York YP9C*C warranty Filter Performance, Accessories

Page 3

FILTER PERFORMANCE

The airflow capacity data published in the “Blower Perfor- mance” table represents blower performance WITHOUT filters.

All applications of these furnaces require the use of field installed air filters. All filter media and mounting hardware or provisions must be field installed external to the furnace cabi- net. DO NOT attempt to install any filters inside the furnace.

NOTE: Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer’s rec- ommendation and a transition is used to allow use of a 20 x 25 filter.

Recommended Filter Sizes

CFM

Cabinet

Side

Bottom

Size

(in)

(in)

 

 

 

 

 

1200

B

16 x 25

16 x 25

 

 

 

 

1600

C

16 x 25

20 x 25

 

 

 

 

2000

C

(2) 16 x 25

20 x 25

 

 

 

 

2000

D

(2) 16 x 25

22 x 25

 

 

 

 

NOTES:

1.Air velocity through throwaway type filters may not exceed 300 feet per min- ute (91.4 m/min). All velocities over this require the use of high velocity fil- ters.

2.Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter.

Unit Clearances to Combustibles

Application

Upflow

Downflow

Horizontal

Top

1"

0"

0"

Vent

0"

0"

0"

Rear

0"

0"

0"

Side

0"

0"

1"

Front1

0"

0"

0"

Floor

Combustible

Combustible2

Combustible

Closet

Yes

Yes

Yes

 

 

 

 

Line Contact

No

No

Yes

 

 

 

 

1.Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and building joists, studs or framing.

2.For combustible floors only when used with special sub-base.

All furnaces approved for alcove and attic installation.

ACCESSORIES

Propane (LP) Conversion Kit -

1NP0681 - All Models

This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation.

Do not use Conversion Kit S1-1NP0680 with these models, as the control/gas valve combination have been updated, and that kit S1-1NP0680 will not function correctly with these models.

Concentric Vent Termination -

S1-1CT0302 (2")

S1-1CT0303 (3")

For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through single common hole. Elimi- nates unslightly elbows for a cleaner installation.

Johnson Controls Unitary Products

538513- YTG-A-0809

Sidewall Vent Termination Kit -

S1-1HT0901 (3")

S1-1HT0902 (2")

For use on sidewall, two-pipe installations only. Provide a more attractive termination for locations where the terminal is visable on the side of the home.

Condensate Neutralizer Kit -

1NK0301

Neutralizer cartridge has a 1/2" plastic tube fittings for installa- tion in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts (p/n 026-30228-000).

Side Return Filter Racks -

1SR0200 - All Models

1SR0402 - All Models

1SF0101 - All Models

Bottom Return Filter Racks -

1BR0517 or 1BR0617 - For 17-1/2” cabinets 1BR0521 or 1BR0621 - For 21” cabinets 1BR0524 or 1BR0624 - For 24-1/2” cabinets

1BR05xx series are galvanized steel filter racks. 1BR06xx are pre-painted steel filter racks to match the appearance of the fur- nace cabinet.

Combustible Floor Base Kit -

For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential overheating situations. These kits are also required in any applications where the furnace in installed in a downflow configuration without an evaporator coil, where the combustible floor base kit provides access for com- bustible airflow.

1CB0517 - For 17-1/2” cabinets 1CB0521 - For 21” cabinets 1CB0524 - For 24-1/2” cabinets

EAC Transition Kits -

For installation of EAC accessories with these furnaces to pro- vide easy transition of return airflow through the EAC to get the proper sealing and reduced airflow leakage.

1TK1001 - For all models using side return 1TK1017 - For 17-1/2” cabinets using bottom return 1TK1021 - For 21” cabinets using bottom return 1TK1024 - For 24-1/2” cabinets using bottom return

High Altitude - No high altitude kits are required.

Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and installation, refer to the UPGNET “Low Voltage Wiring Diagram” document to select and apply controls.

3

Image 3
Contents 60 120 MBH Input WarrantyFeatures DescriptionRatings & Physical / Electrical Data Cabinet and Duct DimensionsFilter Performance AccessoriesJohnson Controls Unitary Products York Drive Norman, OK 060B12*C 080B12*C Jumper Settings100C20*C 120D20*C Jumper Settings Blower Performance CFM Any Position

YP9C*C specifications

The York YP9C*C is a high-efficiency, wall-mounted gas condensing boiler designed for residential and commercial heating solutions. Known for its compact dimensions and advanced engineering, the YP9C*C is tailored to meet the increasing demands for energy-efficient heating systems while adhering to modern environmental standards.

One of the standout features of the YP9C*C is its impressive efficiency rating, often surpassing 90%. This efficiency is primarily due to its condensing technology, which captures and utilizes the heat from flue gases that would typically be wasted in conventional boilers. This feature not only reduces energy consumption but also minimizes greenhouse gas emissions, making it an eco-friendly choice for heating.

The boiler is equipped with an advanced modulating burner that adjusts the heat output based on the current heating needs of the space. This modulating feature helps in maintaining a consistent temperature while using less fuel, which results in cost savings for consumers. Furthermore, the YP9C*C also features a built-in frost protection mechanism, which prevents the boiler from freezing, ensuring reliability even in colder climates.

In terms of installation, the York YP9C*C boasts a lightweight and compact design, allowing for easier placement in various settings. It can be easily mounted on walls, saving valuable floor space, and is suitable for both new installations and retrofitting existing systems. The boiler also features a user-friendly interface with digital controls, making it simple for users to monitor and adjust settings as needed.

The YP9C*C supports a range of modern heating technologies, including smart home integration, which allows users to control their heating remotely via smartphone apps. This connectivity feature enhances convenience and energy management, contributing to overall efficiency.

Another important characteristic of the YP9C*C is its durability and reliability. Built with high-quality materials, the boiler is designed to withstand the rigors of daily use while providing dependable performance over the years. Additionally, it usually comes with a robust warranty, offering peace of mind to users regarding their investment.

Overall, the York YP9C*C condensing boiler stands out as a versatile and efficient solution for heating needs, combining advanced technology with user-friendly features and a commitment to sustainability.