Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow. Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re- circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure, and the same operating guidelines listed above will still apply.
Temperature Range | Operating: 50° to 95° F (10° to 35° C)* |
| |
Relative Humidity | Operating: 10% to 90% |
| |
Maximum Altitude | Operating: 10,000 ft (3048 m) |
(unpressurized) |
*Operating temperature is
Power Supply |
| Small Form Factor | Convertible Minitower |
Power Supply | 135W external power supply, 85% | 240W power supply, active PFC | 365W power supply, active PFC |
| efficient, active PFC |
|
|
Operating Voltage Range | 90 – 264 VAC | 90 – 264 VAC | 90 – 264 VAC |
Rated Voltage Range | 100 – 240 VAC | 100 – 240 VAC | 100 – 240 VAC |
Rated Line Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Operating Line Frequency | 47 – 63 Hz | 47 – 63 Hz | 47 – 63 Hz |
Range |
|
|
|
Rated Input Current | N/A | 4A | 6A |
Rated Input Current with | 1.5A | 3.5A | 5A |
Energy Efficient* Power |
|
|
|
Supply |
|
|
|
Current Leakage | < 275 µA | < 275 µA | < 450 µA |
(NFPA 99) |
|
|
|
System Heat Dissipation | N/A | Typical 198 btu/hr | Typical 222 btu/hr |
|
| (50 | (56 |
|
| Maximum 1260 btu/hr | Maximum 1916 btu/hr |
|
| (318 | (483 |
System Heat Dissipation | Typical 133 btu/hr | Typical 150 btu/hr | Typical 171 btu/hr |
with Energy Efficient* Power | (33.5 | (38 | (43 |
Supply | Maximum 549 btu/hr | Maximum 1024 btu/hr | Maximum 1557 btu/hr |
| (132 | (258 | (392 |
Power Supply Fan | N/A | 80mm variable speed | 92mm variable speed |