Chicago Electric 93431 Troubleshooting, Problem Possible Causes Likely Solutions

Page 13

Troubleshooting

Problem

 

Possible Causes

 

Likely Solutions

Tool will not start.

1.

Cord not connected.

1.

Check that cord is plugged in.

 

2.

No power at outlet.

2.

Check power at outlet. If outlet is

 

 

 

 

unpowered, turn off tool and check circuit

 

 

 

 

breaker. If breaker is tripped, make sure

 

 

 

 

circuit is right capacity for tool and circuit

 

 

 

 

has no other loads.

 

3.

Internal damage or wear. (Carbon

3.

Have technician service tool.

 

 

brushes or switch, for example.)

 

 

Tool operates slowly.

1.

Excess pressure applied to workpiece.

1. Decrease pressure, allow tool to do the

 

 

 

 

work.

 

2.

Power being reduced by long or small

2.

Eliminate use of extension cord. If an

 

 

diameter extension cord.

 

extension cord is needed, use one with

 

 

 

 

the proper diameter for its length and load.

 

 

 

 

See Extension Cords in GROUNDING

 

 

 

 

section.

Performance

Carbon brushes worn or damaged.

Have qualified technician replace brushes.

decreases over time.

 

 

 

 

Excessive noise or

Internal damage or wear. (Carbon

Have technician service tool.

rattling.

brushes or bearings, for example.)

 

 

Overheating.

1.

Forcing tool to work too fast.

1.

Allow tool to work at its own rate.

 

2.

Blocked motor housing vents.

2.

Wear ANSI-approved safety goggles and

 

 

 

 

NIOSH-approved dust mask/respirator

 

 

 

 

while blowing dust out of motor using

 

 

 

 

compressed air.

 

3.

Motor being strained by long or small

3.

Eliminate use of extension cord. If an

 

 

diameter extension cord.

 

extension cord is needed, use one with

 

 

 

 

the proper diameter for its length and load.

 

 

 

 

See Extension Cords in GROUNDING

 

 

 

 

section.

Tool does not sand

Disc accessory may be damaged, worn or

Check condition and type of disc accessory.

effectively.

wrong type for the material.

Use only proper type of disc accessory in

 

 

 

good condition.

Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.

SKU 93431

For technical questions, please call 1-800-444-3353.

Page 13

Image 13
Contents Random Orbital Palm Sander For technical questions or replacement parts, please callSave This Manual General Power Tool Safety WarningsSave all warnings and instructions for future reference For technical questions, please callIncreased risk of electric shock if your body is grounded Safety Warnings Common for Sanding Operations For technical questions, please call Kickback and Related Warnings Vibration Safety Safety Warnings Specific for Sanding OperationsDouble Insulated Tools Tools with Two Prong Plugs GroundingExtension Cords 25’ 50’ 75’ 100’ 150’ SymbologyTool Set Up SpecificationsUnpacking Instructions for putting Into useGeneral Operating Instructions Work Piece and Work Area Set UpAttaching Sandpaper to the Backing Pad SKU For technical questions, please callCleaning, Maintenance, Lubrication MaintenanceThis power tool is damaged, it must be Replaced only by a qualified serviceProblem Possible Causes Likely Solutions TroubleshootingPart Description Parts ListPart Description Qty Record Product’s Serial Number HereAssembly Diagram Limited 90 DAY Warranty