Fujitsu ABU22, ABO22 Energy Save Operation, Manual Auto Operation, About the Energy Save

Page 13

ENERGY SAVE OPERATION

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

The air conditioner can be operated while keeping energy consumption costs down.

How To Use the ENERGY SAVE OPERATION

1

Press the START/STOP button

(if the unit is already operating, proceed to step 2).

The indoor unit’s OPERATION indicator light (red) will turn on.

SET SWING SET SWING

TIME TEST

ENERGYADJUST RUN ACL

SAVE

2

Press the MASTER CONTROL button to select the

 

COOL, DRY, *HEAT mode.

 

3

Press the ENERGY SAVE button.

To Cancel the ENERGY SAVE:

Press the ENERGY SAVE button.

ENERGY SAVE can only be used if the MASTER CONTROL button is used

 

to select the “COOL”, “DRY” or *“HEAT”.

About the ENERGY SAVE

The air conditioner saves energy costs by controlling the thermostat temperature setting.

*During Heating operation:

The thermostat temperature setting decreases by 2 °F as soon as the ENERGY SAVE button is pressed, and then de- creases by another 2 °F every thirty minutes.

In this manner, energy is saved by continuing to heat at a thermostat temperature of 8 °F below the setting.

ENERGY SAVE setting

During Cooling/Dry operation:

The thermostat temperature setting increases by 2 °F as soon as the ENERGY SAVE button is pressed, and then increases by another 2 °F after one hour has passed.

In this manner, energy is saved by continuing to cool or dry at a thermostat temperature of 4 °F above the setting.

ENERGY SAVE setting

 

2 °F

4 °F

6 °F

8 °F Set temperature

1 hour

 

 

 

 

 

 

ENERGY

 

 

 

 

 

 

SAVE ON

 

ENERGY

30 minutes

 

 

 

2 °F

4 °F

SAVE ON

 

 

 

 

 

 

 

Set temperature

 

 

 

 

 

 

 

 

 

 

 

1 hour

1 hour 30 minutes

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is lost or otherwise unavailable.

How To Use the Main Unit Controls

Press the MANUAL AUTO button on the main unit control panel.

To stop operation, press the MANUAL AUTO button once again.

When the air conditioner is operated with the controls on the Main unit, it will operate under the same mode as the AUTO mode selected on the re- mote control unit (see page 8).

The fan speed selected will be

“AUTO” and the thermostat setting will be 74 °F.

En-13

Image 13
Contents Operating Manual Safety Precautions ContentsAutomatic Operation Features and FunctionsEn-4 Name of PartsOutdoor Unit Intake Side D Outlet Side E Pipe Unit Time Adjust Button R Test RUN ButtonPreparation Operation To Select Mode Operation Press the START/STOP buttonTo Set the Thermostat Press the SET TEMP. buttons To Set the Fan Speed Press the FAN Control buttonAbout Mode Operation Timer Operation About the Program timer Sleep Timer OperationAbout the on timer About the Sleep timerTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationExample When set to horizontal air di RectionTo Stop Horizontal airflow Swing Operation Swing OperationAbout Swing Operation Air flow direction set Range of swingManual Auto Operation Energy Save OperationAbout the Energy Save Clean the air filters Cleaning and CarePull the air filters upward to remove them Re-attach the air filters to the intake grilleSymptom Problem TroubleshootingEn-16 Event of Power Interruption Temperature and Humidity RangeOperating Tips Auto Restart800 888-FGAI

ROOM AIR CONDITIONER, ABU22, ABO22 specifications

The Fujitsu ABO22 and ABU22 ROOM AIR CONDITIONERS represent the pinnacle of modern cooling technology, designed to provide efficient, reliable climate control for both residential and commercial spaces. These models are characterized by their combination of advanced features, energy efficiency, and user-friendly operation, making them ideal choices for consumers seeking comfort and performance.

One of the standout features of the Fujitsu ABO22 and ABU22 is their energy efficiency. Both models are equipped with inverter technology, which allows for variable speed operation. This technology adjusts the compressor speed based on the cooling demand, leading to significantly reduced energy consumption compared to traditional air conditioning units. This not only lowers electricity bills but also contributes to a more sustainable environment by minimizing carbon emissions.

In terms of cooling performance, these air conditioners provide rapid cooling capability, ensuring that spaces reach the desired temperature quickly. The units come with multi-stage filtration systems that effectively trap dust, allergens, and pollutants, improving indoor air quality. This is particularly beneficial for allergy sufferers and those with respiratory issues, as clean air is essential for overall health.

User convenience is a key consideration in the design of the ABO22 and ABU22. Both units feature intuitive remote control options, allowing users to easily set parameters and adjust settings from anywhere in the room. Additionally, the models offer programmable timers and modes, including sleep mode and eco-mode, which further enhance comfort and efficiency.

Quiet operation is another characteristic of the Fujitsu ABO22 and ABU22. These air conditioners are designed to operate at lower noise levels, allowing users to enjoy a peaceful environment whether they are working, sleeping, or entertaining. This is particularly important in residential settings where noise can be a significant concern.

Moreover, the compact design of these units ensures easy installation and versatility, fitting seamlessly into various room layouts. With a sleek and modern aesthetic, they can complement different interior styles, making them a fashionable addition to any space.

Overall, the Fujitsu ABO22 and ABU22 ROOM AIR CONDITIONERS stand out for their energy efficiency, advanced air purification technologies, quiet operation, and user-friendly features, making them an excellent investment for enhanced indoor comfort. Whether for home or business, these air conditioners promise reliable and effective temperature control year-round.