Hitachi C6DD manual Regarding electric discharge in case of new batteries, etc

Page 16

Table 1

Indications of the pilot lamp

Before charging

While charging

Charging complete

Charging impossible

Charging impossible

Blinks

Lights for 0.5 seconds. Does not light for 0.5

(RED)

seconds. (off for 0.5 seconds)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lights

Lights continuously

(RED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinks

Lights for 0.5 seconds. Does not light for 0.5

(RED)

seconds. (off for 0.5 seconds)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flickers

Lights for 0.1 seconds. Does not light for 0.1

(RED)

seconds. (off for 0.1 seconds)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lights

Lights continuously

(GREEN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Malfunction in the battery or the charger

The battery temperature

is high, making recharging impossible.

(2)Regarding the temperatures of the rechargeable battery.

The temperatures for rechargeable batteries are as shown in the table below, and batteries that have become hot should be cooled for a while before being recharged.

Table 2 Recharging ranges of batteries

 

Temperatures at

Rechargeable batteries

which the battery

 

can be recharged

EB1814. EB18B. EB1820

–5°C

60°C

EB1830H

0°C –

45°C

(3)Regarding recharging time

Depending on the combination of the charger and batteries, the charging time will become as shown in Table 3.

Table 3 Charging time (At 20°C)

Charger

Battery

UC24YFA

 

 

 

EB1814

Approx. 40

min.

EB18B, EB1820

Approx.

50

min.

EB1830H

Approx.

70

min.

NOTE

The charging time may vary according to temperature and power source voltage.

4.Disconnect the charger’s power cord from the receptacle.

5.Hold the charger firmly and pull out the battery.

NOTE

After operation, pull out batteries from the charger first, and then keep the batteries properly.

Regarding electric discharge in case of new batteries, etc.

As the internal chemical substance of new batteries and batteries that have not been used for an extended period is not activated, the electric discharge might be low when using them the first and second time. This is a temporary phenomenon, and normal time required for recharging will be restored by recharging the batteries 2 – 3 times.

How to make the batteries perform longer.

(1)Recharge the batteries before they become completely exhausted.

When you feel that the power of the tool becomes weaker, stop using the tool and recharge its battery. If you continue to use the tool and exhaust the electric current, the battery may be damaged and its life will become shorter.

(2)Avoid recharging at high temperatures.

A rechargeable battery will be hot immediately after use. If such a battery is recharged immediately after use, its internal chemical substance will deteriorate,

and the battery life will be shortened. Leave the battery and recharge it after it has cooled for a while.

CAUTION

If the battery is charged while it is heated because it has been left for a long time in a location subject to direct sunlight or because the batetery has just been used, the pilot lamp of the charger lights up green. In such a case, first let the battery cool, then start charging.

When the pilot lamp flickers in red (at 0.2-second intervals), check for and take out any foreign objects in the charger’s battery installation hole. If there are no foreign objects, it is probable that the battery or charger is malfunctioning. Take it to your authorized Service Center.

Since the built-in micro computer takes about 3 seconds to confirm that the battery being charged with UC24YFA is taken out, wait for a minimum of 3 seconds before reinserting it to continue charging.

15

Image 16
Contents Page Page Page 11.5 mm Page Page Page Page Page Page Page Page General Operational Precautions Precautions on Using Cordless Circular SAWSpecifications KickbackStandard Accessories Battery REMOVAL/INSTALLATIONApplication ChargingHow to make the batteries perform longer Regarding electric discharge in case of new batteries, etcHOW to USE Adjusting the SAW Prior to USEPrior to Operation Mounting and Dismounting the SAW Blade Maintenance and InspectionReplacing Light Bulb Performance checkup and maintenance of safety cover Service and repairsService parts list a Item No Replacing carbon brushesPage 6001VVCMPS2L 203