Sharp AF-R120CX, AF-R100CX, AF-R140CX Precautions, Always use a fuse with the proper amp rating

Page 8

PRECAUTIONS

CAUTION FOR USE

IMPORTANT: Points to keep in mind when using your air conditioner.

Install the air conditioner by following the installation instructions given in the previous section of this manual.

Make sure the unit is the correct capacity for the area you want to cool.

Do not modify any part of this product.

Do not insert objects into any part of the unit.

Push the AC power plug securely into the receptacle and make sure it is not loose.

Use power circuit with a proper voltage rating.

Use a three-pronged grounded electrical outlet rated 125V, 60Hz, 15 amp or more, AC only as shown on right.

Use of an improper voltage rating power circuit can result in

damage to the unit and possibly fire.Two-Pole, 3-wire Grounding Receptacle 15 Amps. 125V.

Always use a fuse with the proper amp rating.

Do not, under any circumstances, use wire, pins or other objects in place of the proper fuse.

Use of extension cords of any kind is not recommended.

If you still elect to use an extension cord, it is absolutely necessary that it be a UL Listed 3-wire grounding type appliance extension cord rated 125 Volts, 15 amp or more.

Ventilate the room periodically during use, especially if using gas appliances.

GROUNDING INSTRUCTIONS

WARNING: Improper use of the grounding plug can result in the risk of electric shock.

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.

This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.

WARNING: Do not under any circumstances cut or remove the round grounding prong from this plug.

If it is necessary to use an extension cord, use only a UL Listed 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the appliance.

The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more.

Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.

If a grounding adapter is used, make sure the receptacle box is fully grounded.

3-Pronged receptacle

3-Pronged plug

Grounding prong

Grounding adapter

Grounded receptacle box

Screw

Tab for grounding screw

Grounded receptacle box

Grounding wire

8

Image 8
Contents AF-R100CX AF-R120CX AF-R140CX Accessories Additional Customer Information For Your ProtectionConsumer Limited Warranty Consumer Limited WarrantyLocation Installation InstructionsCheck Window Area Suggested Tools InstallationItems Packed with this Unit Front panel. Keep them as they will Secure the cabinet to the window Precautions Always use a fuse with the proper amp ratingEnergy Efficiency Tips Parts Names UnitHOW to Operate To Change Temperature SettingPower Cooling OperationTo Change FAN Speed FAN only OperationEnergy Saver To Change AIR Flow DirectionExhaust Energy SaverOn Timer Operation Touch the Timer onTimer Delayed start timeOFF pad to set OFF Timer OperationDelayed stop time Using the Remote Control Use two size-AAA R03 batteriesPower on / OFF button Temperature setting buttonSET Timer / OFF button TransmitterCleaning and Maintenance Remove the FilterTimer does not Work Properly If the Unit Fails to Receive the Remote Control SignalAIR Conditioner does not Operate AT ALL AIR Conditioner does not Properly CoolSharp Electronics Corporation

AF-R120CX, AF-R140CX, AF-R100CX specifications

The Sharp AF-R140CX, AF-R120CX, and AF-R100CX are part of Sharp's innovative lineup of air conditioning units designed to provide efficient cooling and heating solutions for residential and commercial spaces. These models stand out for their advanced features, energy-efficient technologies, and user-friendly design, making them ideal choices for maintaining a comfortable indoor climate.

One of the key characteristics of the AF-R series is its powerful cooling and heating capabilities. With cooling capacities range from 10,000 to 14,000 BTU/h, these units can effectively manage temperatures in medium to large spaces. The AF-R140CX, being the most robust of the trio, delivers exceptional performance, while the AF-R120CX and AF-R100CX offer slightly reduced capacities suitable for smaller areas.

All models in this series incorporate Sharp’s innovative Plasmacluster Technology, which not only cools or heats the air but also purifies it. This technology releases ions that help to neutralize harmful airborne particles, including allergens, bacteria, and mold, ensuring that the air in your home is not just comfortable but also healthy.

Energy efficiency is another hallmark of the Sharp AF-R series. Each model is equipped with an inverter compressor that automatically adjusts the cooling or heating output based on the room’s requirements. This feature not only helps maintain a consistent temperature but also significantly reduces energy consumption, resulting in lower electricity bills.

User convenience is prioritized in the design of these air conditioning units. They come with a remote control, allowing for easy operation from anywhere in the room. Some models also feature a programmable timer that enables users to set specific cooling or heating schedules, enhancing both comfort and energy savings.

Furthermore, the AF-R series is designed with a sleek, modern aesthetic that fits seamlessly into any interior decor. Their compact size makes installation straightforward, and the units operate quietly, contributing to a peaceful environment.

Overall, the Sharp AF-R140CX, AF-R120CX, and AF-R100CX models exemplify the fusion of style, efficiency, and advanced technology, making them top contenders in the air conditioning market. Users can expect reliable performance, clean air, and significant energy savings, ensuring a comfortable living or working environment year-round.