Roberts Gorden TF-Series Protective Grille Installation, Silicone Cap Installation, 101 cm

Page 31

ROBERTS GOR DON® TF-SE RIE S SUB MI TT AL SHEE T

PROTECTIVE GRILLE INSTALLATION

Silicone Cap Installation

 

Silicone Cap

 

Grille

Description

Part Number

Grille Section

08050001

Finger

Grille End Cap

08050002

 

 

Silicone Cap

91915951-6P

Grille End Cap Installation

B

A

Grille

Grille End Cap

C

D

 

Bend up 90°

Pull outward

 

Grille Installation

Reflector

40 "

(101 cm)

Final Grille

Section

Grille

Grille

End Cap

© 2004 Roberts-GordonAPPLICATION S, ENGI NEERING AND DETAI LED GUID ANCE ON SYSTEMS DESIGN, INSTALLATI ON AND PRODUCT PERFORMANCE IS AVAI LABLE UPON REQUEST. ROBERTS GORDON® PRODUCTS ARE TO BE INSTALLED ONLY IN ACCORDANCE WI TH LOCAL LAWS, CODES AND REGULATIONS, AND ONLY BY A CONTRACTOR QUALI FIED I N THE I NSTALLATION AND SERVICE OF GAS-FIRED HEATING EQUI PMENT.

Image 31
Contents Twin Fire Unitary Infrared Heater Page 2004 Page Contents of TF-Series Burner Carton Standard Parts ListContents of Core and Extension Packages General Specifications One Side Reflector Inches Centimeters Standard Reflector Inches CentimetersTwo Side Reflectors Inches Centimeters Tube, Standard Reflector Inches Tilt Reflector Inches CentimetersTube, Full Inches Centimeters TF-200 102 181 Inches CentimetersLower Clearance Shield Inches UnapprovedInfrared Tubes Pipes VentingUnvented VentTF-SERIES Assembly Overview Reflector End Cap Tube Coupling Burner Tube TF-Series Linear Assembly OverviewCritical Hanger Placement Heater InstallationDescription Part Number TF-Series Linear Layout Overview TF-350 TF-380 TF-300Burner Installation BBurner Tube InstallationClosed Tube Clamp Package InstallationCoupling and Tube Assembly Open229 cm ± 25 cm 10 Typ. ± Cm Typ ± 25 cm Dimensions Incorrect Slide Bar PositionModel Burner Hanger Burner Tube Reflector Turbulator InstallationReflector Installation Turbulator Section Turbulator Tab AdapterOption B Reflector, U-Clip and Reflector Support InstallationOption a TF-Series U-Tube Assembly Overview Optional Heater AccessoriesTube, Standard Tube, Full Tube, Opposite TF-Series U-Tube Layout Overviews TF-300 60 18m Tube Length each side Reflector Joi29 Elbow Package ConfigurationElbow Installation Reflector Joint InstallationReflector Joint Detail Nt InstallationJoint 02712700 Bracket InstallationSide Reflector Installation Reflector Side ExtensionGrille Installation Lower Clearance Shield InstallationShield Support Strap Assembly TWO-FOOT Decorative Grille InstallationDistance a Extension Frame Shield InstallationReflector Side Extension Installation ShieldJoint Piece and Reinforcement ONE-FOOT Decorative Grille InstallationOne-Foot Decorative Grille Bracket Decorative GrilleEnd Piece End Piece and Reflector End CapElbow Reflector joint pieceFinal Grille Protective Grille InstallationSilicone Cap Installation 101 cmCombustible or Non-Combustible VentingHorizontal Ventilation 4 10 cm Pipe Vertical Ventilation 4 10 cm PipeTube Combustible or Non-Combustible CFlexible Boot Installation Single VentCommon Sidewall Venting Burner Cm Single Wall Pipe Vent TerminalRoof Flexible Boot Installation Common VentRolled Sleeve Installation For Common Vent Vertical Ventilation 6 15 cm PipeApproved Vent Cap Outside Combustion AIR SupplyVertical Outside Air Supply Horizontal Outside Air SuppllyFlex Gas Line 91412200 91412203 GAS PipingLine Voltage Thermostat Wiring WiringFront View Back View Low Voltage Thermostat and Relay WiringTF-Series Ladder Diagram TF-Series Internal WiringElectrical Connection to the Burner Wire Connector Conduit HoleBlower with DoorScreen and Gasket Internal Burner DiagramROBERTS-GORDON will not PAY for Warranty is Void ifLimitations on Authority Representatives Roberts GOR DON TF-SE RIE S SUB MI TT AL Shee T Roberts Gordon TF-SE RIE S SU BMI TT AL Shee T

TF-Series specifications

The Roberts Gordon TF-Series is a renowned line of infrared radiant heaters that exemplify efficiency and effectiveness in heating solutions. Designed for commercial and industrial applications, the TF-Series is engineered to provide comfortable heating in large spaces while minimizing energy consumption. One of its standout features is the use of high-intensity infrared heating technology, which directly warms people and objects in a space rather than just the air. This results in faster heat delivery and consistent warmth, contributing to enhanced comfort for occupants.

The TF-Series model incorporates several advanced technologies that set it apart in the market. Among its key characteristics is the advanced reflector system that maximizes heat distribution. These reflectors are engineered to direct infrared rays downwards, ensuring even heating across the floor space. The design also reduces heat loss, making the system highly efficient in energy usage. This makes the TF-Series ideal for environments where energy conservation is a priority, such as warehouses, factories, and outdoor settings.

Another notable feature is the flexibility of installation options. The TF-Series heaters can be mounted in various configurations, including overhead suspension or wall mounting, allowing for adaptability to the specific layout of any facility. This flexibility ensures that users can position the heaters optimally to achieve maximum coverage and efficiency.

Moreover, the TF-Series is built with durability in mind. The units are constructed from high-quality materials that can withstand the rigors of commercial environments. This resilience guarantees a long lifespan, which is vital for businesses looking to minimize maintenance costs over time.

In addition to functional features, the TF-Series excels in user-friendly operation. Many models come equipped with integrated controls that allow for easy temperature adjustments and programmability, facilitating a sophisticated approach to energy management. This capability not only enhances comfort but can also lead to significant reductions in operational costs.

Overall, the Roberts Gordon TF-Series embodies a blend of innovative technologies, practical design, and robust construction. Its advanced heating solutions cater to a wide range of commercial and industrial applications, making it a preferred choice for those seeking efficient and effective heating solutions in larger spaces. The combination of direct infrared heating, effective reflector systems, adaptability in installation, and user-friendly controls distinguishes the TF-Series as a market leader in heating technology.