Chauvet INTIMIDATORSCANLED300 Operating Instructions, Using the Control Panel, Menu Map

Page 9

4.OPERATING INSTRUCTIONS

Using the Control Panel

Access control panel functions using the four buttons located directly underneath the LED display on the included wired remote.

BUTTONFUNCTION

<MODE

ESC>

<DOWN>

<UP>

<ENTER>

Used to scroll through the current operating mode, as well as back out of the current menu option

Used to select decreasing advancement in the value

Used to select increasing advancement in the value

Used to select a value and store it to memory

Use the control panel to select the operating mode, as well as the sub-features. For a detailed layout of the control panel functions, please see the “menu map” section on the previous page.

Menu Map

Menu

 

Programming Steps

Description

DMX Mode

d001

 

d001~512

DMX starting address

 

 

 

 

 

NASL

 

 

Standalone Mode

NASL

 

SLAu

 

SoN

Standalone: Slave receive mode

 

 

NStS

 

SrUn

Standalone: Slow

 

 

 

 

 

 

 

NAFA

 

FASt

Standalone: Sound-active

 

Pan Invert

PAN

 

 

rPAN

Pan invert

 

 

 

 

 

 

 

Tilt Invert

tit

 

 

rtit

Tilt invert

 

 

 

 

 

 

 

Display Invert

diS

 

 

rdiS

Invert the display

 

 

 

 

 

 

 

DMX Personality

11CH

 

 

8CH

8-channel DMX personality

 

 

11CH

11-channel DMX personality

 

 

 

 

Reset

 

 

rESt

 

 

Reset all motors to correct any errors with

 

 

 

 

 

motors misaligning during operation

 

 

 

 

 

 

Load Default

 

 

LoAd

 

 

Revert all settings back to the factory

 

 

 

 

 

default

 

 

 

 

 

 

 

Configuring the Starting Address

The Intimidator™ Scan LED 300 fixture uses up to 11 DMX channels. In this DMX configuration/personality, the highest channel that the fixture may be set to in order to function properly is 502. Any address higher than this will prevent access to all of the channels, while in this mode; however, if you desire to use one of the other DMX channels configurations (personalities), please consider the total DMX channels when selecting a DMX address.

The Intimidator™ Scan LED 300 fixture uses 8 or 11 DMX channels, depending on the selected DMX configuration (personality).

Page 9 of 17

Intimidator Scan LED 300 User Manual (Rev. 3)

Image 9
Contents Page Table of Contents Before YOU Begin What Is IncludedUnpacking Instructions Manual ConventionsSafety Instructions Introduction Product Overview Setup AC PowerPower Linking Mounting Configuring the Starting Address Using the Control PanelOperating Instructions Menu MapOperation Master/Slave Mode Sound-Active, Auto ModeDMX Operation Automatic-SlowService Mode Sound-ActiveHidden Menu Map DMX Channel Values CH Mode~180 Appendix General TroubleshootingGeneral Maintenance Returns ProcedureClaims Power Technical SpecificationsWorld Wide Contact US