York YOCC-YOHC 12-60 owner manual Indoor Unit Installation, Ceiling Installation

Page 3

CEILING INSTALLATION

Hanging arm

Chart 7

1.Remove the side board and the grille. (Refer to Chart 8)

(For models 48000 and 60000 Btu/h, do not remove the grille.)

Side board

Grille

Chart 8

2.Locate the hanging arm on the hanging screw bolt. (Refer to Chart 9) Prepare the mounting bolts on the unit. (Refer to Chart 10)

25mm

 

8•• 13mm

 

 

20••

Screw nut

 

Washer

 

 

Hanging

 

 

screw bolt

Mounting bolt (max. 40 mm)

 

 

 

Hanging arm

 

 

Chart 9

Chart 10

3.Hang the unit on the hanging arm by sliding backward. Securely tighten the mounting bolts on both sides. (Refer to Chart 9)

Hanging screw bolt

Hanging arm

Mounting bolt

D. Connecting point of refrigerant pipe

 

(D. gas side)

 

E. Connecting point of refrigerant pipe

>20mm

(E. Liquid side)

 

Drain point

Chart 11

ATTENTION: The figures above are based on model with 18000 Btu/h as rated capacity, which may differ from the unit you purchased.

The dimension of the unit

Capacity

A

B

C

D

E

F

G

H

(Btu/h)

 

 

 

 

 

 

 

 

12000-24000 Btu/h

990

660

206

505

506

907

200

203

36000 Btu/h

1280

660

206

795

506

1195

200

203

48000-60000 Btu/h

1670

680

244

1070

450

1542

200

240

Note: The dimension of 12000 Btu/h and 24000 Btu/h are the same The dimension of 48000 Btu/h and 60000 Btu/h are the same

Outdoor unit

❥✱YODC-YOJC 12

❥✱YODC-YOJC 18

❥✱YODC-YOJC 24

 

285

750

 

845

313

895

300

 

 

301.5

 

 

 

 

 

590

695

 

860

 

 

 

 

351.2

 

 

 

 

 

 

135

 

163

590

 

 

62

141.5

560.1

 

 

 

235

 

 

 

 

 

 

 

 

 

315

290

335

125

330

 

 

❥✱YODC-YOJC 30-36

❥✱YODC-YOJC 48-60

 

 

 

 

 

990

336.4

400

 

 

940

 

 

 

 

960

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1245

 

 

 

 

 

 

181.4

624

 

 

 

 

 

 

 

 

 

360

 

 

 

 

 

 

 

 

 

 

 

 

 

 

360

 

 

 

 

 

 

❥✱DC Inverter R-410A

 

 

 

650

 

 

 

 

 

 

 

MODEL

A

B

C

D

E

H REMARK

 

 

H

18

840

550

335

360

310

677

 

 

 

 

24

894

590

333

355

302

860

R-410A

 

 

 

36

990

624

366

396

340

960

 

 

 

 

 

 

A

48

940

600

376

400

340

1245

 

 

 

B

 

 

 

 

 

 

 

 

D C

 

E

 

 

 

 

 

 

 

 

INSTALLATION IN THE FOLLOWING PLACES

MAY RESULT IN TROUBLE

Installation of the indoor unit in direct sun light.

Installation in the unit in wrong direction.

Installation of outdoor units too close or,

Installation of the indoor unit in a place where

blowing discharged air into each other.

there is an obstacle near the air inlet or outlet.

 

> 30 cm

Installation of the outdoor unit in a place

Installation of the indoor unit at too high > 30 cm

exposed regularly to a strong wind.

a position.

INDOOR UNIT INSTALLATION

Installing Ø10 hanging screw bolts. (4 bolts)

Please refer to the following figure for the distance measurement between the screw bolts.

Please install with Ø10 hanging screw bolts.

The handling to the ceiling varies from the constructions, consult the construction personnels for the specific procedures.

1.The size of the ceiling to be handled ... ... do keep the ceiling flat. Consolidate the roof beam for possible vibration.

2.Cut off the roof beam.

3.Strengthen the place cut off, and consolidate the roof beam.

Carry out the pipe and line operation in the ceiling after finishing the installation of the main body. While choosing where to start the operation, determine the direction of the pipes to be drawn out. Especially in case there is a ceiling, position the refrigerant pipes, drain pipes, indoor & outdoor lines to the connection places before hanging up the machine.

The installation of hanging screw bolts.

530 110

Image 3
Contents Extended Parts Safety PrecautionsPart List Required ToolsSelection of the Location Preparation Before InstallationInstallation Installation SiteDimension of the unit Capacity Btu/h Indoor Unit InstallationCeiling Installation Installation in the Following Places MAY Result in TroubleConnect the Drain Pipe WiringFor 18000-24000 Btu/h 36000~60000 Btu/h 3 PhaseDC Inverter R-410A Cooling OnlyRefrigerant Piping Connections Flare Connections Troubleshooting GuideTest Operation Maximum Piping LengthsTechnical Specification MaintenanceFloor/Ceiling Yohc YOKC-YOJCR-410A 50Hz Rev.291106 Floor/Ceiling DC Inverter Yohc R-410A, 50HzDE Commissioning Dismantling & Disposal

YOCC-YOHC 12-60 specifications

The York YOCC-YOHC 12-60 is a versatile and efficient HVAC solution designed to meet the demands of modern commercial applications. This innovative system combines robust engineering with advanced technology to deliver optimal comfort and energy savings.

One of the standout features of the YOCC-YOHC series is its energy efficiency. The units are equipped with high-efficiency compressors that utilize variable speed technology, allowing for precise control over cooling and heating output. This means that the system can adjust its capacity based on the specific requirements of the space, ensuring minimal energy consumption while maintaining a comfortable indoor environment.

Additionally, the YOCC-YOHC series incorporates advanced thermal management technologies. The units are designed with enhanced heat exchangers that improve heat transfer efficiency. This not only contributes to faster cooling and heating responses but also minimizes energy losses, making the system a sustainable choice for environmentally conscious users.

In terms of characteristics, the YOCC-YOHC units feature a robust construction designed to withstand harsh weather conditions. The exterior casing is constructed from durable materials that offer excellent resistance to corrosion and wear, ensuring a long service life. Furthermore, these units are designed for quiet operation, minimizing noise levels to enhance the overall comfort of the building occupants.

The YORK YOCC-YOHC range also boasts advanced control technologies. Users can take advantage of smart thermostats and building management system integrations, allowing for remote monitoring and control of the HVAC system. This capability not only simplifies operation but also provides valuable data insights that can be used to further optimize energy use and system performance.

Furthermore, the YOCC-YOHC series is designed with a focus on ease of installation and maintenance. Modular designs allow for simplified service access, reducing downtime and service costs.

In conclusion, the York YOCC-YOHC 12-60 stands out in the commercial HVAC market for its energy efficiency, durable construction, advanced thermal management technologies, and user-friendly controls. It's an ideal choice for businesses seeking a reliable and efficient solution to their heating and cooling needs, ensuring comfort while maximizing energy savings.