York PV9 warranty AIR Flow Data, High / LOW Speed Cooling and Heat Pump CFM, Heat CFM

Page 4

036-21584-001 Rev. B (1004)

AIR FLOW DATA

 

 

 

 

HIGH / LOW SPEED COOLING AND HEAT PUMP CFM

 

 

 

 

 

40,000 INPUT - 3 Ton

 

 

 

60,000 INPUT - 3 Ton

 

JUMPER SETTINGS

CFM

 

m³/min

 

CFM

 

m³/min

 

 

 

 

 

 

 

High

 

Low

High

 

Low

High

 

Low

High

 

Low

COOL Tap

ADJ Tap

1340

 

995

38.0

 

28.2

1330

 

900

37.7

 

25.5

A

B

1205

 

885

34.1

 

25.1

1130

 

800

32.0

 

22.7

B

B

1255

 

920

35.6

 

26.1

1220

 

850

34.6

 

24.1

A

A

1150

 

835

32.6

 

23.7

1040

 

730

29.4

 

20.7

B

A

1170

 

855

33.2

 

24.2

1120

 

770

31.7

 

21.8

A

C

1025

 

755

29.0

 

21.4

920

 

650

26.1

 

18.4

C

B

1045

 

780

29.6

 

22.1

950

 

660

26.9

 

18.7

B

C

835

 

625

23.7

 

17.7

740

 

540

21.0

 

15.3

D

B

950

 

705

26.9

 

20.0

860

 

610

24.4

 

17.3

C

A

785

 

590

22.2

 

16.7

690

 

540

19.5

 

15.3

D

A

865

 

665

24.5

 

18.8

790

 

570

22.4

 

16.1

C

C

725

 

605

20.5

 

17.1

630

 

530

17.8

 

15.0

D

C

 

 

80,000 INPUT - 3 Ton

 

 

 

80,000 INPUT - 4 Ton

 

JUMPER SETTINGS

CFM

 

m³/min

 

CFM

 

m³/min

 

 

 

 

 

 

 

High

 

Low

High

 

Low

High

 

Low

High

 

Low

COOL Tap

ADJ Tap*

1310

 

890

37.1

 

25.2

1660

 

1110

47.0

 

31.4

A

B

1100

 

740

31.2

 

21.0

1550

 

1050

43.9

 

29.7

B

B

1220

 

830

34.6

 

23.5

1610

 

1070

45.6

 

30.3

A

A

1000

 

670

28.3

 

19.0

1440

 

960

40.8

 

27.2

B

A

1090

 

720

30.9

 

20.4

1470

 

990

41.6

 

28.0

A

C

900

 

610

25.5

 

17.3

1370

 

920

38.8

 

26.1

C

B

880

 

610

24.1

 

17.3

1290

 

850

36.5

 

24.1

B

C

680

 

510

19.3

 

14.4

1130

 

790

32.0

 

22.4

D

B

810

 

580

22.9

 

16.4

1230

 

850

34.8

 

24.1

C

A

630

 

500

17.8

 

14.2

1050

 

720

29.7

 

20.4

D

A

730

 

530

20.7

 

15.0

1110

 

760

31.4

 

21.5

C

C

590

 

500

16.7

 

14.2

950

 

660

26.9

 

18.7

D

C

 

 

100,000 INPUT - 5 Ton

 

 

 

120,000 INPUT - 5 Ton

 

JUMPER SETTINGS

CFM

 

m³/min

 

CFM

 

m³/min

 

 

 

 

 

 

 

High

 

Low

High

 

Low

High

 

Low

High

 

Low

COOL Tap

ADJ Tap*

2210

 

1480

62.6

 

41.9

2280

 

1510

64.6

 

42.8

A

B

1780

 

1180

50.4

 

33.4

1860

 

1190

52.7

 

33.7

B

B

2040

 

1350

57.8

 

38.2

2090

 

1370

59.2

 

38.8

A

A

1620

 

1050

45.9

 

29.7

1630

 

1060

46.2

 

30.0

B

A

1840

 

1250

52.1

 

35.4

1880

 

1250

53.2

 

