York YMA024 warranty Footnotes, Procedures

Page 3

036-21570-002 Rev. D (0605)

Additional R-22 Charge / TXV Size for Various Matched Systems

Outdoor Unit

 

YMA02411

YMA03011

YMA03611

YMA04211

YMA04811

YMA06011

Unit Orifice (s)

 

63

69

78

87

-

96

Approved System Thermal Expansion Valve1,2

1TV0701

1TV0701

1TV0702

1TV0702

1TV0703

-

Factory R-22 Charge, lbs-oz

 

7 - 2

7 - 12

8 - 6

8 - 12

9 - 1

14 - 2

 

 

 

 

 

 

 

 

Indoor Coil3

Coil Orifice 4

 

 

Orifice - Additional Charge, Oz

 

 

G2FD030(S,H)17

65

63/(701) + 2

69/(701) + 0

 

-

-

-

G2FD035(S,H)14

65

63/(701) + 2

69/(701) + 0

 

-

-

-

G2FD036(S,H)17

65

-

-

78/(702) + 3

-

-

-

G2FD036(S,H)21

75

-

-

78/(702) + 5

-

-

-

G2FD048(S,H)21,24

84

-

-

-

87/(702) + 3

-

-

G2FD060(S,H)24

90

-

-

-

-

703 + 6

96 + 6

G2FD061H24

90

-

-

-

-

703 + 12

96 + 12

G1HA036H14

75

63/(701) + 8

69/(701) + 6

78/(702) + 5

-

-

-

G1HA036H17

78

63/(701) +12

69/(701) + 9

78/(702) + 8

-

-

-

G1HA048H21

84

-

-

-

87/(702) + 4

-

-

G1HA060H24

90

-

-

-

-

703 + 6

96 + 6

G1HD036

69

63/(701) + 8

69/(701) + 5

78/(702) + 5

-

-

-

G1HD048

81

-

-

-

87/(702) + 0

-

-

G1HD060

93

-

-

-

-

703 + 0

96 + 0

G1NA036S17J

67

63/(701) + 4

69/(701) + 2

78/(702) + 1

-

-

-

G1NA036S21C

67

63/(701) + 4

69/(701) + 2

78/(702) + 1

-

-

-

G1NA060S24T

87

-

-

-

87/(702) + 8

703 + 1

96 + 0

G1FA/G1UA036S14

73

63/(701) + 4

69/(701) + 2

78/(702) + 1

-

-

-

G1FA/G1UA036S17,21

73

63/(701) + 2

69/(701) + 0

78/(702) + 0

-

-

-

G1FA/G1UA048S21

84

-

-

-

87/(702) + 5

-

-

G1FA/G1UA060S21,24

90

-

-

-

-

703 + 6

96 + 6

F2RC/F2FC036

75

63/(701) + 2

69/(701) + 0

-

-

-

-

F2RP024

61

63/(701) + 0

-

-

-

-

-

F2RP/F2FP030

65

63/(701) + 2

69/(701) + 0

-

-

-

-

F2RP/F2FP036

75

-

-

78/(702) + 5

-

-

-

F2FP040

63

-

-

78/(702) + 8

-

-

-

F2RP/F2FP042

78

-

-

78/(702) + 8

-

-

-

F2FP045

78

-

-

-

-

703 + 6

-

F2FP048

84

-

-

-

87/(702) + 7

-

-

F2FP060

90

-

-

-

-

703 + 6

96 + 6

F2FV060

90

-

-

-

-

703 + 6

96 + 6

Indoor Coil with factory

Factory installed

 

 

Additional Charge, Oz.

 

 

installed TXV2,4

coil orifice3

 

 

 

 

 

 

 

 

 

 

G2FD030(S,H)17T

-

2

0

 

-

-

-

G2FD035(S,H)14T

-

2

0

 

