBtuh†

System

MBtuh†

System

MBtuh†

System

 

 

 

Total

Sens‡

 

KW**

 

Total

 

Sens‡

 

KW**

 

 

Total

Sens‡

KW**

Total

Sens‡

KW**

Total

Sens‡

KW**

Total

Sens‡

KW**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

213ANA060---A Outdoor Section With FY4ANF060 Indoor Section

 

 

 

 

 

 

 

 

72

 

 

71.08

 

36.09

 

4.41

 

67.69

 

34.77

 

4.86

 

64.09

33.39

5.36

60.33

31.96

5.90

56.30

30.45

6.50

51.84

28.81

7.14

 

 

67

 

 

65.19

 

45.05

 

4.36

 

62.05

 

43.69

 

4.81

 

58.73

42.27

5.30

55.30

40.82

5.85

51.61

39.29

6.44

47.57

37.62

7.09

1750

 

63

 

 

60.79

 

43.67

 

4.31

 

57.85

 

42.31

 

4.76

 

54.78

40.90

5.26

51.57

39.45

5.81

48.15

37.91

6.40

44.41

36.26

7.05

 

 

62

 

 

59.61

 

53.90

 

4.30

 

56.75

 

52.49

 

4.75

 

53.77

51.00

5.25

50.69

49.41

5.80

47.50

47.50

6.40

45.90

45.90

6.36

 

 

57

 

 

57.48

 

57.48

 

4.28

 

55.20

 

55.20

 

4.74

 

52.79

52.79

5.24

50.24

50.24

5.79

47.49

47.49

6.40

44.42

44.42

7.06

 

 

72

 

 

72.12

 

37.62

 

4.54

 

68.55

 

36.26

 

4.99

 

64.87

34.89

5.48

60.98

33.44

6.03

56.80

31.91

6.62

52.19

30.25

7.26

 

 

67

 

 

66.24

 

47.72

 

4.48

 

62.96

 

46.34

 

4.93

 

59.50

44.89

5.43

55.93

43.42

5.97

52.11

41.85

6.57

47.93

40.14

7.21

2000

 

63

 

 

61.83

 

46.19

 

4.44

 

58.77

 

44.80

 

4.89

 

55.56

43.36

5.38

52.22

41.88

5.93

48.67

40.31

6.53

44.80

38.60

7.18

 

 

62

 

 

60.73

 

57.58

 

4.43

 

57.79

 

56.05

 

4.88

 

54.77

54.33

5.38

51.88

51.88

5.93

48.94

48.94

6.53

47.37

47.37

6.51

 

 

57

 

 

59.63

 

59.63

 

4.42

 

57.18

 

57.18

 

4.87

 

54.60

54.60

5.38

51.89

51.89

5.93

48.94

48.94

6.53

45.66

45.66

7.19

 

 

72

 

 

72.83

 

39.05

 

4.66

 

69.16

 

37.69

 

5.11

 

65.40

36.31

5.61

61.39

34.85

6.15

57.10

33.30

6.74

52.35

31.61

7.37

 

 

67

 

 

66.96

 

50.26

 

4.61

 

63.58

 

48.86

 

5.06

 

60.01

47.39

5.55

56.35

45.89

6.09

52.43

44.28

6.69

48.14

42.52

7.33

2250

 

63

 

 

62.58

 

48.57

 

4.56

 

59.40

 

47.16

 

5.01

 

56.09

45.69

5.51

52.66

44.18

6.05

49.01

42.56

6.65

45.05

40.80

7.30

 

 

62

 

 

61.68

 

60.83

 

4.56

 

58.79

 

58.79

 

5.01

 

56.05

56.05

5.51

53.19

53.19

6.06

50.08

50.08

6.66

46.62

46.62

7.31

 

 

57

 

 

61.37

 

61.37

 

4.55

 

58.79

 

58.79

 

5.01

 

 

56.06

56.06

5.51

53.19

53.19

6.06

50.08

50.08

6.66

46.62

46.62

7.31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Indoor Model

 

 

Capacity

 

Power

 

 

Furnace Model

 

 

 

 

 

 

 

 

 

 

 

 

*FY4ANB060

 

 

1.00

1.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FV4BNB006

 

 

1.01

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FX4CN(B,F)060

 

1.01

0.91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP**6021A**

 

0.99

0.99

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP**6024A**

 

1.01

1.01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNPH*6024A**

 

1.00

1.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNPV*6024A**

 

1.00

1.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSPH*6012A**

 

1.01

1.01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP**6021A**

 

0.97

0.94

 

 

 

315(A,J)AV060110

 

 

 

 

 

 

 

 

 

 

 

CNPH*6024A**

 

0.98

0.95

 

 

 

315(A,J)AV060110

 

 

 

 

 

 

 

 

 

 

 

CSPH*6012A**

 

0.99

0.96

 

 

 

315(A,J)AV060110

 

 

 

 

 

 

 

 

 

 

 

CAP**6024A**

 

0.99

0.93

 

 

 

315(A,J)AV066135

 

 

 

 

 

 

 

 

 

 

 

CNPH*6024A**

 

0.98

0.95

 

 

 

315(A,J)AV066135

 

