Soleus Air PH5-13R-35D manual Operating the Unit Using the Control Panel, Air Conditioner Mode

Page 10

CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS

CONTROL PANEL BUTTONS (Refer to the images on page 9)

1)Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off.

2)Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto mode, Air Conditioner, Dehumidifier, Fan only, and Heater mode.

3)Fan Speed Control - Press the FAN SPEED Button to cycle through the different fan speeds: High, Medium, and low. The fan speed can be visually distinguished by the speed of the digital air segments progressing out from the windmill fan image on the led control display. There is an additional auto speed setting that is enabled in only heating and cooling modes. This speed is next setting after low when press- ing the speed control button. The speeds will cycle through in this order: High, Medium, Low, Auto. Each change in speed will be associated with a “beep” sound from the unit.

4)Temperature - Select the desired temperature by pressing either or key when using the unit in cooling or heating mode. The temperature indicator flashes to display the desired temperature setting. After the temperature is set, the unit will display this temperature setting until it is changed by the user. The led control display shows temperature in Celsius or Fahrenheit. Press the and simultaneously to change from C° to F°.

5)TIMER*- To program the Auto-on timer, first press the TIMER button when the unit is off. Once the TIMER button is pressed the hours will blink on the display. Press the or buttons to change the number to the desired hours for the unit to automatically turn on. To program the unit to turn off automati- cally press the TIMER button when the unit is on to set the off timer. The display will flash the hours to turn off the unit. Press the or buttons to change the hours to the desired time for the unit to automati- cally turn off. The timer is set when the auto-off time stops flashing.

*NOTE: For a more sophisticated clock timer, use the included LCD remote control.

OPERATING THE UNIT USING THE CONTROL PANEL

Air Conditioner Mode

1)Install the exhaust hose and window kit properly (see pages 7 & 8 ).

2)Plug the Power Cord into an electrical outlet.

3)Turn on the unit by pressing the POWER button on the control panel.

4)Press the Mode button until the “ ” icon appears on the led control display

5)Press the or buttons until the desired room temperature appears on the control panel display. The temperature ranges from 61°F - 88 °F (16 °C - 31 °C).

6)Select the desired fan speed by pressing the FAN button.

NOTE: During hot days, the unit will cool the room most efficiently by setting the temperature at the lowest setting and the fan speed on high. Reducing the length of the exhaust duct, insulating the exhaust hose and window kit, and keeping direct sunlight to a minimum will also improve the cooling efficiency.

10

Image 10
Contents Item Number LX-130 Model Number PH5-13R-35D Important Instructions Package Contents SpecificationsLcdi Power Cord and Plug Reset TestProduct Diagram Assembly & Installation Parts & AssemblyParts Venting KIT Installation Window KIT Assembly Control PANEL, DISPLAY, & Operating Instructions Control Panel & LED Control DisplayOperating the Unit Using the Control Panel Air Conditioner ModeHeating Mode Compressor Indicator Operating the Unit Using the Remote Control Remote Control Operating Instructions Maintenance DisclaimerWarranty One Year Limited Warranty