Central Cluster Arrays

Small Venue, with Very-Wide Coverage

Full-range cabinets:

6 (Xcn)

MB/HF cabinets:

none

LF cabinets:

4 (Xcb)

Subwoofer cabinets:

2 (Xds)

Horizontal Coverage:

130 to 180 degrees

Pattern:

Symmetrical

Amplifier channels:

12 channels

Total Power:

12,400 W

Xcn

 

Xcn

Xcn

40x60

Xcb

40x60 Xcb

40x60

Xcn

Xcb

Xcn

Xcb

Xcn

40x60

40x60

40x60

 

 

(Array H1)

Xds

 

Xds

 

 

 

 

 

Small Venue, with Very-Wide Coverage

Full-range cabinets:

6 (Xn)

MB/HF cabinets:

none

LF cabinets:

4 (Xb)

Subwoofer cabinets:

2 (Xds)

Horizontal Coverage:

130 to 180 degrees

Pattern:

Symmetrical

Amplifier channels:

17 channels

Total Power:

16,400 W

Xn

Xn

Xn

60x40

Xb 60x40

Xb 60x40

Xn

Xb

Xn

Xb

Xn

60x40

 

60x40

 

60x40

XdsXds

(Array I1)

Other Central Cluster Arrays

The following arrays are recommended for the central-cluster applications:

Application

Recommended Array

 

 

very-small venue, wide coverage angle ........................ F1

small venue, narrow coverage angle

J1

small venue, wide coverage angle

F2

small venue, wide coverage angle

G1

small venue, very-wide coverage angle

H1

small venue, very-wide coverage angle ......................... I1

medium venue, narrow coverage angle ........................ J2

medium venue, medium coverage angle

B1

large venue, medium coverage angle

B2

 

 

 

Please refer to the previous sections for illustrations of the arrays.

For central cluster applications, only one channel of the illustrated stereo-pair array.

1 0

Image 10
Contents Array Concert Systems Page Table of Contents Very-Small Venue with Wide Coverage Angle Theatre Medium Venue with Narrow Coverage Angle LargeTheatre Medium Venue with Narrow Coverage Angle Small AmpitheaterMedium Venue with Wide Coverage Angle Small Ampitheater Large Venue with Narrow Coverage Angle Large Ampitheater Large Venue with Medium Coverage Angle Large AmpitheaterFull-range cabinets 12 Xcn MB/HF cabinets 12 Xf Large Venue with Wide Coverage Angle Small ArenaLarge Venue with Very-Wide Coverage Angle Small Arena LF cabinets 12 Xb, 4 XcbSubwoofer cabinets 12 Xds Large Venue with Wide Coverage Angle Large ArenaLarge Venue with Very-Wide Coverage Angle Large Arena Horizontal Coverage 135 to 180 degreesFull-range cabinets 20 Xcn MB/HF cabinets 12 XfOther Central Cluster Arrays Small Venue, with Very-Wide CoverageApplication Recommended Array Page Cecil Street, Buchanan, MI