HP File System Extender (FSE) manual Achieving the FSE Database Consistency fsebak -suspend

Page 24

2.3 NAME

24

Partition Manager processes (fse–pm) for all configured FSE partitions must be running. This can be checked with the fsesystem command.

After successful command execution, fsebak notifies the FSE administrator with a suitable message, which is printed to the standard output stream (stdout). If there was an error during command execution, an appropriate error message is printed to the standard error stream (stderr).

ACHIEVING THE FSE DATABASE CONSISTENCY fsebak – –suspend

follows for each running Partition Manager the following procedure:

block the incoming job requests in Partition Manager;

make the corresponding HSMDB and FSC incorporate all changes from their transaction logs into the main database files;

write temporary files hsm.ref and fsc.ref with references to HSMDBs and

FSCs for use with the –continueoption;

• report action success or failure.

Note:

Contents of hsm.ref and fsc.ref files should not be directly altered in any way.

If all these steps are successfully completed, duplicate copies of HSMDBs and FSCs can be made.

RESUMING NORMAL FSE SYSTEM OPERATION fsebak – –continue

StatusCode follows for each running Partition Manager the following procedure:

read references to HSMDBs and FSCs from files hsm.ref and fsc.ref ) and delete these two files;

start accepting incoming job requests in Partition Manager and resume nor- mal operation.

If the value 0 (zero) is used in place of the StatusCode argument, all old transaction log files of HSMDBs and FSCs are removed, as the assumption is they will not be needed any more. If any other value is used as the StatusCode, these transaction logs are preserved for a potential future use.

HP StorageWorks File System Extender Software CLI reference

Image 24
Contents File System Extender Software FSE command index ContentsVolumeName SynopsisDescription Name Process FSE Daemon Service Partition Manager S Back End Agent S Library Agent SFSE administrator can set up two POST-START and PRE-STOP ScriptsFse -mount command. If Command fse -dismount-ntfsOptions StartName Stop RestartVolumeName Name StatusMountPoint Dismount-ntfsLimit-access Full-accessList-volumes Examples \fs020050da45607 \ Fse -list-volumes -detail Files See Also Fsesystem8, fsepartition8, fserestore8, fseintro7Copyright BackupFileName -nomedia BackupFileName -m- -medium BarcodeName Name Name Name Hsmlvvar = hsmvg/var Hsmlvpart = hsmvg/partSnapshotpct = BackupFileName Name Nomedia MediumBarcode InitFsebackup -fbackupimagefile.tar.bz2 Fsebackup -file .- -nomediaFsebackup -f /mnt/backup/backupimagefile.tar.bz2 -nomedia Fsebackup -medium bkpmed02See Also Fserestore8, fserecover8, fseintro7 Name FilesFsebak Fsebak -suspend Fsebak -continueFsebak -h Fsebak VersionAchieving the FSE Database Consistency fsebak -suspend Resuming Normal FSE System Operation fsebak -continueSuspend ContinueStatusCode See Also Fse8, fsesystem8, fseintro7 Fsecheck Fsecheck -i -fsc-hsmfs PartitionName Fsecheck -mBarcode Barcode Match-mediaFsc-hsmfs LOG ConsistencyPartitionName Name Fsc-media Alog ConsistencyAutocorrect Name Volume Fsecheck -fsc-hsmfs dailyreportsFsecheck -fsc-media archivepart32 Fsecheck -fsc-media -autocorrectSee Also fserecover8, fseintro7 Fsecheck -fsc-media -barcode 000101 000102 dm002Add ConfigFileName NameAdd ConfigFileNameRemove NameName Show RevisionNumberHistory ListDisable EnableName Detail Libdrive01 DriveAB -FSee Also Fse8, fselibrary8, fsemedium8, fsepool8, fseintro7 FileName... -D PartitionName FileID... -datePath FileNameName FileName SizeList option Detail Name History FileIDIdPartitionName FileID... argument combination InputFile Utf8Name Date MigidInto MigrateRelease Trigger-deletionFsefile -list updateMe.gz -detail No-monitorToring Fsefile -list file1 file2 file3 -sizeFsefile -recall -if RecallFileList.txt -utf8 Fsefile -recall -ifFsefile -recall FSEPartition010 30600 -date 2002/12/10Fsefile -Sweek50 week51 /mnt/fsevg/weekly-archives/week52 Fsefile -trigger-migrationPartition03 Fsefile -trigger-deletion partitiondeleteme -F -no-monitorJobID Priority JobID NumberDecr Number HP StorageWorks File System Extender Software CLI reference Migration List migration jobs Recall List recall jobs Admin Recovery List recovery jobsJOB List Information Name Maint JobIDAbort PriorityName Incr DecrFsejob -list -migration -recall Fsejob -l -A partitionnew -DFsejob -p20021206000614 See Also Fsesystem8, fsepartition8, fsefile 8, fseintro7Name RevisionNumber -H- -history Name ConfigFileNameName of the FSE library configuration file to use Name of the FSE library to manage configuration for Name List UnloadNrShow-inventory LibraryName RescanName Enable Fselibrary -r libsupplemental -forceFselibrary -show systemlib Fselibrary -showmainlibrary storagelibrarycfg.fseFselibrary -update-inventory libemail -rescan Disable the FSE library named AITlibrary skip confirmationFselibrary -disable AITlibrary -force Enable the currently disabled FSE library named LTOlibraryHP StorageWorks File System Extender Software CLI reference Barcode Description Options Name Pool PoolNameName Format Command fsemedium -list -volume Name If -remove ,- -mark-unreliable ,- -mark-unusable Mark-unreliableClose-volume Mark-unusableMark-good Copy-contents Recreate-friDuplicate ReorgFsemedium -add backuptape05 Fsemedium -abackuptape10 -poolpoolbkpFsemedium -rbackuptape13 Fsemedium -r backuptape78 -FFsemedium -init tape4a -volume 1 -no-monitor Fsemedium -close-volume ait60Fsemedium -format work35 -F -init Fsemedium -i workoffline45 -forceFsemedium -reorg tape56 -volume 1 2 5 Fsemedium -copy-contents damagedmedFsemedium -reorg tape55 -no-monitor Fsepartition -h Fsepartition VersionName Partition Status Information Partition status information that isOptions Add Status HSM FS Partition PART. Manager NormalName of the FSE partition configuration file to use Or -disable option Show Detail Reorg-scan ExpirationDateNumberOfGenerations Reorg-statSlackThreshold% Fsepartition -addclient02part05.fseFsepartition -r client03part03 -force Fsepartition -show client01part02Fsepartition -disable client03astropics -F Fsepartition -status mailpartition01Fsepartition -reorg-scanverytemporarypart 2003/09/20 100000 Fsepartition -reorg-stat client03astropics FilesOpt/fse/newconfig/fse-partition-NEVER-RELEASE.cfg Copyright C 2002-2005 Grau Data Storage Fsepool Fsepool -aFsepool -r Fsepool -sName Name Options Add Name History Name Detail Fsepool -remove systembackuppool -F Fsepool -show projarchivepool -HFsepool -l -D InstallPath% \newconfig \fse-pool-AIT-MANY-SMALL-FILES.cfg Opt/fse/newconfig/fse-pool-AIT-MANY-SMALL-FILES.cfgHP StorageWorks File System Extender Software CLI reference Fserecover Var/opt/fse/tmp/.PartitionNamehsmfsrecover Fsejob -a JobIDLimitations Fserecover -fsc fsefs01 Fserecover -hsmfs fsefs01Options Fsc HsmfsName 100 See Also Fsecheck8, fsepartition8, fseintro7 file BackupFileName Restore Concepts Fserestore copies the backup image from the specName 102 Name 103 Options fileName 104 Device OffsetCount Fserestore file Name 105 Retrieve-toFserestore -d id0200 -offset Fserestore -d /dev/sg3-o 3 -count 2 -retrieve-to /tmpName 106 Dev/sg5See Also Fse8, fsebackup8, fserecover8, fseintro7 Name 107Name 108 FsesystemStatus Partition PART. Manager HSM FS Error Name 109Name 110 Options ShowEnable-dbg Name 111Status Information SysDbgLevelName 112 SysDbgFileSysDbgFlags Disable-dbg Name 113SysDbgHSMFS Name 114 Help Fsesystem -show fseconfig.fseFsesystem -mfseconfignew.fse Name 115 See Also Fse8, fsejob8, fsepartition8, fseintro7
Related manuals
Manual 99 pages 2.23 Kb Manual 328 pages 27.8 Kb Manual 92 pages 24.26 Kb Manual 26 pages 22.37 Kb

