Miller Electric 350 D manual Control Panel, Performance Data

Page 2

Specifications (Subject to change without notice.)

Welding

Output

Weld Output Rated at

Max. Open-Circuit

Single-Phase Generator Power

 

Weight*

Mode

Range

104˚ F (40˚ C)

Voltage DC

Output Rated at 104˚ F (40˚ C)

Dimensions

 

 

 

 

 

 

 

 

 

 

CC/DC

20

– 350 A

300

A, 32

VDC, 100% Duty Cycle

80

12 kVA/KW, 120/240 VAC,

H: 30 in (762 mm)

Net: 998 lb

 

 

 

350

A, 28

VDC, 60% Duty Cycle

 

100/50 A, 60 Hz

W: 24 in (610 mm)

(453 kg)

CV/DC

10

– 34 V

50

 

 

 

 

D: 59-1/2 in (1511 mm)

 

 

 

 

 

 

 

 

 

 

CC/AC

35

– 250 A

200

A, 25

VAC, 60% Duty Cycle

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSA approved.

 

 

 

 

*Net weight with 2 gal of fuel. Add 40 lb for shipping weight.

Engine Specifications (Subject to change without notice.)

 

 

 

 

 

Fuel

Oil

High Coolant Temp/

Engine Brand

Horsepower (HP)

Type

Weld Speed

Idle Speed

Capacity

Capacity

Low Oil Pressure Shutdown

 

 

 

 

 

 

 

 

Kubota DH905

26 at 3600 RPM

3-cylinder,

3600 RPM

2525 RPM

13 gal (49 L)

5.4 qt (5.1 L)

Standard

2-year limited

 

industrial,

 

 

 

 

 

North American

 

liquid-cooled

 

 

 

 

 

Manufacturer

 

diesel

 

 

 

 

 

Warranty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control Panel

1.Voltmeter

2.Ammeter

3.Process/Contactor Switch

4.Voltage/Amperage Adjustment Control

5.Voltage/Amperage Adjust Switch and Remote 14 Receptacle

6.DC Polarity/AC Selector Switch

7.Fuel Gauge

8.Hour Meter

9.Engine Speed Switch

10.Glow Plug Switch

11.Engine Control Switch

12.120/240 V Receptacles Note: GFCIs are standard

1

2

3

4

5

6

7

8

9

10

11

12

Performance Data

FUEL CONSUMPTION DATA

13-gallon fuel capacity.

Welding at 150 A at 40% duty cycle, uses only

.61 gallon per hour — over 20 hours of operation.

7.57

2.00

 

 

 

FUEL CONSUMPTION

 

 

 

 

 

 

 

 

 

 

 

6.62

1.75

 

 

 

 

DC STICK/AUX POWER

 

 

5.67

1.50

 

 

 

 

 

 

 

 

 

 

(HIGH SPEED)

 

 

4.73

1.25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.78

1.00

 

 

 

 

 

 

 

 

 

2.84

0.75

 

 

 

 

DC STICK

 

 

 

 

1.98

0.50

 

 

 

 

 

 

 

 

 

 

 

(LOW SPEED)

 

 

 

0.95

0.25

 

IDLE

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

50

100

150

200

250

300

350

400

LITERS/HR.

GAL/HR.U.S.

 

POWER KVA AT 100% DUTY CYCLE

 

 

 

 

 

DC POWER AMPS AT 100% DUTY CYCLE

 

 

 

0

1

2

4

6

8

10

12

 

2

Image 2
Contents Weld Output Rated at 104˚ F 40˚ C Generator Power Rated at 104˚ F 40˚ CIndustrial Applications Processes Miller Electric Mfg. Co International Headquarters Web SitePerformance Data Engine Specifications Subject to change without noticeControl Panel Power is in the Numbers Rotor StatorPlasma Cutters MIG/Flux Cored Welding Genuine Miller AccessoriesGenuine Miller Options MultioperatorMIG/Flux Cored Welding TIG Gtaw WeldingStick Smaw Welding Trailers and Hitches For both models Mounting SpecificationsTrailer Specifications Subject to change without notice Stick Smaw Basic Equipment TIG Gtaw Basic Equipment ApplicationsMIG Gmaw Basic Equipment Flux-Cored Fcaw Basic EquipmentOrdering Information