| Issue 6 | Software RAID 5 not supported | |
| 
 | 
 | 
 | 
| 
 | Description | HP and Novell have discovered issues where failed drives in software RAID 5 | 
| 
 | 
 | environments may not properly rebuild and data corruption may occur. | 
| 
 | 
 | 
 | 
| 
 | Workaround | Use software RAID 0 or 1, or use hardware RAID 5 as an alternative. | 
| 
 | 
 | 
 | 
| 
 | Solution | Novell is communicating to customers that software RAID 5 will not be supported until the | 
| 
 | 
 | release of SP1 or later. Software RAID 0 and 1 are fully supported with the base media. | 
| 
 | 
 | |
| Issue 7 | Improper iSCSI configuration can lead to data corruption | |
| 
 | 
 | 
 | 
| 
 | Description | Improper configuration of iSCSI Target and Initiator access can cause data corruption. | 
| 
 | 
 | 
 | 
| 
 | Workaround | Novell has detailed documentation on how to properly configure iSCSI Targets and | 
| 
 | 
 | Initiators. The documentation can be viewed at www.novell.com/documentation. | 
| 
 | 
 | 
 | 
| 
 | Solution | Follow the Novell documentation. Novell is also planning to add additional measures in | 
| 
 | 
 | Support Pack 1 (SP1) to help prevent this problem. | 
| 
 | 
 | |
| Issue 8 | Insight Manager Web Agent may hang the server | |
| 
 | 
 | 
 | 
| 
 | Description | Attempting to access the HP Insight Manager Web Agent from the server browser may | 
| 
 | 
 | cause the server to hang. This problem only appears in the server browser and does not | 
| 
 | 
 | occur when accessing the Web Agent from a  | 
| 
 | 
 | 
 | 
| 
 | Workaround | Do not attempt to access the Web Agent from the server browser. Use a workstation | 
| 
 | 
 | browser instead. | 
| 
 | 
 | 
 | 
| 
 | Solution | This is a known issue with HP’s implementation of the Web Agent module and will not be | 
| 
 | 
 | fixed. | 
| 
 | 
 | |
| Issue 9 | Unloading ACPIMGR.NLM will cause the server to abend | |
| 
 | 
 | 
 | 
| 
 | Description | Unloading the support module ACPIMGR.NLM will cause the server to abend. | 
| 
 | 
 | 
 | 
| 
 | Workaround | Do not unload ACPIMGR.NLM. | 
| 
 | 
 | 
 | 
| 
 | Solution | Novell is planning to fix this issue in SP1. | 
| 
 | 
 | |
| Issue 10 | Unpredictable behavior with the ATI Rage XL 8 MB video driver | |
| 
 | 
 | 
 | 
| 
 | Description | The ATI Rage XL 8 MB video driver may cause unpredictable behavior in the server GUI. | 
| 
 | 
 | Selection of this driver on supported servers may cause problems varying from loss of | 
| 
 | 
 | keyboard and/or mouse functionality to server hangs and abends. This problem is | 
| 
 | 
 | intermittent. | 
| 
 | 
 | 
 | 
| 
 | Workaround | See Solution. | 
| 
 | 
 | 
 | 
| 
 | Solution | Use the default video driver that is automatically selected during installation. Novell has | 
| 
 | 
 | decided to archive this driver, so it will no longer be maintained and it will be removed | 
| 
 | 
 | from the Novell Overlay CDs for SP1 and later. This driver will remain on the base | 
| 
 | 
 | media; however, it should not be used. | 
| 
 | 
 | |
| Issue 11 | Server may hang with large NSS  | |
| 
 | 
 | 
 | 
| 
 | Description | The NSS file system can hang if the SET parameter "NSS Read Ahead" is set to a value | 
| 
 | 
 | greater than 128. The server will appear to be functioning, but no disk activity can be | 
| 
 | 
 | completed due to constrained resources as a result of the parameter setting. | 
| 
 | 
 | 
 | 
| 
 | Workaround | Set the "NSS Read Ahead" parameter to a value of 128 or less. | 
| 
 | 
 | 
 | 
| 
 | Solution | Novell is planning changes for SP1 that will properly comprehend settings greater than | 
| 
 | 
 | 128. | 
| 
 | 
 | 
 | 
| 
 | 
 | 17 |