-

-

-

G2FD036(S,H)17T

-

-

-

3

-

-

-

G2FD036(S,H)21T

-

-

-

5

-

-

-

G2FD060(S,H)24T

-

-

-

-

-

6

-

G1HA036H14T

-

-

-

5

-

-

-

G1HA036H17T

-

-

-

8

-

-

-

G1HA060H24T

-

-

-

-

-

6

-

G1FA/G1UA036S14T

-

-

-

1

-

-

-

G1FA/G1UA036S17,21T

-

-

-

0

-

-

-

G1FA/G1UA060S21,24T

-

-

-

-

-

6

-

F3RP024

-

0

-

-

-

-

-

F3RP030

-

2

0

-

-

-

-

F3RP036

-

-

-

5

-

-

-

F3RP042

-

-

-

8

-

-

-

F3FP040

-

-

-

8

-

-

-

F3FP060

-

-

-

-

-

6

-

F3FV060

-

-

-

-

-

6

-

FOOTNOTES:

 

 

 

 

 

 

 

1Only the TXV kits listed above are approved for use in these systems. The charge adder is the same as that listed for the orifice.

2Models with reciprocating compressors require start kits when matched to TXV indoor coils.

3Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.

4These orifices or TXVs are factory mounted in the flow device of each indoor coil (701, 702, 703 indicates 1TV07…series). A “T” suffix indicates a coil or air handler with a factory mounted TXV.

PROCEDURES:

1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter- connecting line tubing.

2.Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.

3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified on the previous page.

4.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.

Unitary Products Group

3

Image 3
Contents Warranty FeaturesDescription Physical and Electrical Data DimensionsFootnotes ProceduresCooling Capacity With Air Handler Coils + TDR Unit Model FurnaceTXV +TDR2 Cooling Capacity With Variable Speed FurnacesTXV +TDR TXV +TDR5 Unit AIR COIL1 ARI HEATING2 Outdoor TEMP3 Model Handler Heating Performance With Air HandlerUnit COIL1 ARI HEATING2 Outdoor TEMP3 Model Heating Performance Furnace CoilsColor Grilles AccessoriesSound Power Ratings Performance Multipliers for Small Vapor Line DiametersAir Handler Coil Cooling Performance DataYMA02411 G2FD030S17YMA03011 G2FD036S17 YMA03611G1FA048S21 YMA04211G2FA060S24 YMA04811YMA06011 Unit Coil Heating Performance DataEntering Outdoor IndoorF2RP/F2FP/F3FP030 N1AHB08 41.2 42.8 G2FD048S21 G1FA060S24 68.6 69.0 ADD-ON Coils for Furnace Applications Matching Indoor ComponentsUnitary 5005 Norman Products York Group Drive 73069

YMA024 specifications

The York YMA024 is a robust and efficient air conditioning system designed to deliver optimal cooling and comfort in both residential and commercial settings. This model is renowned for its advanced technology and user-friendly features, making it a preferred choice among HVAC professionals and property owners alike.

One of the standout features of the YMA024 is its high-efficiency compressor, which operates using advanced refrigerant management systems. This not only enables superior cooling performance but also ensures lower energy consumption. The unit is engineered with a SEER (Seasonal Energy Efficiency Ratio) rating that meets or exceeds industry standards, allowing users to enjoy significant savings on energy bills while contributing to a greener environment.

The YMA024 employs a variable-speed fan that adjusts its operation based on the cooling demand. This innovation enhances the overall comfort by reducing temperature fluctuations while also minimizing energy usage. The system is designed for quiet operation, making it suitable for various applications, from bustling office environments to serene residential spaces.

In terms of build quality, the YMA024 features a durable, corrosion-resistant cabinet. This ensures longevity and reliable performance even in harsh weather conditions. Additionally, the unit incorporates advanced insulation to reduce noise levels and improve efficiency, creating a comfortable indoor atmosphere.

Another critical aspect of the York YMA024 is its advanced control options. Users can choose from multiple thermostats, including smart and programmable models, allowing for seamless integration into modern smart home systems. This flexibility facilitates remote access and monitoring, empowering users to manage their cooling needs efficiently.

York places a strong emphasis on ease of maintenance with the YMA024. The model is designed with accessible paneling, making routine inspections and service calls less time-consuming. The unit's filter system is easily replaceable, ensuring clean air circulation and maintaining optimal indoor air quality.

Overall, the York YMA024 stands out as a high-performance, energy-efficient air conditioning solution. It combines cutting-edge technology, robust construction, and user-friendly features, making it an excellent investment for anyone seeking reliable climate control. Whether for a single-family home or a larger commercial facility, the YMA024 provides exceptional cooling performance that meets the demands of today’s diverse environments.