Blower Performance CFM - Any Position (without filter)

 

 

 

Bottom Airflow Data (SCFM)

 

 

 

 

 

 

 

Models

Speed

 

 

 

Ext. Static Pressure (in. H2O)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

0.2

0.3

0.4

 

0.5

0.6

0.7

0.8

 

0.9

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

1492

1442

1378

1325

 

1243

1176

1075

966

 

849

655

TM9T060B12MP11

Medium High

1236

1201

1161

1139

 

1082

1011

919

830

 

715

590

Medium Low

986

950

961

916

 

872

831

757

703

 

600

510

 

 

 

 

Low

824

795

783

744

 

713

659

624

554

 

489

389

 

High

1597

1537

1484

1435

 

1370

1286

1230

1155

 

1075

925

TM9T080B12MP11

Medium High

1338

1307

1273

1223

 

1179

1123

1065

998

 

928

812

Medium Low

1113

1094

1077

1043

 

1008

972

924

868

 

803

798

 

 

 

 

Low

937

916

900

877

 

854

817

775

718

 

639

560

 

High

1919

1865

1802

1738

 

1671

1600

1517

1414

 

1322

1201

TM9T080C16MP11

Medium High

1532

1533

1513

1499

 

1465

1416

1352

1283

 

1198

1084

Medium Low

1232

1313

1291

1280

 

1250

1209

1207

1148

 

1055

937

 

 

 

 

Low

826

821

853

858

 

838

817

794

776

 

760

711

 

High

1909

1880

1823

1776

 

1706

1637

1562

1474

 

1375

1252

TM9T100C16MP11

Medium High

1465

1463

1469

1485

 

1477

1416

1386

1324

 

1250

1114

Medium

1190

1222

1216

1215

 

1224

1189

1158

1145

 

1087

996

 

 

 

 

Low

787

834

819

836

 

819

810

790

761

 

690

707

 

High

2284

2205

2114

2021

 

1934

1848

1752

1653

 

1505

1397

TM9T100C20MP11

Medium High

1967

1905

1824

1763

 

1712

1628

1551

1473

 

1379

1213

Medium Low

1610

1563

1513

1480

 

1430

1367

1319

1261

 

1101

1012

 

 

 

 

Low

1326

1304

1267

1232

 

1183

1143

1080

1003

 

871

798

 

High

2341

2245

2153

2072

 

1977

1876

1769

1642

 

1506

1306

TM9T120D20MP11

Medium High

2002

1952

1878

1823

 

1739

1657

1563

1458

 

1322

1185

Medium Low

1615

1579

1533

1473

 

1430

1368

1282

1186

 

1091

953

 

 

 

 

Low

1352

1295

1259

1245

 

1190

1141

1076

998

 

938

820

 

 

 

Left Side

Airflow Data (SCFM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

Speed

 

 

 

Ext. Static Pressure (in. H2O)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

0.2

0.3

0.4

 

0.5

0.6

0.7

0.8

 

0.9

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

1470

1406

1361

1309

 

1241

1155

1060

920

 

775

628

TM9T060B12MP11

Medium High

1211

1186

1139

1101

 

1042

980

896

796

 

681

545

Medium Low

970

957

927

889

 

853

796

745

660

 

568

450

 

 

 

 

Low

793

781

756

724

 

694

653

585

530

 

469

382

 

High

1605

1562

1514

1454

 

1393

1330

1251

1169

 

1073

940

TM9T080B12MP11

Medium High

1372

1318

1280

1255

 

1205

1161

1093

1023

 

943

849

Medium Low

1087

1073

1052

1003

 

993

953

897

843

 

775

709

 

 

 

 

Low

916

896

881

854

 

831

802

757

708

 

642

574

 

High

1956

1907

1846

1778

 

1717

1647

1573

1483

 

1353

1209

TM9T080C16MP11

Medium High

1543

1543

1516

1504

 

1477

1446

1382

1309

 

1202

1099

Medium Low

1238

1241

1243

1241

 

1252

1242

1201

1140

 

1074

967

 

 

 

 

Low

906

902

903

910

 

888

866

859

829

 

795

743

 

High

1828

1829

1789

1768

 

1727

1671

1601

1505

 

1390

1272

TM9T100C16MP11

Medium High

1422

1444

1437

1424

 

1396

1326

1301

1253

 

1200

1100

Medium

1224

1229

1243

1234

 

1219

1193

1168

1135

 

1088

977

 

 

 

 

Low

813

819

818

814

 

783

762

756

732

 

690

642

 

High

2391

2286

2165

2079

 

2004

1934

1839

1692

 

1560

1366

TM9T100C20MP11

Medium High

1945

1878

1838

1782

 

1694

1642

1565

1451

 

1334

1163

Medium Low

1549

1530

1495

1430

 

1431

1365

1284

1192

 

1097

1022

 

 

 

 

Low

1256

1229

1189

1159

 

1089

1033

1008

950

 

871

784

 

High

2343

2253

2167

2071

 

1979

1881

1785

1668

 

1473

1351

TM9T120D20MP11

Medium High

1954

1892

1846

1781

 

1714

1637

1548

1429

 

1238

1171

Medium Low

1596

1539

1511

1458

 

1399

1341

1254

1180

 

942

988

 

 

 

 

Low

1299

1261

1229

1177

 

1111

1053

993

937

 

882

782

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Airflow expressed in standard cubic feet per minute (CFM).

 

 

 

 

 

 

 

 

 

 

2. Return air is through side opposite motor (left side).

 

 

 

 

 

 

 

 

 

 

 

3. Motor voltage at 115 V.

 

 

 

 

 

 

 

 

 

 

 

 

4. Airflow through across motor side (right side) may be slightly less than the data shown above.

 

 

 

 

 

 

Subject to change without notice. Printed in U.S.A.

 

 

 

 

 

 

 

 