Important

IMPORTANT!

Please Read Before Starting

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

For safe installation and trouble-free operation,you must:

ÚCarefully read this instruction booklet before beginning.

ÚFollow each installation or repair step exactly as shown.

ÚObserve all local, state, and national electrical codes.

ÚPay close attention to all warning and caution notices given in this manual.

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

This symbol refers to a hazard

or unsafe practice which can

CAUTION result in personal injury or product or property damage.

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.

SPECIAL PRECAUTIONS

When Wiring

……………………………………………………………………

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.

Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.

Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

Ground the unit following local electrical codes.

Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.

When Transporting

……………………………………………………………………

Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers.

When Installing

……………………………………………………………………

…In a Room

Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.

…In Moist or Uneven Locations

Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

…In an area with High Winds

Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

…In a Snowy Area

(for Heat Pump-type Systems)

Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When Connecting Refrigerant Tubing

……………………………………………………………………

Execute enough ventilation in case refrigerant gas leaks during operations. Be careful not to contact the refrigerant gas with the flame. It will cause the generation of poisonous gas.

Keep all tubing runs as short as possible.

Use the flare method for connecting tubing.

Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection.

Check carefully for leaks before starting the test run.

NOTE

Depending on the system type, liquid and gas lines may be either narrow or wide. Therefore, to avoid confusion, the refrigerant tubing for your particular model is specified as either “narrow” or “wide” rather than as “liquid” or “gas”.

When Servicing

……………………………………………………………………

Turn the power OFF at the main power box before opening the unit to check or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the site when finished servicing. Don’t forget to check that no metal scraps or bits of wiring have been left inside the unit.

SM830043

Image 2
Contents Split System AIR Conditioner For safe installation and trouble-free operation,you must Please Read Before StartingWHO should USE this Manual Table of Contents Service Procedures Introduction Read Me First SM830043 Specifications Unit Specifications PerformanceSPW-T303G56 SPW-T303GS56 SPW-T363G56 SPW-T363GS56 SPW-C253G8, C253G8/M SPW-C363G8, C363G8/M SPW-T483G56 SPW-T483GS56 Major Component Specifications Indoor UnitVLT YEL VLT PNK Major Component Specifications Outdoor Unit CompressorModel No SPW-C253G8, SPW-C253G8/M Source Model No SPW-C363G8 SPW-C483G8 SPW-C363G8/M Other Component Specifications Thermistor Room or coil sensorAuxiliary relay Dimensional Data Indoor Unit 25, 30, 36, 48 Type170660 340 940 735 110 380 400 170660 340 940 1235 110 380 400 Refrigerant Flow Diagram Operating Range Specifications Processes and Functions Room Temperature Control Chart Summary and ExplanationsFreeze Prevention Outdoor Fan ControlProcesses and functions Electrical Data Indoor Unit SPW-T253G56, SPW-T363G56, SPW-T483G56Schematic Diagram X363GS Schematic Diagram SPW-T253GS56, SPW-T363GS56, SPW-T483GS56 5268-500-00-1 T253GS56, T363GS56, T483GS56854-2-5268-500-00-1 T253GS56, T363GS56, T483GS56 854-2-5268-501-00-1 T303GS56 RY1 RY4 RY3 Outdoor Unit SPW-C253G5 SPW-C253G5/MOLR SPW-C303G5 SPW-C303G5/M Schematic Diagram SPW-C363G5 SPW-C363G5/M Compressor motor SPW-C253G8 SPW-C253G8/M 47C 63PH 49C 51C 52C SPW-C363G8 SPW-C363G8/M 854-2-5268-459-00-1 C363G8 SPW-C483G8 SPW-C483G8/M 854-2-5268-460-00-1 C483G8 Electrical data Service Procedures Trobleshooting + + + + Power There is a possibility of short circuit Check compressor motor protectors High pressure switch 63PH Check. auxiliary relay Y or 2Y Service procedures Outdoor unit does not run Check compressor motor thermal protector 49C Some part does not operate Indoor fan does not runService procedures Outdoor fan does not run Compressor does not runService procedures Poor cooling Service procedures Excessive cooling Operation of Major Electrical Parts Room temp. Sensor in the remote control unit is defectiveSensor is Defective Indoor heat exchanger coil temp. Sensor is defectiveChecking the Electrical Components Measurement of Insulation ResistanceService procedures Checking the Protective Devices Indoor fan motor FMI Indoor unit Measure the coil resistance Service procedures Fuse on indoor P.C.B. Ass’y Thermistor Characteristic Curve

SPW-C303G5, SPW-T253GS56, SPW-T303GS56, SPW-C363G5, SPW-T303G56 specifications

The Sanyo SPW-C303G5, SPW-T483G56, SPW-C363G8, SPW-C363G5, and SPW-T483GS56 are part of Sanyo's innovative line of high-performance commercial air conditioning systems. These models are engineered for energy efficiency, maximizing comfort while minimizing operational costs.

The SPW-C303G5 stands out with its compact design and powerful cooling capabilities, making it suitable for small to medium-sized commercial spaces. Its inverter technology allows for smooth operation and quiet performance, adjusting the compressor speed to meet the cooling demand effectively. This model also features advanced air filtration systems, which enhance air quality by reducing pollutants and allergens.

In contrast, the SPW-T483G56 is a robust model ideal for larger commercial environments. Its enhanced cooling capacity is complemented by a user-friendly digital control system, allowing precise temperature settings and timer functions. The SPW-T483G56 is equipped with a heat pump feature, enabling both heating and cooling, which significantly increases its versatility.

The SPW-C363G8 and SPW-C363G5 models focus on energy conservation and efficient operation. Both systems utilize eco-friendly refrigerants in line with global environmental standards. The SPW-C363G8 is noted for its enhanced energy efficiency rating, making it an excellent choice for businesses aiming for sustainability. It incorporates advanced heat exchange technology that maximizes energy usage, ensuring lower utility bills.

The SPW-T483GS56 model features an upgraded control interface, allowing users to monitor and adjust settings remotely via a smartphone application. This connectivity empowers users to manage their cooling and heating needs from anywhere, providing increased convenience and ensuring comfort at all times.

All these models share Sanyo's commitment to durability and reliability, with robust construction designed to withstand the rigors of commercial use. Additionally, they come with comprehensive warranties, highlighting Sanyo's confidence in their performance and lifespan. With a combination of cutting-edge technology and user-centered design, the Sanyo air conditioning units provide optimal comfort solutions tailored for diverse commercial applications.