All installations and services must be performed by qualified service personnel.

3.Flue Pipe Connection & Chimney for MDA1/MHA1: Visually check flue pipe and chimney for tightness, blockage and corrosion. If fittings are loose or if blockage or corrosion is suspected to be a problem, contact a qualified heating contractor. Make sure horizontal runs of the flue have an upward slope away from furnace of 1/4" per foot minimum and are physically sound without holes, cracks or signs of corrosion. There should be no sign of moisture or vent gas leakage at any vent connection.

ADDITIONAL REQUIREMENTS OF FURNACES VENTED THROUGH THE SIDE OF THE HOUSE WITH NO CHIMNEY.

a.Such horizontally vented furnaces should also be inspected to make sure that all vent joints are sealed and that the outside vent terminal is clear and free of obstruction by ice, snow or debris. Any obstruction of the terminal should be carefully removed without damaging the vent terminal. If ice has formed on the terminal itself, it should be removed using a blow dryer.

b.The sidewall venting kit (SWGII Power Venter) manufacturer’s instructions to be supplied by Field Controls. Use information must be supplied by the installer then read and understood by the user.

4.If a CDB1/CHB1 or CDX1/CHX1 furnace is equipped with a Thermo Products, LLC. condensate neutralizer kit, (See Figure 5) it should be inspected at the start of every heating season. Remove the 2” PVC cap from the neutralizer kit and replace dissolved filter material

with #9 limestone. Keep instructions for neutralizer kit in plastic pouch on the inside of the furnace blower door.

Figure 5.

5.Return Air Duct Connection: Check to see if it is (1) physically sound; (2) sealed to the furnace casing; and (3) terminates outside the space containing the furnace.

6.Make sure the furnace is sealed to the base (if applicable) without sagging, cracks or gaps. Make sure there are no signs of deterioration of the furnace or base.

7.Examine the entire furnace, including removing the vestibule door and inspect the control compartment and the furnace for signs of damaged or unusually worn wiring, condensation, sooting or other damage or deterioration.

8.Restore power to the furnace. Follow the operating instructions to light furnace.

15

Image 17
Contents GAS Furnace Index Section Beginning Safety Information Page Page Page II. General Instructions Page Page Page Page Operating Instructions to Start the Furnace Annual Inspection Shutdown Procedure To Turn OFF GAS to FurnaceCounterflow Furnace CDX1/CDB1/MDA1 Filter Maintenance ProcedureUpflow Furnace CHX1/CHB1/MHA1 Filter Replacement Visual Inspection Procedure

MDA1-100, CDB1-125, CHX1-75, CHB1-125, CDB1-50 specifications

Thermo Products is a recognized name in the heating and cooling industry, offering a range of solutions designed to meet various environmental control needs. Among their impressive lineup are the MDA1-100, CHB1-50, CHB1-75, CHX1-100, and CHX1-75 models. Each model boasts unique features and technologies that cater to both residential and commercial applications.

The MDA1-100 is an advanced air conditioning unit designed for maximum efficiency. It employs cutting-edge inverter technology, which adjusts the compressor speed to suit the cooling requirements dynamically. This not only results in lower energy consumption but also ensures quieter operation and improved temperature consistency. With a cooling capacity of 10,000 BTU, it is ideal for medium-sized spaces.

Moving on to the CHB1 series, both the CHB1-50 and CHB1-75 are heat pump units that offer both heating and cooling functionalities. The CHB1-50 features a heating capacity of 5,000 BTU, optimal for smaller applications, while the CHB1-75 can provide up to 7,500 BTU, making it suitable for slightly larger areas. These models utilize a unique refrigeration cycle that maximizes heat recovery, enabling efficient energy use during colder months while providing reliable cooling in warm weather.

Then we have the CHX series, which includes the CHX1-100 and CHX1-75. These high-performance units are designed to handle harsher climates, equipped with advanced defrost cycles to ensure operational reliability. The CHX1-100 has a robust cooling capacity of 10,000 BTU, catering to larger locations, while the CHX1-75 is adept for medium-sized areas with its 7,500 BTU capacity. Both models excel in energy efficiency, utilizing variable speed compressors for optimal performance.

A standout characteristic across these models is their straightforward installation and user-friendly interfaces. Many units are equipped with smart technologies, allowing users to monitor and control their systems remotely via smartphone applications. Additionally, the units are built with durable materials designed to withstand the rigors of different environments, ensuring longevity and reduced maintenance costs.

In conclusion, Thermo Products' MDA1-100, CHB1-50, CHB1-75, CHX1-100, and CHX1-75 collectively embody a commitment to innovation in climate control. They offer efficiency, adaptability, and advanced technology that make them excellent choices for any heating and cooling needs. Whether for residential or commercial application, these models provide reliable performance, ensuring comfort throughout the year.