Bausch & Lomb 78-1600 specifications Changing Power, To Assemble, To USE, Lens Characteristics

Page 2

CHANGING POWER

To change magnification, rotate the Zoom Power Change Ring to the desired power as indicated by the white engraved scale.

As you zoom from low power to high power under low light conditions, you may notice a decrease in image brightness. This is normal. All magnifying optical instruments show a decrease in image brightness as magnification is increased.

3.After setting up, locate the subject through the camera’s viewfinder in the usual way with the spotting scope at it’s lowest magnification. This gives the widest field of view. Once located, you can frame the picture as desired with the Zoom Power Change Ring in the same manner as when using it as a spotting scope, then use the focusing system of the spotting scope to bring the subject into sharp focus. Minimum focus distance as a telephoto lens is 80 feet.

ZOOM TELEPHOTO LENS ADAPTATION FOR SINGLE LENS REFLEX CAMERAS WITH REMOVABLE LENS

Spotting Scope/Telephoto

 

 

 

 

 

 

Telephoto

Adjustment Control

 

 

 

 

Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35mm

SLR

Camera

 

 

 

 

Telephoto

 

 

 

 

Camera Body

Camera Mount

 

 

Adapter

 

 

 

 

 

 

HOW TO USE YOUR DISCOVERER AS A 1000MM TO 4000MM ZOOM TELEPHOTO CAMERA LENS

With the addition of 2 inexpensive accessories, the Discoverer will attach to a 35mm single lens reflex camera that has a removable lens. It then becomes an integral part of the camera’s optical system and functions as an extra powerful zoom lens.

The two accessories needed for this are; a #22-3030 Telephoto Camera Mount and a Camera Body Adapter that matches your particular camera (see listings under accessories at the end of these instructions).

TO ASSEMBLE

1.Turn the spotting scope’s Telephoto Adjustment Control Ring clockwise all the way until it stops, then screw the Telephoto Camera Mount over the eyepiece.

2.Screw the Camera Body Adapter to the other end of the Telephoto Camera Mount.

3.Remove the standard lens from the camera and attach the body to the Camera Body Adapter.

TO USE

1.Films with the highest ISO ratings are recommended. The faster the shutter speed, the sharper your picture.

2.Mount the spotting scope on a sturdy tripod or shooter’s stand. A car window mount is also available but it is recommended that the camera not be operated while the car motor is running since the slightest tremor at even the spotting scope’s lowest magnification can ruin image sharpness. Shield the scope from wind as much as possible and always use a cable release or the camera’s self-timer to make an exposure.

LENS CHARACTERISTICS

Coupling the spotting scope to a camera creates a completely new lens system, the essential characteristics of which are controlled largely by the scope-with one exception: the Discoverer does not incorporate a variable aperture (f/stop) control. In this new system, each of the scope’s 7 power settings has its own effective f/stop as shown on the Telephoto Camera Mount, and any increase or decrease in the amount of light transmitted to the film at any one power setting must be made by a change in the camera’s shutter speed.

HOW TO DETERMINE SHUTTER SPEED

The following reference chart can be used for shutter speeds only under bright, sunlit conditions.

If your camera’s shutter speeds do not match these calibrations and if the difference is very slight, the next higher speed indicated on your camera’s dial should be used. Underexposure in both black and white, and color film (particularly color film) is recommended.

CAMERAS WITH BUILT-IN METERING SYSTEM

Set the camera’s film speed dial to the ISO rating of the film being used. Turn the Zoom Power Ring on the spotting scope to the desired magnification (telephoto effect) and check the chart printed on the Telephoto Camera Mount for matching f/stop, determine the shutter speed in the usual way.If the camera’s meter will not give a reading, increase the film’s ISO setting until it does. Remember to make a note of this higher setting - the laboratory will need to know it when you bring in the film for processing. Also keep in mind that all subsequent pictures on the same roll must be taken at this same ISO rating - roll film cannot be processed by individual frames.

(Continued on page 3) 2

Image 2
Contents Lens Shield FocusingMounting USE with EyeglassesHOW to Determine Shutter Speed Changing PowerLens Characteristics To AssembleReminder AccessoriesWarranty / Repair Lifetime Limited Warranty Questions & Answers

78-1600 specifications

Bausch & Lomb 78-1600 is a notable product in the realm of optical solutions, primarily used for its exceptional performance in vision care. This model stands out for its innovative design and top-tier technologies that cater to the needs of both eye care professionals and patients.

One of the main features of the Bausch & Lomb 78-1600 is its advanced optical system. The device boasts a high-resolution lens that enhances clarity while maintaining color accuracy. This optical precision allows practitioners to conduct thorough examinations, ensuring that they can detect even the slightest irregularities in a patient's vision.

In addition to its optical capabilities, the Bausch & Lomb 78-1600 incorporates state-of-the-art illumination technology. The built-in LED light source provides a bright and even illumination, making it easier for professionals to examine the eye’s structure and function under varying conditions. This feature is particularly beneficial in dimly lit environments or when fine details need to be scrutinized.

Another hallmark of the 78-1600 is its ergonomic design. The device is lightweight and user-friendly, allowing for extended use without discomfort. Eye care professionals will find it easy to maneuver, which can be crucial when working with patients who may have sensitivity or anxiety related to eye examinations.

The 78-1600 also emphasizes versatility. Its adjustable settings allow practitioners to customize the device according to their specific needs and the individual requirements of their patients. This flexibility enhances the overall examination experience and supports accurate diagnosis and treatment.

Durability is another essential characteristic of the Bausch & Lomb 78-1600. Constructed with high-quality materials, the device is designed to withstand the rigors of daily use in clinical settings. This reliability ensures that eye care professionals can depend on the product for consistent performance over time.

Finally, Bausch & Lomb's commitment to quality and innovation is evident in the 78-1600 model. As a respected name in eye care, the brand continually invests in research and technology, making it a trusted choice for professionals looking to provide the highest standard of care to their patients.

In summary, Bausch & Lomb 78-1600 is a standout optical device characterized by its advanced optical system, superior illumination, ergonomic design, versatility, and durability. These features make it an excellent choice for eye care professionals dedicated to delivering effective and compassionate vision care.