HP manual Introduction to the 37717C Front Panel, Start/ stop test

Page 9

Getting Started

Introduction to the 37717C Front Panel

Introduction to the 37717C Front Panel

Select display

Received signal and alarm condition

TRANSMIT

RECEIVE

RESULTS

Start/ stop test

LOS

PATTERN LOSS

ERRORS

AISPDH/DSn

FRAME LOSS M/F LOSS REMOTE ALARM REMOTE M/F ALARM

FRAME LOSS SDH/SONET LOSS OF POINTER MS-AIS

AU-AIS

CLOCK LOSS

MS-RDI

HP-RDI

TU-AIS

GRAPH

RUN/

VP ALARM ATM VC ALARM

LP-RDI

POINTER ADJUST

STOP

OTHER

LOSS OF CELL SYNC SELECTED CELL NOT RX JITTER UNLOCK JITTER HITS

HISTORY

SHOW RESET

HISTORY HISTORY

SET

Control pop up menu

CANCEL

Manual printer/ logging controls

PAPERPRINT

FEEDNOW

Move cursor

The operator interface is provided by the display and the front panel keys.

The display may be multiple windows or a single window.

When the display is multiple windows, the "active" window is indicated with a color which is different from the color of the three "inactive" windows.

7

Image 9
Contents HP 37717C Communications Performance Analyzer Documentation Warranty HP 37717C Communications Performance Analyzer About This Book Contents Contents Getting Started Transmit Receive Results Graph Other Start/ stop test Introduction to the 37717C Front PanelSelecting Displays Selecting Multiple or Single Windows Graph and Other , to select the display requiredThen press Moving Around Multiple Windows Selecting the Graph or Other Display in Multiple Windows Selecting Displays Changing the Displayed Folder ExampleUse Changing the Instrument Settings When More is chosen the remainder of the menu is revealed Modifying Displays with Pop-up Menus SET Binary Entry Menu Selection SDH Payload Mapping Making Selections using Pictorial and Graphic DisplaysATM Physical Layer Selections Jitter Mask set to Off Jitter Mask SelectionJitter Mask set to Swept Jitter Mask set to Spot Using with a MonitorUsing the Other Front Panel Keys Using the Other Front Panel Keys Displaying Status History Monitoring StatusPDH / DSn Alarm Indicators General Alarm IndicatorsATM Alarm Indicators Jitter Alarm IndicatorsSonet Alarm Indicators Option SDH Alarm IndicatorsVT path RDI has been detected Index IndicatorsPointer Adjust Indicator, 29 Pop-up menus Asia Pacific Hewlett-Packard Sales and Service OfficesAustralia/New Zealand CanadaHewlett-Packard Sales and Service Offices cont’d Latin AmericaUnited States About This Edition This Book
Related manuals
Manual 12 pages 57.02 Kb

37717C specifications

The HP 37717C is a high-performance modular test and measurement instrument designed to provide unparalleled accuracy and versatility for a wide range of applications. Targeted primarily at engineers and researchers in communications and signal processing, this instrument offers essential features and advanced technologies that cater to the evolving demands of modern testing environments.

One of the main features of the HP 37717C is its exceptional frequency coverage. With the ability to operate from a few hertz up to a staggering 2.65 GHz, it can effectively handle various signals, from low-frequency audio to high-frequency RF applications. This broad range is crucial for telecommunications testing, as it allows engineers to assess components such as amplifiers, mixers, and modulators accurately.

The HP 37717C incorporates state-of-the-art digital signal processing (DSP) technology, allowing for real-time analysis and measurements. This technology enhances the accuracy and speed of data acquisition, making it efficient for both time-sensitive applications and complex signal analyses. Furthermore, it is equipped with advanced error detection capabilities that help identify and correct signal distortions, ensuring the integrity of the data being processed.

Another standout characteristic of the HP 37717C is its modular design. This instrument can be easily integrated into larger test systems, facilitating seamless upgrades and expansions. Users can customize their setups based on specific testing needs, whether that involves adding new measurement capabilities or incorporating additional channels for multi-channel testing.

The instrument also features a user-friendly interface, complete with an intuitive graphical display that enables quick navigation through its wide array of functions and settings. This ease of use enhances productivity and reduces the learning curve for new users, allowing them to focus on their testing objectives rather than struggling with complex controls.

Moreover, the HP 37717C supports various communication protocols and standards, making it adaptable for different industries ranging from aerospace and defense to consumer electronics. Its versatile capabilities ensure that it remains relevant as technology progresses and new standards emerge.

In summary, the HP 37717C stands out in the realm of test and measurement instruments due to its strategic combination of extensive frequency range, advanced DSP technology, modular design, and user-friendly interface. These features make it an indispensable tool for engineers and researchers striving for precision in their testing endeavors.