Lights
COOPER LIGHTING - SURE-LITES®
INDUSTRIAL & HAZARDOUS LOCATION Emergency
UEL SERIES
U LT I M AT E E M E R G E N C Y L I G H T
E M E R G E N C Y L I G H T I N G
• NEMA 4X, UL50 Listed | |
• | |
| 120/277VAC, 60Hz, Isolation |
| Transformer |
• Die cast aluminum housing | |
• | Powder coat finish |
• UV stable, | |
| polycarbonate, vandal |
| resistant shield (.150” thick) |
| with Torx head tamperproof |
| screws, stainless steel |
• (2) Adjustable 12W, MR16 | |
| lamps |
• | Nickel Cadmium Battery |
• Fully recharged in 24 hours | |
• | Vandal Proof |
• | Watchguard EMS |
|
|
• | Photocell Test Switch |
| (requires accessory LASER |
| for activation) |
• | |
| connectors facilitate |
| installation |
• | UL 924 Listed |
|
|
| Outdoor Wet Location |
| Listed (suitable for wet and |
| damp locations) |
• T1 Haz Lamp Rating |
D E S C R I P T I O ND I M E N S I O N S
The |
|
|
|
|
|
|
Emergency Light is designed for |
|
|
|
|
|
|
those emergency lighting |
|
|
|
|
|
|
applications where ruggedness and |
|
|
|
|
| 15 1/4” |
|
| 6 3/16” |
| |||
dependability are a must. The UEL’s |
|
| [157mm] |
|
| [389mm] |
| ||||||
|
|
|
|
|
| |
|
|
|
|
|
| |
housing is constructed of durable |
|
|
|
|
|
|
die cast aluminum combined with |
|
|
|
|
|
|
the strength of a clear |
|
|
|
|
|
|
polycarbonate shield. Designed for |
|
|
|
| ||
6 11/16” |
|
| ||||
the most severe environments, the | [169mm] |
|
|
| ||
UEL Emergency Light will provide |
|
|
|
|
|
|
maximum performance against |
|
|
|
|
|
|
rain, moisture, cold, corrosives and |
|
|
|
|
|
|
dust. The UEL’s standard features |
|
|
|
| Laser Test | |
include nickel cadmium battery, |
|
|
|
| ||
|
|
|
|
|
| |
|
|
|
|
|
| |
test and MR16 lamps that provide |
|
|
|
|
|
|
the customer with a long life, low |
|
|
|
|
|
|
maintenance, dependable, severe |
|
|
|
|
|
|
environment approved emergency |
|
|
|
|
|
|
lighting unit in those conditions |
|
|
|
|
|
|
when reliability is crucial. The |
|
|
|
|
|
|
injection molded, polycarbonate |
|
|
|
|
|
|
shield provides protection against |
|
|
|
|
|
|
moisture, rain, and vandalism, as |
|
|
|
|
|
|
well. (4) Torx head tamperproof |
|
|
|
|
|
|
screws with |
|
|
|
|
|
|
provide additional |
|
|
|
|
|
|
security. Two adjustable 12W MR16 |
|
|
|
|
|
|
lamps provide maximum path of |
| S e l f - D i a g n o s t i c s |
|
| ||
egress coverage providing a bright, |
|
|
| |||
| The | |||||
even illumination during power |
| |||||
outages. The unique design and |
| tests required by UL924 and NFPA 101. The system |
features make the UEL Emergency | indicates the status of the unit at all times using the | ||
LED indicator near the test switch on the side of the | |||
Light compatible in food | |||
unit. A 90 minute battery power (emergency mode) | |||
processing facilities, outdoor | |||
simulation test will occur randomly once every six | |||
parking garages, | |||
months. | |||
and other indoor/ outdoor severe | |||
A 30 second battery power simulation test will occur | |||
environments. The UEL Emergency | |||
every 30 days. | |||
Light is UL listed for | |||
| |||
to +50°C (+122°F) ambient |
| ||
environments. |
| ||
|
|
| |
|
|
|
E L E C T R I C A L R AT I N G S
| Rated Wattage to 87 1/2% of Rated D.C. Voltage |
| Lamp Information |
|
|
|
| |
Model | DC Voltage | 1 1/2 Hours |
| Type | Wattage | Number | Spacing1 | |
|
|
|
|
|
|
|
|
|
UEL1SD | 12 | 24 |
| MR16 | 12 | 50.0' |
| |
|
|
|
|
|
|
|
|
|
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : U E L 1 S D
• | NSF, National Sanitation |
| Foundation/Splash Zone |
| (for Food Processing) |
• | IP66, Ingress Protection |
| from IEC (International |
| Electrical Commission) |
• | Cleanroom Class 10,000 |
• | Patent Pending |
|
|
|
|
|
|
Family | Housing | ||||
UEL1=Nema 4X | Finishes | ||||
Emergency | Blank=Silver | ||||
Light | BK=Black | ||||
|
|
| WH=White | ||
|
|
| |||
|
|
|
| SD=Self Diagnostics | |
|
|
|
|
| (Standard) |
E n e r g y D a t a
| Input Current (Max.): | |
Model No. | 120V | 277V |
UEL1SD | .09A | .03A |
Options
A=Ammeter
V=Voltmeter
TDM=Time Delay Monitor
HAZ=Hazardous
Locations (Class I,
Division 2, Groups
A, B, C, D)
Accessories (order separately)
LASER=Key Chain, Red Laser Pointer (activation tested at 30 feet)
UXPKA=Pendant Kit Adapter (fitting adapts to 1/2" NPT threaded pendant)
VRSD=#8 Centerpin Torx Screwdriver
658
SPLASH ZONE
COOPER LIGHTING
(1)The "Rule of Thumb" spacing guidelines are designed to achieve 1
The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.0 feet with a lamp head angle of 45 degrees. Cooper Lighting assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.