Toshiba RAS-07PKVP-E owner manual AIR Conditioner Operation and Performance

Page 25

AIR CONDITIONER OPERATION AND PERFORMANCE

Three-minute protection feature

A protection feature is provided that prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation or when the power supply switch is set to on. This is used to protect the machine.

Heating characteristics

Preheating operation

The air conditioner does not deliver warm air immediately after it is started.

Warm air flows out after approximately 5 minutes when the indoor heat exchanger has warmed up.

Warm air control

When the room temperature reaches the temperature setting, the fan indoor speed is automatically reduced. The outdoor unit is stopped at this time.

Defrosting

If frost has formed on the outdoor unit during the heating operation, defrosting is started automatically (for approximately 5 to 10 minutes) to maintain the heating effect.

The fans in both the indoor and outdoor units stop during the defrost operation.

During the defrost operation, defrosted water is drained from the bottom plate of the outdoor unit.

Heating capacity

In the heating operation, heat is absorbed from outdoors and released into the room. That is called the heat pump system. When the outdoor temperature is too low, usage of another heating apparatus in combination with the air conditioner is recommended.

Consideration for accumulated snow

Select the position for the outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris. It is important that the air flow of the outdoor unit is not blocked as this will result in reduced heating or cooling performance. During the heating mode and at sub-zero temperatures, the water drained off the outdoor unit as a result of the automatic defrost may accumulate and freeze. It is important that adequate drainage or a soak-way be provided.

CAUTION (RAS-***-ND model only)

A heater is installed on the base plate of the outdoor unit. When the outside air temperature is low, the heater runs to warm the base plate even if the unit is not operating so that snow does not accumulate inside the outdoor unit. Do not use the supplied drain nipple for draining water. Drain the water from all the drain holes directly. Provide a space of at least 50 cm under the outdoor unit so that the draining water does not freeze and block the drain holes.

Power failure

Power failure during operation stops the unit completely.

The OPERATION indicator (green) on the indoor unit starts flashing when power is restored.

To restart operation, push the button on the remote controller.

Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Turn the power supply switch off and then on again. Push the button on the remote controller to restart.

Air conditioner operating conditions

For proper performance, operate the air conditioner under the following temperature conditions.

Cooling operation

Outdoor temperature:

–10°C to 46°C

 

Room temperature:

21°C to 32°C

CAUTION

Room relative humidity — less than 80%. If the air conditioner operates outside this range, the surface of the air conditioner may attract condensation.

Heating operation

Outdoor temperature:

–15°C to 24°C

 

Room temperature:

Less than 28°C

 

 

 

Dry operation

Outdoor temperature:

–10°C to 46°C

 

 

 

 

Room temperature:

21°C to 32°C

 

 

 

8°C Heating

Setting temperature:

5°C to 13°C

If the air conditioner is used in conditions other than above, the safety protection functions may be activated.

23

EN

Image 25
Contents AIR Conditioner Split Type Contents Precaution for Safety AccessoriesPage Page Names of Parts Reset buttonOutdoor unit Indoor unitRemote Controller and ITS Functions Display Names and Functions of Indicators on Remote ControllerPreparation and Check Before USE Clock button Adjusting the clockLocation of the remote controller Using the Remote ControllerRemote controller holder Types of signal receiving tonesAutomatic Operation Auto Changeover Automatic OperationStart StopDRY Operation COOLING/HEATING Operation8C button 8C Operation RAS-***-ND model onlyPure Operation On timer and OFF timer Setting the on Timer Timer OperationSetting OFF Timer Cancelling timer operation On timer OFF timer Stop Operation StopSetting combined Timer Clock displayMEMORY/MY Comfort Operation When the MY Comfort button is pressed during operationMemo button Adjusting AIR Flow Direction Auto Restart Operation Green indicator flashes for 5 secondsSleep Mode operation Hi Power operationHOW the AIR Conditioner Works Automatic OperationTemporary Operation Cleaning OperationCleaning of indoor unit and remote controller Usual MaintenanceWhen not using the unit for at least 1 month Cleaning the air filterPush AIR Conditioner Operation and Performance Recheck Inoperative TroubleshootingPoor cooling or heating performance Indoor unit or outdoor unit makes a strange noise Operation indicator turns on and offRoom air smells Bad odor comes from the air conditioner Automatic operation of vertical air flow louversSounds made from the indoor unit These are not defects Pure indicator Orange turns onSounds made from the outdoor unit Signal Receiving Tone Does Not Sound Remote controller does not operate correctlyDisplay Goes Off Reverse cycle, Split type SpecificationsFor heating Air inlet temperature C For cooling Air inlet temperature CToshiba Carrier Corporation

RAS-07PKVP-E specifications

The Toshiba RAS-07PKVP-E is a cutting-edge air conditioning unit designed to provide efficient cooling and heating for residential and commercial spaces. This model is part of Toshiba's extensive range of HVAC solutions, reflecting the company's commitment to innovation, energy efficiency, and user comfort.

One of the standout features of the RAS-07PKVP-E is its inverter technology. This advanced system allows the unit to adjust its cooling or heating output depending on the current indoor conditions, which not only enhances comfort but also significantly reduces energy consumption. Inverter air conditioners are known for their ability to maintain a stable temperature while consuming less electricity compared to conventional units.

In terms of cooling capacity, the Toshiba RAS-07PKVP-E has a nominal capacity of 2.0 kW, making it suitable for small to medium-sized rooms. The unit operates quietly, thanks to its advanced engineering and design, ensuring that your living or working environment remains peaceful. This is particularly beneficial in bedrooms or offices where noise levels must be kept low.

The RAS-07PKVP-E also boasts a refrigerant that is environmentally friendly. The use of R32 refrigerant not only improves overall energy efficiency but also minimizes the impact on the environment, aligning with global efforts towards sustainability. This refrigerant has a lower Global Warming Potential (GWP), making it a responsible choice for eco-conscious consumers.

Additionally, the Toshiba RAS-07PKVP-E comes equipped with a range of convenient features including a user-friendly remote control, programmable timers, and multiple modes of operation, allowing users to customize their comfort according to specific needs and preferences. It also includes a sleep mode, which gradually adjusts the temperature for optimal comfort during sleeping hours.

The unit is designed with durability in mind, featuring a compact and sleek design that can easily blend into various interior styles. With its robust build quality, the RAS-07PKVP-E promises reliable performance over its lifespan, backed by Toshiba's reputation for excellence in engineering and manufacturing.

In conclusion, the Toshiba RAS-07PKVP-E offers an impressive combination of energy efficiency, advanced technology, and user-friendly features, making it an ideal choice for anyone looking to enhance their indoor climate with a modern air conditioning solution. Whether you're seeking relief from the summer heat or a cozy warmth during winter, this model stands out as a reliable and efficient option.