File System Extender (FSE) specifications

HP File System Extender (FSE) is a sophisticated solution designed to optimize data storage management for enterprises that deal with large volumes of unstructured data. This technology addresses the challenges of data growth and the need for effective data retention strategies, enabling organizations to store and manage their information more efficiently.

One of the main features of HP FSE is its ability to intelligently migrate data between primary and secondary storage. By utilizing policies that determine when to move infrequently accessed files to lower-cost storage environments, FSE helps reduce the strain on primary storage systems and saves on costs associated with high-performance storage solutions. This tiered approach to data management ensures that organizations can access the data they need quickly while still maintaining an efficient overall storage architecture.

Another notable characteristic of HP FSE is its seamless integration with existing storage infrastructures. The solution works with a variety of storage systems, allowing organizations to utilize their current investments without the need for significant changes to their infrastructure. This interoperability is powered by advanced technologies that facilitate data migration and retrieval, ensuring a smooth transition for organizations looking to optimize their storage strategies.

Additionally, HP FSE is equipped with robust reporting and analytics capabilities. This functionality provides organizations with insights into their storage usage, helping them understand data patterns and optimize their storage environments accordingly. By having visibility into which files are accessed most frequently and which are rarely used, organizations can make informed decisions on data retention policies and storage management.

Security is paramount in data management, and HP FSE addresses this concern by implementing advanced data protection features. This includes data encryption, secure access controls, and compliance with industry regulations, ensuring that sensitive information is safeguarded throughout its lifecycle.

Overall, HP File System Extender is a comprehensive data storage solution that combines intelligent data management, seamless integration, insightful analytics, and robust security features. By leveraging these capabilities, organizations can efficiently manage their unstructured data, lower costs, and enhance operational efficiency, making it an invaluable tool in today’s data-driven landscape.