11.5Press the CHARGE VOLTAGE button to select the correct battery voltage of either 6V or 12V.

11.6Press the CHARGE MODE button to select the correct battery type and charge rate:

FAST: 35 minute charge for automotive and marine batteries. Maximum charge rate for large batteries that can accept up to 80 Amps of charging current.

FULL: Up to 240 minute charge for automotive and marine batteries. Maximum charge rate for large batteries that can accept up to 80 Amps of charging current.

FULL (lawn tractor, motorcycle, ATV): Up to 240 minute charge. Lower charge rate for small batteries.

GEL FAST/FULL: Up to 240 minute charge. Charge rate safe for all Gel Cell batteries.

11.7Press the CHARGE ON/OFF button to start the charge cycle.

11.8After pressing the button, the display shows the selected charge mode on the top line and the time remaining (counting down) on the bottom line.

If the display shows “Connect Battery” even when a battery is properly connected to the INC-800A, the battery is below 0.2V. The automatic charger will not start. If you would like to start manually, press and hold the CHARGE ON/OFF button for 5 seconds until the charge cycle starts.

11.9If you are using the FULL (240 minute charge) mode, the Charge Remain- ing timer counts down to 0 minutes, or the battery becomes fully charged, the charge cycle will be complete. The CHARGED (green) LED will light, the charger will beep four times and the charger will go into Maintain

Mode. If you are using the FAST (35 minute charge) mode the Charge Re- maining timer will count down to 0 minutes, the CHARGED (green) LED will light and the charger will beep four times, but the battery may not be fully charged. If left alone, the charger will continue to charge the battery until it is fully charged then go into maintain mode.

11.10Press the CHARGE ON/OFF button before disconnecting clips.

Aborted Charge

If charging can not be completed normally, charging will abort. When charging aborts, the charger’s output is shut off, and the display shows CHARGE ABORTED on the top line and BAD BATTERY on the bottom line. It will also beep four times to let you know. NOTE: In the case of a severely discharged battery, the charger will go into abort mode. If, after the output turns off, the battery voltage drops to under .2 volts, the charger will reset to the default settings and the display will show 12V FAST on the top line and CONNECT BATTERY on the bottom line.

Desulfation Mode See Aborted Charge.

7

Image 10
Contents Model INC-800A Page Table of Contents Important Safety Instructions Preparing to Charge DC Connection Precautions Charger LocationPage Battery charging ac connections Grounding MethodsAssembly instructions Control panel Operating instructionsDesulfation Mode See Aborted Charge Aborted ChargeCompletion of Charge Maintain ModeMaintenance instructions General Charging NotesTroubleshooting Problem Possible Cause REASON/SOLUTIONBefore Returning For Repairs Limited warranty Page Page Modelo INC-800A Page Sección Pàgina Instrucciones DE Seguridad Importantes Precauciones Personales PREPARación de la cargaUbicación DEL Cargador Precauciones DE LA Conexión CCSiga Estos Pasos cuando la batería esté afuera del vehículo Píes m Bateria Cargando Conexiones ACCalibre Instrucciones DE Ensamblaje Panel DE Control Instrucciones DE Operación Carga Abortada Modo de Desulfatar Vea Carga AbortadaNotas Generales Sobre la Carga Completación de CargaModo de Mantenimiento Instrucciones DE MantenimientoSolución DE Problemas Problema Causa Posible SolucionProblema Causa Posible Solucion Antes DE Devolver EL Cargador Para Reparación