SPX Cooling Technologies manual Recold / JT Series CoolingTower / Construction

Page 2

Recold / JT Series CoolingTower / Construction

2

Recold, the pioneer of Dri-Fan forced draft evaporative coolers, now applies this principal to the cooling of process water. With the fan in the supply air stream, away from the high humidity air leaving the tower, the fan shaft and bearing are assured longer life.

SYSTEM

The process water enters the spray tree at the top of the unit, is sprayed down onto the heat exchanger surface or “fill”, giving up heat to the counterflowing air before returning to the system from the sump pan. Moist air does not enter the fan assembly, resulting in longer life and fewer service problems.

HYDROSPRAY NOZZLES

Hydrospray nozzles are made of non-ferrous material, sized and spaced for optimum wetting of fill. The even distribution of spray across the fill material is extremely important in evaporative equipment.

ACCESSIBILITY

Recold cooling towers are designed for maximum accessibility for inspection and cleaning. Recold patented access doors on both sides of the unit provide ample access to the spray nozzles, fill, eliminators, bleeds and sump pan for service and maintenance. Recold access doors provide a complete air and water tight seal without gaskets or fasteners, and are “quick opening.”

CONSTRUCTION

Recold cooling towers are constructed of 300 series stainless steel (basin, fill supports and access doors) and heavy gauge hot dipped G-235 galvanized steel per ASTM A-525.

BLOWERS

A single, slow-speed forward curve blower is used for optimum efficiency and minimum noise. Each blower is balanced to eliminate unit vibration on Recold’s high precision electronic balancing equipment. Large blowers are made from galvanized steel and subject to careful quality control throughout. Fan shafts are coated to prevent corrosion. The blower drives are selected at 150% of rated brake horsepower.

Bearings are self-aligning, ball-bearing type, with external lubricating fittings and selected for 2000,000 hour average bearing life. Rugged, OSHA approved, belt guard and screen are provided for protection. Motor is mounted on an adjustable base.

INTEGRATED ASSEMBLY

Recold cooling towers are completely assembled at the factory and shipped as a unit.

FILL

High efficiency is accomplished by using a PVC fill design that provides the maximum amount of wetted surface within allowable airside pressure drop. Fill is conveniently sized for easy removal. The cooling tower fill shall be high efficiency, self-extinguishing PVC, a minimum of 40 mils thick. It shall have a flame spread rating of 25 per ASTM standard E-84 and be impervious to rot, decay, fungus or biological attack.

DRIFT ELIMINATORS

Eliminators are constructed of PVC assembled in removable, easy to handle sections. A three-pass design allows three changes in air flow resulting in decreased drift rates. The use of durable PVC eliminates the corrosion problems associated with galvanized eliminators.

TESTING

All Recold cooling towers are tested under the close supervision of the Quality Control Department before being released for shipment. Fans are run and spray systems operated to assure quiet, balanced operation without leaks, water carryover or vibration. Nozzles are checked for proper distribution.

Use this data for preliminary layouts only. Obtain current drawing from your Marley/Recold sales representative.

The UPDATE web-based selection software—available at spxcooling.com—provides JT Series model recommendations based on customer's specific design requirements.

Image 2
Contents Recold JT Series CoolingTower Recold / JT Series CoolingTower / Construction Schematic Recold / JC Series CoolingTowerRecold / JT Series CoolingTower / Accessories

JT Series specifications

SPX Cooling Technologies JT Series represents a significant advancement in cooling solutions, specially designed to meet the demanding requirements of various industrial applications. Known for their efficiency, reliability, and innovative design, these cooling towers are tailored to provide optimal performance while minimizing operational costs.

One of the main features of the JT Series is its exceptional thermal performance. The tower is engineered to maximize heat exchange capabilities, ensuring effective cooling even in high-demand scenarios. This is achieved through an advanced fill media design that enhances water film distribution, allowing for improved evaporative performance and maximizing the cooling effect. Additionally, the series offers customizable configurations, enabling users to select the most suitable size and capacity based on specific application needs.

Energy efficiency is paramount in the JT Series, and SPX Cooling Technologies has integrated several technologies to achieve this goal. The use of variable frequency drives (VFDs) on fan motors allows for precise control over airflow, making it easier to adjust cooling output according to fluctuating system demands. This feature not only reduces energy consumption but also extends the life of the equipment by minimizing wear and tear.

Durability is another characteristic that sets the JT Series apart. Constructed from robust materials, the cooling towers are designed to withstand harsh environmental conditions, ensuring longevity and reducing maintenance requirements. The corrosion-resistant coatings used in the design provide additional protection, making the towers suitable for various industrial environments, including chemical processing and power generation.

The JT Series also excels in ease of maintenance. The design incorporates accessible components, allowing for straightforward inspections and repairs. The removable panels facilitate quick access to the interior for cleaning and servicing, minimizing downtime and ensuring the system operates at peak efficiency.

Furthermore, SPX Cooling Technologies is committed to sustainability, and the JT Series reflects this dedication. The towers are designed to minimize water consumption and reduce environmental impact, aligning with contemporary sustainability practices and regulations in various sectors.

In summary, the SPX Cooling Technologies JT Series combines exceptional thermal performance, energy efficiency, durability, and ease of maintenance to provide a reliable cooling solution for industrial applications. Its innovative design and commitment to sustainability make it a leading choice for industries looking to optimize their cooling systems while keeping operational costs low. With its advanced features and technologies, the JT Series stands out as a benchmark in cooling tower solutions.