Specifications (Subject to change without notice.)

Input

Rated Output

Welding

Max. Open-

Amps Input at Rated

 

 

 

Net

Power

at 40% Duty Cycle

Amperage Range

Circuit Voltage

Output, 50/60 Hz

KVA

KW

Dimensions

Weight

 

 

 

 

 

 

 

 

 

208-230 V

150 A at 26 V

5 – 200 A

80

54

12.3

6.0

H: 30-1/8 in (765 mm)

238 lb

 

 

 

 

 

 

 

W: 21-1/8 in (537 mm)

(108 kg)

460 V

 

 

 

27

12.52

6.0

 

 

 

D: 21-1/2 in (546 mm)

 

 

 

 

 

 

 

 

 

575 V

 

 

 

22

12.35

6.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Certified to both the Canadian and U.S. Standards for welding equipment.

Control Panel

1

2

3

4

5

6

7

8

9

1. Balance/DIG Pushbutton Control

2. Process Pushbutton Control

3. Power Switch

4. Polarity Switch

5. Voltmeter and Parameter Adjust

6. Ammeter and Parameter Adjust

7. Encoder Adjustment Control

8. Main Amps Pushbutton

(Amperage Control)

9. Pulse Pushbutton Control

Performance Data

DUTY CYCLE CHART

VOLT/AMP CURVES – AC MODE

VOLT/AMP CURVES – DC MODE

 

200

 

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

 

 

150

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

WELD AMPS

 

 

 

 

 

 

 

 

50

100

 

 

 

 

 

 

VOLTS

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

50

20

30

40

50

60

70

80 90 100

0

 

10

 

% DUTY CYCLE

 

AC TIG Min

 

 

 

70

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

50

 

 

 

AC Stick Max

VOLTS

40

 

 

 

 

 

AC Stick Min

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

AC TIG Max

 

10

 

 

 

 

 

0

50

100

150

200

0

 

 

 

AMPERES

 

 

 

 

 

DC Stick Min

 

 

 

 

 

 

(Max DIG)

 

 

 

 

 

 

 

 

 

 

DC Stick Max

 

 

 

 

 

 

(Max DIG)

 

 

DC TIG Min

 

 

DC TIG

 

 

 

 

 

 

 

Max

 

 

0

50

100

150

200

250

300

350

 

 

 

AMPERES

 

 

2

Image 2
Contents Syncrowave Miller Electric Mfg. Co International Headquarters Web SitePerformance Data Duty Cycle Chart VOLT/AMP Curves AC ModeControl Panel Runner Package Genuine Miller AccessoriesRunning Gear and Covers Remote Controls Water Coolant SystemsSyncrowave Runner Ordering InformationComplete Packages