EN | NEXUS™ Aw 7x7 QRG |
AC Power This product has an
Power Linking You can link up to 7 NEXUS™ Aw 7x7 products at 120 V, 12 products at 208 V, or 13 products at 230 V. Never exceed this number. Power linking cords can be purchased separately.
Power Linking
Diagram
AC Plug | Connection |
| Wire (U.S.) | Wire (Europe) | Screw Color | |
| AC Live |
| Black | Brown | Yellow/Brass | |
| AC Neutral |
| White | Blue | Silver | |
| AC Ground |
| Green/Yellow | Green/Yellow | Green | |
Replacing the | 1. | Disconnect this product from power. |
| |||
Fuse | 2. | Using a | ||||
|
| the housing. |
|
|
| |
| 3. | Remove blown fuse and replace with a good fuse of the same type | ||||
|
| and rating. |
|
|
| |
| 4. | Screw the fuse holder cap back in place and reconnect power. |
DMX Linking The NEXUS™ Aw 7x7 will work with a DMX controller using a regular DMX serial connection. A DMX Primer is available from www.chauvetpro.com.
DMX Connection The NEXUS™ Aw 7x7 uses a regular DMX data for its DMX personalities: 5, 49, and 54. See the User Manual to connect and configure for DMX operation.
Master/Slave The NEXUS™ Aw 7x7 uses the DMX data connection for its Master/Slave Connection mode. See the User Manual to connect and configure for Master/Slave
operation.