Toshiba RAV-SP360AT2-UL, RAV-SP300AT2-UL, RAV-SP420AT2-UL installation manual Dimension, Discharge

Page 3

Outdoor Unit

Installation Manual

1

DIMENSION

 

 

 

 

0.7"(17.5)

5.0"(128)

 

Air intake

 

 

Drain hole

 

 

 

 

 

15.0"(380)

 

 

(Ø1.0"(25) burring hole)

 

 

 

 

 

 

 

 

 

 

 

 

7.9"(200)

2.4"(60)

B legs

 

 

 

 

 

 

 

 

 

 

 

14.4"(365)

4.6"(118)

Air intake

 

1.8"(46)

1.3"(34)

6.7"(170)

1.9"(48)

2.1"(54)

 

 

 

 

 

 

 

 

 

 

0.7"(17.5)

 

 

3.0"(75)

 

 

 

 

 

 

2.9"(74)

 

Air

 

A legs

 

 

 

 

 

 

discharge

 

 

 

 

 

 

 

 

15.1"(383)

2.8"(70)

1.5"(39)

5-drain hole

 

 

5.9"(150)

 

23.6"(600)

 

3.8"(96)

Ø0.8"(20) ~ 3.5"(88)

 

 

 

 

 

 

 

 

burring hole

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35.4"(900)

 

 

 

 

 

 

2.0"(52)

21.7"(550)

 

 

 

 

0.5"(12)

1.6"(40)

Mounting bolt hole

(Ø0.5"(12) × 0.7"(17) U-shape hole)

 

Details of B legs

1.6"(40)

Mounting bolt hole

(Ø0.5"(12) × 0.7"(17) long hole)

 

Details of A legs

12.6"(320)

 

21.0"(534)

 

22.9"(581)

25.8"(655)

 

4.8"(121)

2.9"(74)

14.2"(360)

21.0"(534)

 

22.9"(581)

Refrigerant pipe connecting port (Ø0.4”(9.5) flare at liquid side)

Refrigerant pipe connecting port (Ø0.6”(15.9) flare at gas side)

1.2"(30)

Conduit connection hole

 

 

Refrigerant piping

 

 

knockout

 

23.8"(605)

24.1"(613)

5.1"(130)

2.0"(50)

52.8"(1340)

3.7"(95)

3.3"(85)

2.7"(70)

2.4"(60)

7"(178)

7"(178)

7"(178)

Z

0.3"(7)

2.2"(56)

3.4"(85)

0.7"(18)

2.3"(58)

1.0"(24)

2.2"(55)

 

 

2.7"(68)

20.4"(518)

 

 

 

 

3.9"(99)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12.9"(327)

 

 

 

 

 

 

15.7"(400)

 

0.5"(12)

 

 

 

 

 

3.3"(83)

0.3"(7)

 

 

 

 

 

 

 

Mounting hole sold separately

 

 

 

 

 

 

 

 

 

 

 

(24 - Ø0.1"(3) emboss)

 

 

 

 

2.6"(65)

 

 

 

 

 

 

 

 

 

Knockout for bottom piping

Z views

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant piping knockout

2.5"(64)

EN

– 2 –

2-EN

Image 3
Contents Installation manual Contents Discharge DimensionAccessory Parts „ Piping Field supplied System RequirementsBe sure to ground the equipment Precautions for SafetyEquipment Damage Hazard Installation of NEW Refrigerant AIR Conditioner „ Required Tools/Equipment and Precautions for UseNew Refrigerant Air Conditioner Installation „ Installation Location Do not install the outdoor unit in the following locationExample Upper side is free Above unit is free „Required ClearancesUnit in mm Barrier at rear side Barrier in frontBarriers in front and back of unit „ Installation of Outdoor UnitStandard installation Installation ManualNo Good „ For ReferenceFlaring diameter size a Unit in mm Refrigerant PipingFlaring Projection margin in flaring B Unit in mm Rigid Clutch type„Tightening of Flare ConnectionsDo not apply refrigerant oil to the flared surface Electrical Connections „ Field wiring„Wiring Attach the front pipe cover with 4 screws Triple Evacuation Method Using Vacuum PumpEvacuate and Dehydrate the System Deep Vacuum MethodLiquid side Open service valvesValve handling precautions Final Tubing Check11PERIODIC Maintenance Finishing10TEST RUN Verifying Error code status Outdoor control board 12TROUBLESHOOTINGD800 D801 D802 D803 D804 D805 14POWER Save Procedure13UNIT Pump Down EH99865501

RAV-SP420AT2-UL, RAV-SP300AT2-UL, RAV-SP360AT2-UL specifications

Toshiba has established itself as a leader in HVAC technology, providing solutions that cater to diverse climate control needs. Among its notable models are the Toshiba RAV-SP300AT2-UL, RAV-SP420AT2-UL, and RAV-SP360AT2-UL. Each of these units is designed to deliver efficient cooling and heating, suitable for both residential and commercial applications.

The RAV-SP300AT2-UL is a compact air conditioning unit that emphasizes energy efficiency. With a cooling capacity of 30,000 Btu/h and a heating capacity that mirrors this output, the unit is an ideal choice for moderate-sized spaces. One of its key features is the use of inverter technology, which allows the compressor to adjust its speed according to the cooling demand. This not only reduces energy consumption but also ensures a consistent indoor climate.

Moving to the RAV-SP420AT2-UL, this model offers higher performance with a cooling capacity of 42,000 Btu/h. It maintains energy efficiency while providing robust climate control capabilities. The RAV-SP420AT2-UL is equipped with advanced filtration systems that enhance indoor air quality by removing dust, allergens, and other pollutants. Additionally, the unit features a quiet operation mode that minimizes noise, making it suitable for environments where comfort and tranquility are paramount.

The RAV-SP360AT2-UL occupies a middle ground with a cooling capacity of 36,000 Btu/h. Like its counterparts, it harnesses inverter technology for optimum efficiency. This model is particularly noted for its versatility, as it can effectively serve a wide range of commercial applications. It also boasts smart technology integration, allowing users to control their HVAC systems remotely via smartphones or smart home systems.

All three models are constructed with durable materials designed to withstand varying weather conditions. They also feature a self-diagnostic system that assists technicians in identifying issues quickly, thereby minimizing downtime. Furthermore, Toshiba's commitment to sustainability is evident in these units, as they are designed with eco-friendly refrigerants that comply with global environmental standards.

In conclusion, Toshiba's RAV-SP300AT2-UL, RAV-SP420AT2-UL, and RAV-SP360AT2-UL represent the forefront of HVAC innovation. With their unique features, energy efficiency, and advanced technologies, these air conditioning systems provide reliable performance tailored to the needs of users, ensuring comfort and satisfaction in any environment.