INTRODUCTION
These dispensers are designed to mix liquid tea concentrate with water to produce iced tea by the glass or pitcher. The concentrate can be stored either inside the dispenser, or outside with a hose connection to the dispenser. The dispenser must be placed on a sturdy counter or shelf.
PLUMBING REQUIREMENTS
This dispenser must be connected to a cold water system with operating pressure between 30 and 90 psi (138 and 620 kPa) from a 1⁄2" or larger supply line. A
NOTE -
As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to comply with federal, state and local codes. For models installed outside the U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area.
USER NOTICES
Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels.
As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to comply with federal, state and local codes. For models installed outside the U.S.A., you must comply with the applicable Plumb- ing /Sanitation Code for your area.
00656.0001
WARNING
FAUCET UNDER PRESSURE
Shut off water before cleaning. Use only BUNN approved faucet part #03260.0004 (Plastic Body Faucet, Locking Handle), #03260.0009 (Plastic Body Faucet,
38130.0000D 07/07 © 2005
38130.0000
PRESSURE REGULATOR ADJUSTMENT
1.Pull Knob out to unlock.
2.Adjust to 20 psi while faucet is open, dispensing product.
3.Push knob in to lock.