 

 

 

 

 

 

 

 

 

 

CNPV*6024A**

 

0.98

0.95

 

 

 

315(A,J)AV066135

 

 

 

 

 

 

 

 

 

 

 

CSPH*6012A**

 

0.99

0.93

 

 

 

315(A,J)AV066135

 

 

 

 

 

 

 

 

 

 

 

CAP**6024A**

 

0.99

0.93

 

 

 

315(A,J)AV066155

 

 

 

 

 

 

 

 

 

 

 

CNPH*6024A**

 

0.99

0.93

 

 

 

315(A,J)AV066155

 

 

 

 

 

 

 

 

 

 

 

CNPV*6024A**

 

0.99

0.93

 

 

 

315(A,J)AV066155

 

 

 

 

 

 

 

 

 

 

 

CSPH*6012A**

 

 

0.99

0.93

 

 

 

315(A,J)AV066155

 

 

 

 

 

 

 

 

 

 

 

NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.

*Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240---94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.

{Total and sensible capacities are net capacities. Blower motor heat has been subtracted.

}Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh

(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C).

** System kw is total of indoor and outdoor unit kilowatts.

{{At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb. EWB — Entering Wet Bulb

24

Image 24
Contents Industry Leading Features / Benefits Product DataModel Number Nomenclature SeerPhysical Data Unit Size SeriesAccessories Accessory ThermostatsAccessory Usage Guideline ApplicationsOutdoor Air Temperature Sensor Weighted Sound Level DBA Weighted Sound Level DBA with Sound ShieldElectrical Data Charging Subcooling TXV-TYPE Expansion DeviceDimensions 213ANA Balance Point Worksheet Combination Ratings High Temp Low Temp Furnace Model SeriesEnhance Rating 018---A030---A FY4ANF036 036---A 042---A CAP**4221A 40,000 048---A 060---A Detailed Cooling Capacities 525600 675213ANA024---A Outdoor Section With FY4ANF024 Indoor Section 213ANA030---A Outdoor Section With FY4ANF030 Indoor Section 213ANA036---A Outdoor Section With FY4ANF042 Indoor Section 10501200 1350MBtuh† System Total Sens‡ 213ANA042---A Outdoor Section With FY4ANF042 Indoor Section1225 1400213ANA048---A Outdoor Section With FY4ANF048 Indoor Section 16001800 213ANA060---A Outdoor Section With FY4ANF060 Indoor Section 17502000 2250Heat Pump Heating Performance 213ANA018---A Outdoor Section With FY4ANF018 Indoor SectionHeating Indoor Capacity Power Furnace Model 213ANA024---A Outdoor Section With FY4ANF024 Indoor Section213ANA030---A Outdoor Section With FY4ANF030 Indoor Section FX4CNF030 FY4ANF036213ANA036---A Outdoor Section With FY4ANF042 Indoor Section 213ANA042---A Outdoor Section With FY4ANF042 Indoor Section FY4ANF048213ANA048---A Outdoor Section With FY4ANF048 Indoor Section FY4ANB060213ANA060---A Outdoor Section With FY4ANF060 Indoor Section Guide Specifications General Products
Related manuals
Manual 44 pages 21.9 Kb

213A specifications

The Bryant 213A is a cutting-edge system known for its impressive performance and reliability in heating and cooling applications. Designed for residential and light commercial use, it stands out due to its efficiency and innovative features, making it a popular choice among homeowners and contractors alike.

One of the main features of the Bryant 213A is its advanced two-stage cooling and heating capability. This allows for more precise temperature control and enhanced comfort. By adjusting its output based on the current demand, the unit operates at lower speeds during moderate conditions, which helps in saving energy while still maintaining desired comfort levels.

Efficiency is another hallmark of the Bryant 213A. It boasts a high Seasonal Energy Efficiency Ratio (SEER) and Energy Efficiency Ratio (EER), making it one of the most energy-efficient systems in the market. This efficiency not only contributes to lower energy bills but also helps in reducing the environmental footprint of the home, making it a greener choice for those conscious of their energy consumption.

The 213A leverages state-of-the-art technology such as a variable-speed compressor and advanced refrigerant management. This technology facilitates smooth operation and minimizes temperature fluctuations. Additionally, the unit is designed for quiet operation, which means it can efficiently cool or heat a home without intrusive noise, resulting in a more comfortable living environment.

Installation flexibility is another significant advantage of the Bryant 213A. The system is compatible with various ductwork configurations and can be easily integrated into existing HVAC systems. This adaptability makes it suitable for different home sizes and layouts, providing solutions for both new constructions and retrofits.

Durability is a core characteristic of the Bryant 213A. Crafted with high-quality materials and backed by a robust warranty, it ensures longevity and dependable performance. The unit is built to withstand various weather conditions and is designed with low maintenance in mind, further enhancing its appeal.

In conclusion, the Bryant 213A combines efficiency, advanced technology, and durability, making it an exceptional choice for heating and cooling needs. Its innovative features, quiet operation, and adaptability to different home environments set it apart in the HVAC landscape. Selecting the Bryant 213A ensures a comfortable, energy-efficient, and reliable climate control solution for any modern home.