Cooper Lighting AEL1SD dimensions Architectural Emergency Light Series

Page 1

COOPER LIGHTING - SURE-LITES®

ARCHITECTURAL EMERGENCY LIGHT SERIES

D I E C A S T A L U M I N U M

E m e r g e n c y L i g h t

Dual-voltage input

120/277VAC, 60Hz

• Die cast aluminum housing

with powder coat finish

• Three 6V 6W High output

Xenon lamps

• Sealed Nickel Cadmium

Battery Maintenance Free,

Long Life, Full Recharge

D E S C R I P T I O N

The Sure-Lites Architectural Emergency Light is designed to provide superior illumination while blending into the surrounding space. The housing is constructed of die cast aluminum with an integral refractive polycarbonate lens. The emergency light’s advanced optical design in conjunction with high output Xenon lamps provide maximum path of egress lighting performance. The Sure-Lites Architectural Emergency Light is listed for temperatures between - 20°C and 40°C (-4°F and 104°F) and has silicone gaskets that provide protection from moisture and rain. [Remote unit temperature range: -40°C and 65°C (-40°F and 149°F)] Standard features include Watchguard EMS self-diagnostic system which meets NFPA 101 testing requirements and a FasTest photocell which enables remote testing of the emergency light.

D I M E N S I O N S

107/8”

[276.23mm]

3 7/8”

[98.43mm]

7”

[177.8mm]

S e l f - D i a g n o s t i c s

The self-diagnostic unit will automatically perform all tests required by UL924, and NFPA 101. The system indicates the status of the exit at all times using the LED indicator near the test switch on the side of the unit. A 90 minute battery power (emergency mode) simulation test will occur randomly once every six months.

EMERGENCY LIGHTS Architectural

 

time, 24 Hours

• Watchguard EMS Self-

 

Diagnostic System

Photocell Test Switch

 

(requires accessory LASER

 

for activation)

Universal Pattern

 

Knockouts on rear of

 

housing for direct

E L E C T R I C A L R AT I N G S

 

Rated Wattage to 87 1/2% of Rated D.C. Voltage

Lamp Information

 

 

 

Model

DC Voltage

1 1/2 Hours

Type

Wattage

Number

Spacing1

AEL1SD

6

18

Xenon

6 each

11549423

30.0'

O R D E R I N G I N F O R M AT I O N

mounting to junction box

• UV Stable Polycarbonate

Lens

Line-Latching, Solid-state

Voltage Limited Charger,

Low-Voltage Disconnect,

Brownout Circuit,

Overload/Short Circuit

Protection, Test

Switch/Power Indicator

Light

• UL 924 Listed Self-

Diagnostics, UL Outdoor

Wet Location Listed

(suitable for wet and damp

locations), Life Safety NFPA

101, NEC/OSHA, Most

State and Local Codes

S A M P L E N U M B E R : A E L 1 S D

AEL1

 

 

 

 

 

 

 

Family

Housing

SD=Self Diagnostics

Options

AEL1=Architectural

Finishes

(Standard)

TDM=Time Delay

Emergency

Blank=Silver

 

 

 

Monitor

Light

BK=Black

 

 

 

Remote=Remote

 

BZ=Bronze

 

 

 

Unit

 

WH=White

 

 

 

 

E N E R G Y D ATA

AEL1SD

Input Current (Max.) 120V = .10A

277V = .07A

A E L 1 W H S D

A E L 1 B K S D

Accessories (order separately)

LASER=Key Chain, Red Laser Pointer (activation tested at 15 feet)

A E L 1 B Z S D

602

COOPER LIGHTING

(1)The "Rule of Thumb" spacing guidelines are designed to achieve 1 foot-candle average and 0.1 foot-candle minimum with a 40:1 maximum/minimum ratio. The corridor used is 100 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 8.5 feet. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.

Image 1
Contents AEL1 Architectural Emergency Light Series