Schumacher SCF-2500A owner manual Using the BUILT-IN Battery Tester

Page 10

USING THE BUILT-IN BATTERY TESTER

OVERVIEW

The charger has a built-in battery tester that displays either an accurate battery voltage or an estimate of the battery’s relative charge based on the battery voltage and a scale set by the Battery Council International.

TESTING SEQUENCE

There are four basic steps required to use the charger as a battery tester.

1.Connect the charger battery clamps to the battery. Be sure to follow all of the precautions listed under “OPERAT-

ING INSTRUCTIONS”.

2.Connect the charger power cord to a 120 VAC outlet. Again, be sure to follow all of the precautions listed under “OP-

ERATING INSTRUCTIONS”.

3.If necessary, press the Battery Type button until the correct type is indi- cated.

4.Read the voltage on the digital LED or press the display mode button to set the tester to “Battery %” and read the battery percent.

TESTER AND CHARGER When first turned on, the charger operates only as a tester, not as a charger. To continue to use it as only a tester, avoid pressing the CHARGE RATE switch button. Selecting a charge rate activates the battery charger and deactivates the tester.

POWER-UP IDLE TIME LIMIT

If no switch button is pressed within ten minutes after the unit is first powered up, the unit will automatically switch from tester to charger, if a battery is connected. In that case, the unit will be set for the 2A charge rate and REGU- LAR battery type.

TESTER WITHOUT TIME LIMIT

If either the DISPLAY MODE or BAT- TERY TYPE button is pressed within the first ten minutes after the unit is powered up, the unit will remain a tester (not a charger) indefinitely, unless a charge rate is selected.

TESTING AFTER CHARGING

After the unit has been changed from tester to charger (by selecting a charge rate), it remains a charger as long as it has power. Disconnect and reconnect the power to change the unit back to a tester.

TESTER STATUS LEDs

When the charger is operating as a battery tester, the status LEDs light under the following conditions.

The CHARGED (green) LED will light if a fully charged battery is tested.

The CHARGING (yellow) LED does not light in the battery test mode.

The CHECK (red) LED will light if a battery is not properly connected.

When the tester display mode is set to voltage, none of the Status LEDs light as long as a voltage greater than one volt is detected.

INITIAL PERCENT CALCULATION

When a battery % is calculated for the first time after connecting a battery, the digital LED will show two dashes (“--”) for several seconds while the tester analyzes the battery.

NOTES FOR TESTING BATTERY % A recently charged battery could have a temporarily high voltage due to what is known as “surface charge”. The voltage of such a battery will gradually drop during the period immediately after the charging system is disengaged. Consequently, the tester could display inconsistent values for such a battery. For a more accurate reading, the surface charge should be removed by temporarily creating a load on the battery, such as by turning on lights or other accessories.

The battery % ranges from 0 to 100.

The battery tester is only designed to test 12V batteries. Testing a device with a rapidly changing voltage could yield unexpected or inaccurate results.

10

Image 10
Contents Send Warranty Product Repairs to Table of Contents Important Safety Instructions Help US Help YOUPersonal Safety Precautions Using AN Extension Cord Before Using Your Battery ChargerPreparing Your Battery to be Charged Plugging ITOperating Instructions Charging Battery in the VehicleConnecting to a positive-grounded Negative Grounded SystemCharging Battery Removed From the Vehicle Battery Type Switch SCF-2500A Control Panel Display Mode SwitchCharge Rate Switch Speedcharge ControlSCF-2500A Control Panel Guide Control Panel GuideUsing the BUILT-IN Battery Tester Using Your Battery Charger Know Your Charger Maintenance and CareCharging Tips Battery Percent and Charge Time Troubleshooting Problem Possible Cause SolutionPage Limited Warranty Manuel d’utilisation Faire parvenir les produits à réparer sous garantie àTable DES Matières Utilisation DU Testeur DE Batterie IntégréConservez CES Instructions Consignes DE Sécurité ImportantesAIDEZ-NOUS À Vous Aider N’oubliez pas Mesures DE Sécurité Personnelles Branchement Avant D’UTILISER LE Chargeur DE BatteriePréparer LA Batterie Pour LA Charge Utilisation D’UNE RallongeCharge DE LA Batterie Dans LE Compartiment Moteur Consignes D’UTILISATIONCircuit À Masse Négative Charge DE LA Batterie Hors DU Véhicule OrdinaireCommutateur DE Taux DE Charge Tableau DE Commande DU ChargeurCommutateur DE Type DE Batterie Guide Tableau DE Commande Tableau DE Commande DU Modèle SCF-2500AUtilisation DU Testeur DE Batterie Intégré Page Utilisation DU Chargeur DE Batterie Conseils Pour LA Charge SE Familiariser Avec LE ChargeurEntretien Pourcentage ET Temps DE Charge Tableau DE Dépannage Anomalie Cause Probable CorrectifGarantie Limitée