Cisco Systems AIR-CAP702I-x-K9 specifications Mounting the Access Point

Page 10

e.If the operating system download is successful, the access point reboots.

Step 3 Configure the access point if required. Use the controller CLI, controller GUI, or Cisco Prime Infrastructure to customize the access-point-specific 802.11n network settings.

Step 4 If the pre-installation configuration is successful, the Status LED is green indicating normal operation. Disconnect the access point and mount it at the location at which you intend to deploy it on the wireless network.

Step 5 If your access point does not indicate normal operation, turn it off and repeat the pre-installation configuration.

Note When you are installing a Layer 3 access point on a different subnet than the Cisco wireless LAN controller, be sure that a DHCP server is reachable from the subnet on which you will be installing the access point, and that the subnet has a route back to the Cisco wireless LAN controller. Also be sure that the route back to the Cisco wireless LAN controller has destination UDP ports 5246 and 5247 open for CAPWAP communications. Ensure that the route back to the primary, secondary, and tertiary wireless LAN controller allows IP packet fragments. Finally, be sure that if address translation is used, that the access point and the Cisco wireless LAN controller have a static 1-to-1 NAT to an outside address.

8Mounting the Access Point

Cisco Aironet 700 series access points can be mounted in several configurations, including on a suspended ceiling, on a hard ceiling or wall, on an electrical or network box, and above a suspended ceiling. Click this URL to browse to complete access point mounting instructions:

http://www.cisco.com/en/US/docs/wireless/access_point/mounting/guide/apmount.html

9Deploying the Access Point on the Wireless Network

After you have mounted the access point, follow these steps to deploy it on the wireless network:

Step 1 Connect and power up the access point.

Step 2 Observe the access point LED (for LED descriptions, see “Checking the Access Point LED” section on page 11).

a.When you power up the access point, it begins a power-up sequence that you can verify by observing the access point LED. If the power-up sequence is successful, the discovery and join process begins. During this process, the LED blinks sequentially green, red, and amber. When the access point has joined a controller, the LED chirps green if no clients are associated or stays green if one or more clients are associated.

b.If the LED is not on, the access point is most likely not receiving power.

c.If the LED blinks sequentially for more than 5 minutes, the access point is unable to find its primary, secondary, and tertiary Cisco wireless LAN controller. Check the connection between the access point and the Cisco wireless LAN controller, and be sure the access point and the Cisco wireless LAN controller are either on the same subnet or that the access point has a route back to its primary, secondary, and tertiary Cisco wireless LAN controller. Also, if the access point is not on the same subnet as the Cisco wireless LAN controller, be sure that there is a properly configured DHCP server on the same subnet as the access point. See the “Configuring DHCP Option 43 and DHCP Option 60” section on page 23 for additional information.

Step 3 Reconfigure the Cisco wireless LAN controller so that it is not the Master.

Note A Master Cisco wireless LAN controller should be used only for configuring access points and not in a working network.

10

Image 10
Contents Cisco Aironet 700 Series Access Points Safety Instructions Introduction to the Access PointAbout this Guide 20A. Statement Access Point Ports and Connectors ConfigurationsUnpacking Access Point LED Indicator top Configuring the Access Point Access Point Ports and Connections bottomController Discovery Process Performing a Pre-Installation Configuration Preparing the Access PointInstallation Summary Pre-Installation Configuration SetupController Layer 3 devices Cisco Aironet access points Mounting the Access Point Deploying the Access Point on the Wireless NetworkUsing Dhcp Option TroubleshootingChecking the Access Point LED Troubleshooting the Access Point Join Process Declarations of Conformity and Regulatory Information ModelsVcci Statement for Japan USAJapanese Translation Statement 371-Power Cable and AC AdapterEnglish Translation Industry Canada Canadian Compliance Statement French TranslationModels Declaration of Conformity for RF Exposure Generic Discussion on RF Exposure This Device Meets FCC Guidelines for Exposure to Radio WavesAdditional Information on RF Exposure Chinese Translation English Translation Chinese Translation English Translation Access Point Models Configuring Dhcp Option 43 and Dhcp OptionOperation of Cisco Aironet Access Points in Brazil Declaration of Conformity StatementsAccess Point Specifications Add the option 60 line using the following syntaxObtaining Documentation and Submitting a Service Request