7. ELECTRICAL DATA

Electrical Characteristics CMH1822 / KMH0922 (1)

Performance at

 

 

Indoor Unit

 

 

Outdoor Unit

 

 

Complete Unit

230/208V – 1ø – 60Hz

 

Fan Motor

Max. Heat

 

Fan Motor

Compressor

Heat-pump

Max. Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Rating

A

0.15

/ 0.14

 

0.52

/ 0.52

3.43

/ 3.64

4.1

/ 4.3

Conditions

W

34

/ 29

 

116

/ 104

750

/ 737

900

/ 870

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

 

Rating

A

0.15

/ 0.14

4.35 / 3.93

 

0.52

/ 0.52

3.43

/ 3.64

4.1

/ 4.3

8.45 / 8.23

Conditions

W

34

/ 29

1,000 / 818

 

116

/ 104

750

/ 737

900

/ 870

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Locked-Rotor Amperes

A

0.19

/ 0.18

 

0.71

/ 0.64

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remarks:

Rating conditions are:

 

 

 

 

 

 

 

 

 

 

 

 

Cooling: Outside air temperature 95°F DB/75°F WB

 

 

 

 

 

 

 

 

 

Indoor unit entering air temperature 80°F DB/67°F WB

 

 

 

 

 

 

 

Heating: Outside air temperature 47°F DB/43°F WB

 

 

 

 

 

 

 

 

 

Indoor unit entering air temperature 70°F WB

 

 

 

 

 

 

CMH1822 / KMH0922 (2)

Performance at

 

 

Indoor Unit

 

 

Outdoor Unit

 

 

Complete Unit

230/208V – 1ø – 60Hz

 

Fan Motor

Max. Heat

 

Fan Motor

Compressor

Heat-pump

Max. Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Rating

A

0.30

/ 0.28

 

0.52

/ 0.52

7.38

/ 7.90

8.2

/ 8.7

Conditions

W

68

/ 58

 

116

/ 104

1,636

/ 1,618

1,820

/ 1,780

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

 

Rating

A

0.30

/ 0.28

8.70 / 7.86

 

0.52

/ 0.52

6.68

/ 7.10

7.5

/ 7.9

16.2 / 15.76

Conditions

W

68

/ 58

2,000 / 1,636

 

116

/ 104

1,456

/ 1,428

1,640

/ 1,590

3,640 / 3,226

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Locked-Rotor Amperes

A

0.19 2 / 0.18 2

 

0.71

/ 0.64

27 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remarks:

Rating conditions are:

 

 

 

 

 

 

 

 

 

 

 

 

Cooling: Outside air temperature 95°F DB/75°F WB

 

 

 

 

 

 

 

 

 

Indoor unit entering air temperature 80°F DB/67°F WB

 

 

 

 

 

 

 

Heating: Outside air temperature 47°F DB/43°F WB

 

 

 

 

 

 

 

 

 

Indoor unit entering air temperature 70°F WB

 

 

 

 

 

 

10WM – 700700

Image 15
Contents Split System AIR Conditioner Page CMH1822 / KMH0922 ⋅2 Basic Information Please Read Before Starting Table of Contents CMH1822 / KMH0922 ⋅2 Operating RangeSpecifications Applicable Indoor Unit Dimensional Data Outdoor Unit CMH1822Indoor Unit KMH0922 230V CMH1822 / KMH0922 ⋅1 Cooling Capacity208V CMH1822 / KMH0922 ⋅1 Heating Capacity Phase 60Hz 230V Model Name CMH1822 / KMH0922 ⋅1Phase 60Hz 208V Model Name CMH1822 / KMH0922 ⋅1 Refrigerant Flow Diagram Cooling CycleHeating Cycle Electrical Data Electrical Characteristics CMH1822 / KMH0922 ⋅1To avoid electrical shock hazard, be sure to Outdoor Unit H407/12M