SPX Cooling Technologies Marley Aquatower manual Supporting Steel Plan

Page 5

/ Support /

25mm

H

CL

ANCHORBOLT

W G

ANCHORBOLT

CL

H

L

F

CANCHOR L BOLT

16mm DIAMETER HOLES

TOWER

COLLECTION BASIN

AIR INLET FACE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANCHOR

 

 

 

25mm 25mm

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

C

ANCHOR

BOLT

L

 

 

 

 

 

 

 

H

L

BOLT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANCHOR BOLT

 

 

TOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLLECTION BASIN

 

 

 

 

A

W G

 

 

16mm DIAMETER HOLES

 

 

 

 

 

 

 

ANCHOR BOLT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CL

 

 

AIR INLET FACE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

25mm

ANCHOR C BOLT L

B

 

SUPPORTING STEEL PLAN

 

 

 

SUPPORTING STEEL PLAN

 

 

 

 

OPTION ONE

 

 

 

 

 

 

 

OPTION TWO

 

 

 

TOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLLECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLLECTION

 

 

 

 

51

 

 

 

 

 

MIN. BEARING WIDTH

 

BASIN

 

 

 

 

 

 

 

 

 

25mm

 

 

 

 

 

BASIN

 

 

 

 

 

 

 

 

 

 

 

AT EACH ANCHOR BOLT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUPPORT

 

 

 

 

 

 

 

 

GAUGE

 

 

 

 

 

SUPPORT

 

 

 

 

 

 

 

 

 

 

GAUGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(BY OTHERS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(BY OTHERS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECTION A

 

 

 

 

 

 

 

 

VIEW B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tower

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

 

 

 

Maximum

 

 

 

 

 

Maximun

Wind Load kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping Weight

 

 

 

 

Operating Load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating

 

 

 

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kg

 

 

 

 

 

at Anchor

Max. Vertical

Max. Horizontal

 

L

 

 

 

 

 

 

W

 

F

 

G

H

 

kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kg

 

 

Reaction at

Reaction at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anchor

Anchor

490A-490B

 

902

 

1019

 

 

851

 

915

52

198

 

343

 

84

 

 

 

 

82

52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

492A-492B

 

1206

 

1260

 

 

1156

 

1067

97

337

 

633

 

158

 

 

 

161

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

493A-493B

 

1816

 

1206

 

 

1765

 

1067

97

445

 

905

 

226

 

 

 

238

129

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

494A-49B

 

1816

 

1680

 

 

1765

 

1524

78

634

 

1337

 

334

 

 

 

252

161

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

495A-495B

 

2426

 

1680

 

 

2375

 

1524

78

797

 

1294

 

437

 

 

 

338

213

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

496A-496B

 

3035

 

 

 

1680

 

 

2985

 

1524

78

951

 

2155

 

 

 

539

 

 

 

497

290

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models with Vertical Discharge Hood Option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

494A-494C

 

1816

 

1680

 

 

1765

 

1524

78

816

 

1519

 

380

 

 

 

316

234

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

495A-495B

 

2426

 

1680

 

 

2375

 

1524

78

968

 

1920

 

480

 

 

 

338

234

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

496A-496B

 

3035

 

 

 

1680

 

 

2985

 

1524

78

1178

 

2382

 

 

 

596

 

 

 

497

290

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Use this bulletin for preliminary layouts only. Obtain current draw- ings from your Marley sales representative or your local distribu- tor.

2.Purchaser to provide tower supports complete with holes and bolts for anchorage. All supports must be framed flush and level at top. Maximum deflection to be 1/360th of span, not to exceed 13mm.

3.Maximum weight occurs with basin full to overflow level at shutdown. Actual operating weight varies with flowrate and piping scheme.

4.Wind loads are based on 1.4 kPa and are additive to operating loads. Reactions due to wind loads exceed those resulting from seismic loads based on the 1997 UBC code, Zone 4 and an Impor- tance Factor of 1.00 per Section 1634—Towers Not on a Building.

Use this data for preliminary layouts only. Obtain current drawing from your Marley sales representative.

The Marley UPDATE web-based selection software —available at spxcooling.com provides Aquatower model recommendations based on customer's specific design requirements.

5

Image 5
Contents Marley Aquatower CoolingTower  Aquatower Advantage Marley Difference Dimensions SchematicSupporting Steel Plan SupportWater Distribution System Construction And ComponentsFill/Louvers/Drift Eliminators Cold Water Collection BasinMechanical Equipment SafetyHoisting and Handling Construction and FinishElectric Basin Heaters Freeze PreventionIndoor Tank Method Basin Heater SelectionField Assembly Field AssemblyComponent Sizes and Weights Drain-Down CapacityOption Description OptionsMotor Motors shall be kW, Totally Enclosed, specially SpecificationsWorcester WR3 8AB United Kingdom

Marley Aquatower specifications

SPX Cooling Technologies, a renowned leader in cooling tower solutions, has made significant strides in the industry with the introduction of the Marley Aquatower. The Marley Aquatower is engineered to provide efficient and reliable cooling for a variety of applications, including industrial processes and HVAC systems. This innovative cooling tower showcases state-of-the-art features and technologies that set it apart in the market.

One of the standout features of the Marley Aquatower is its unique modular design. This design allows for easy installation and scalability, enabling users to customize their cooling solutions according to their specific needs. Additionally, the modular setup aids in reducing the overall footprint of the cooling tower, making it an ideal choice for facilities with spatial constraints.

The Marley Aquatower utilizes advanced materials and construction techniques to enhance durability and performance. Built with high-quality corrosion-resistant materials, the unit is designed to withstand the harshest environmental conditions, ensuring long-term reliability and minimal maintenance requirements. This is particularly advantageous for operations that are looking to reduce downtime and maintenance costs.

In terms of technology, the Marley Aquatower incorporates several innovations aimed at improving energy efficiency. The unit features a highly efficient heat transfer design that optimizes thermal performance while minimizing water consumption. This ensures that the cooling process is not only effective but also environmentally friendly. The combination of efficient fans and a well-designed airflow system further enhances energy savings, making it a sustainable choice for modern cooling needs.

The Aquatower is equipped with advanced monitoring and control systems, allowing operators to track performance metrics and make necessary adjustments in real-time. This technology enhances operational efficiency and facilitates proactive maintenance strategies, reducing the risk of unexpected failures and enhancing overall system reliability.

Another characteristic that stands out is its quiet operation. By incorporating noise-reducing features, the Marley Aquatower can be installed in noise-sensitive areas without causing disruptions, making it suitable for urban environments and other locations where noise levels must be managed.

In conclusion, the SPX Cooling Technologies Marley Aquatower combines innovative design, advanced materials, and energy-efficient technologies to deliver a top-tier cooling solution. With its modular construction, durability, efficiency, and quiet operation, it has become a preferred choice for a wide range of industrial and HVAC applications, setting new standards in the cooling tower industry. The Marley Aquatower is an embodiment of SPX’s commitment to providing superior cooling solutions that meet the evolving needs of the marketplace.