Reassembly | These instructions should be thoroughly |
| read and understood before starting |
| reassembly. |
| General instructions that should be |
| observed to ensure correct reassembly |
| of the pump are as follows: |
| • Using a solvent such as |
| trichloroethane or chloroethene Nu, |
| clean all parts that are to be used in the |
| reassembled pump. |
| WARNING: Use extreme care when using |
| any solvent. Prolonged contact with the |
| liquid or inhalation of the vapor can cause |
| serious health problems. |
| • During and between each of the |
| assembly steps, manually turn the |
| metering gears to ensure that they are |
| free turning. If binding occurs at any time |
| during assembly, determine the cause |
| and correct it before proceeding further. |
| A tiny nick, burr or foreign particle can |
| extensively damage a valuable part if |
| allowed to remain. Never use excessive |
| force in assembling or turning a pump. If |
| properly aligned, the pieces will fit easily |
| into the plate, and the drive shaft will turn |
| freely. All seals, |
| must be replaced with new parts prior |
| to assembly. |
| • Use a |
| pump during reassembly. |
| • Before installing screws, lubricate |
| their threads with DAG Dispersion 154, |
| Felpro |
| lubricant, and torque to prescribed values |
| as shown on the table on page 10. |
| 1) On 3.0 cc/rev and smaller pumps, |
| place a gear key on each shaft and slide |
| each gear onto its shaft, engaging the key. |
| 2) Slide the gear shafts into the center |
| plate, taking care not to damage the gear |
| teeth. On 3.0 cc/rev and smaller pumps, |
| note that each shaft has a larger diameter |
| end. These larger ends must be on oppo- |
| site sides of the pump for the bearing |
| grooves to align properly. |
| 3) Gently slide the gear shafts so that |
| the rear ends of the shafts protrude from |
| the rear of the center plate. On the 3.0 |
| cc/rev and smaller pumps, take care not |
| to slide the shafts out of the gears and |
| allow the keys to drop out of the shafts. |
| 4) Slide a bearing onto the drive shaft, |
| taking special care to select a bearing |
| with the proper groove configuration (and |
| with the proper ID on the 3.0 cc/rev and |
| smaller pumps). Slide the matching bear- |
| ing onto the driven shaft, taking care to |
| select a bearing with the proper groove |
configuration. Set the flats on the circum- ference of the bearings against each other, and gently slide the bearings and shafts into the center plate. Slide them far enough through the center plate to allow the drive shaft to protrude out on the front side and allow the front bearings to be installed. See
5)Install the front bearings in the same manner as the rear bearings, and slide the bearings and shafts back into the center plate so that the gears are roughly in the center of the center plate.
6)For the 20 cc/rev and smaller pumps, the bearings should be allowed to protrude very slightly above the face of the center plate before the cover plates are installed. This will allow the bearings to fit flush against the cover plates as there are no bearing screws on these smaller pumps. For 20 cc/rev and smaller pumps, insert the bearing locating keys on each side.
7)At this point make certain again that there is no foreign matter on the faces of the cover plates or on the faces of the center plate. An accidental smudge of thread lubricant can cause the small pumps to bind.
8)Place the front cover plate on the pump (and center on pump), checking one more time that the configuration of the bearing grooves is correctly oriented for the inlet and discharge ports of the pump. Insert the lubricated cover plate screws into the pump and tighten them finger tight only. Repeat for the rear cover plate.
9)On the 40 cc/rev and larger pumps, insert the bearing retainer screws and tighten them finger tight at this time.
10 Torque down the cover plate screws in a crisscross pattern, taking them first to 1/4 the recommended torque value, then to 1/2, to 3/4 and finally to their full recommended torque value.
11) Torque down the bearing retainer screws in the same manner as the cover plate screws. (Install
12)Fit the Rheoseal seal housing to the shaft. Loosely install but do not torque down the seal housing screws, as this will allow the lip seal to properly center the housing.
13)Install the lip seals, using the special Zenith installation tools as follows to prevent damaging the seal. Install the lip seals with the open face toward the body of the pump. Slide the installation
9