Sterling STT 300 operating instructions Dehumidified Air Dryer For your safety, General

Page 12

Dehumidified Air Dryer

2.1. For your safety

General

The operating personnel of this equipment must be at least 16 years old.

Please read these operating instructions carefully before taking into operation for the first time. Contact us should questions arise. This avoids injury and damage to equipment!

These operating instructions must be kept available at all times at the place of operation of the equipment. Improper operation results in danger of accidents!

Please note that, for reasons of clarity, not all conceivable cases regarding operation or mainten- ance of the equipment can be covered in these operating instructions.

Please observe all safety instructions and warnings on the equipment. This avoids injury and da- mage to equipment!

All work on the equipment is to be carried out by persons whose qualifications are specified in the pertaining chapters of the operating instructions. Improper operation results in danger of acci- dents!

The proper working clothes are to be worn during any work on the equipment. This avoids injury!

The local regulations and requirements pertaining to this equipment must be observed.

Disconnect electrical components from the mains supply before work is carried out on these com- ponents Caution: Danger to life through electrical shock!

Compile detailed operating instructions based on these Operating instructions for the sequence of procedures to be carried out on this equipment. Improper operation results in danger of acci- dents!

Observe that the control system is still under voltage even when the main switch is switched off. Caution: Danger to life through electrical shock!

SM2-615

Safety instructions 2-2

Image 12
Contents Sterling Material Processing Parts and Service Department STT Sterling Material Processing Edition 05/02 Order confirmation numberSTT Table of Contents Transport, Assembly and Storage Spare parts list General Information Dehumidified Air DryerGeneral Information Dehumidified Air Dryer Dehumidified Air Dryer Explanations and information Legal basisFields of applications Safety instructions Safety instructionsDehumidified Air Dryer For your safety GeneralAssembly OperationMaintenance Dehumidified Air Dryer For the safety of the devices Start-up Start-upSTT Control system Key assignmentSTT Flow chart Indicator lamp messagesSTT Switching on the dryer Operation statusesPasswords STT Viewing the software-versionLogin LogoutEdit Timer on/off STT Basic parametersTurning the devices on/off Dryer on/offSTT STT Entering dryer values Regeneration Heater ActUsed air Act Dew point maxReturn air cooler Target Return air cooler ActSTT Entering hopper values Hopper entry X TargetHopper entry X Act Granules Target % = C Granules Act. CValve block moved in/moved out/error STT Observing processing statusSTT Setting date and time DateTime STT Viewing/changing language and contrast ContrastLanguage STT Changing parameters Select ParametersRun on time drying blower -- 300 sec ParametersSTT Setting the timer XX on 0000 OFF 0000 XX = day Mo-SuExample STT Starting continuous operation Select Main menuSTT Viewing system runtime Select System runtimeSystem runtime XX hSTT Switching the dryer off Error and error correction Error and error correctionLED Alarm View Number Total messagesWaiting messages DeleteOverflow Overflow warning On/OffMain Switch is Off Safety Temperature Limiter has been ActivatedSafety Switch Regeneration Blower Has Been Actuated Safety Switch Drying Blower Has Been ActuatedTemperature Measurement Regeneration Heater Defective Excess Temperature Regeneration HeaterInsufficient Temperature Regeneration Heater Safety Switch Regeneration Heater Has Been ActuatedTemperature Measurement Drying Heater Defective Excess Temperature Drying HeaterInsufficient Temperature Drying Heater Safety Switch Drying HeaterTemperature Measurement Granules Defective Hopper Excess Temperature Granules HopperValve Error Hopper Maintenance MaintenanceSTT STT Maintenance intervals STT Cleaning/renewing the air filters Return air filter Regeneration air filter Filter of the electrical cabinet STT Tensioning the V-belts Blower regeneration heater / Blower drying heater Servicing the accessories Disposing of the drying agentHigh-pressure blowers with frequency converter operation STT Changing the battery of the control system STT STT Resetting the control values Functional description Functional descriptionDew point dependent regeneration switch optional STT DryerSTT Drying hopper optional STT Return air cooler optional STT Hopper heaters optional Automatic motor flaps optionalConnection to a pneumatic conveying system optional Transport, Assembly and Storage Transport, Assembly and StorageDehumidified Air Dryer Transport and Packing With a fork lift truckWith a workshop crane Dehumidified Air Dryer Assembly StorageAssembly instructions Assembly instructionsConnection of the air coolers optional Dehumidified Air Dryer Electrical connection Technical Data Technical DataBasic Equipment Optional EquipmentDimension sheet Spare parts list Spare parts listPos. ID-number Description STT Switching Cabinet and Operating Unit AccessoriesReturn air coler optional Flaps optionalElectrical manual Electrical manualAccessories AccessoriesAccessories Entering values on the OP 7 Entering Values Entering Numerical Values Entering Alphanumeric Values Step Procedure Entering Symbolic Values Accessories Flap control with Fuzzy-Logic Flap control with Fuzzy-Logic Control unit flap

STT 300 specifications

The Sterling STT 300 is a state-of-the-art vehicle designed for optimal performance and efficiency, aimed primarily at transportation and logistics companies. With its rugged construction and advanced technologies, this vehicle stands out in a competitive market.

One of the key features of the STT 300 is its powerful engine, which provides robust horsepower while maintaining excellent fuel efficiency. The engine is paired with an advanced transmission system that ensures smooth acceleration and seamless gear shifts. This combination not only enhances the overall driving experience but also contributes to lower operating costs over time.

The chassis of the Sterling STT 300 is built from high-strength materials, offering superior durability and the ability to handle heavy loads without compromising stability. Its suspension system is designed for optimal comfort, allowing for a smooth ride even on uneven terrain. This makes it an ideal choice for companies that require a reliable vehicle for both urban and rural deliveries.

In terms of technology, the STT 300 is equipped with a modern infotainment system that includes features such as navigation, Bluetooth connectivity, and multimedia capabilities. This ensures that drivers can stay connected and informed while on the road, enhancing both safety and productivity.

Safety is a paramount concern in vehicle design, and the STT 300 does not disappoint. It comes with an array of safety features, including advanced braking systems, stability control, and multiple airbags. This comprehensive suite of safety technologies helps protect both the driver and cargo during transport.

The interior of the Sterling STT 300 is designed for practicality and comfort, featuring ergonomic seating and a user-friendly dashboard layout. Ample storage space is provided for tools and other essentials, making it suitable for various logistical operations.

Furthermore, the vehicle is known for its environmental considerations, being compliant with stringent emissions standards. This not only benefits the planet but also enhances the brand's reputation among eco-conscious consumers.

In summary, the Sterling STT 300 combines power, efficiency, safety, and comfort, making it an excellent choice for transportation and logistics applications. Its robust build, advanced technologies, and commitment to sustainability position it as a leading option for businesses seeking reliable vehicle solutions.