35.4

A

C

1560

 

1010

44.2

 

28.6

1620

 

1030

45.9

 

29.2

C

B

1470

 

940

41.6

 

26.6

1500

 

960

42.5

 

27.2

B

C

1370

 

890

38.8

 

25.2

1410

 

880

39.9

 

24.9

D

B

1460

 

930

41.3

 

26.3

1490

 

920

42.2

 

26.1

C

A

1250

 

790

35.4

 

22.4

1290

 

790

36.5

 

22.4

D

A

1310

 

810

37.1

 

22.9

1360

 

840

38.5

 

23.8

C

C

1090

 

690

30.9

 

19.5

1140

 

690

32.3

 

19.5

D

C

 

 

 

 

 

 

HIGH / LOW

HEAT CFM

 

 

 

 

 

 

 

40,000 INPUT - 3 Ton

 

 

 

60,000 INPUT - 3 Ton

 

JUMPER SETTINGS

CFM

 

m³/min

 

CFM

 

m³/min

 

 

 

 

 

 

 

High

 

Low

High

 

Low

High

 

Low

High

 

Low

HEAT Tap

ADJ Tap*

1045

 

740

29.6

 

21.0

1110

 

710

31.4

 

20.1

A

Any

905

 

645

25.6

 

18.3

960

 

640

27.2

 

18.1

B

Any

825

 

595

23.4

 

16.8

870

 

600

24.6

 

17.0

C

Any

765

 

590

21.7

 

16.7

830

 

570

23.5

 

16.1

D

Any

 

 

80,000 INPUT - 3 Ton

 

 

 

80,000 INPUT - 4 Ton

 

JUMPER SETTINGS

CFM

 

m³/min

 

CFM

 

m³/min

 

 

 

 

 

 

 

High

 

Low

High

 

Low

High

 

Low

High

 

Low

HEAT Tap

ADJ Tap*

1330

 

880

37.7

 

24.9

1490

 

990

42.2

 

28.0

A

Any

1180

 

810

33.4

 

22.9

1350

 

900

38.2

 

25.5

B

Any

1100

 

730

31.2

 

20.7

1220

 

820

34.6

 

23.2

C

Any

1010

 

670

28.6

 

19.0

1120

 

770

31.7

 

21.8

D

Any

 

 

100,000 INPUT - 5 Ton

 

 

 

120,000 INPUT - 5 Ton

 

JUMPER SETTINGS

CFM

 

m³/min

 

CFM

 

m³/min

 

 

 

 

 

 

 

High

Low

High

Low

High

Low

High

Low

HEAT Tap

ADJ Tap*

1880

 

1230

53.2

 

34.8

2150

 

1420

60.9

 

40.2

A

Any

1670

 

1080

47.3

 

30.6

1930

 

1290

54.7

 

36.5

B

Any

1530

 

980

43.3

 

27.8

1850

 

1190

52.4

 

33.7

C

Any

1430

 

900

40.5

 

25.5

1660

 

1070

47.0

 

30.3

D

Any

All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c. external static pressure is not recommended.

NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic air cleaners. Consult the instructions for the electronic air cleaner for further details.

The ADJ “D” tap should not be used.

4

Unitary Products Group

Image 4
Contents Warranty FeaturesDescription Natural GASCombustion AIR Supply and Vent Piping Maximum Elbows and Vent LengthsModels Pipe Size Maximum Number of Elbows Minimum Inches cm LengthHigh Altitude Pressure Switch Application Electrical and Performance DataFilter Sizes Unitary Products GroupHigh / LOW Speed Cooling and Heat Pump CFM AIR Flow DataHeat CFM Filter Performance Applying Filter Pressure Drop to Determine System AirflowFilter Performance Pressure Drop Inches W.C. and KPA Washable FiberAccessories 036-21584-001 Rev. B Unitary Products Group Unitary 5005 Norman Products York Group Drive 73069

PV9 specifications

The York PV9 is a highly efficient and robust air conditioning unit well-suited for both residential and commercial applications. This model stands out due to its reliability, advanced features, and impressive energy efficiency ratings. Designed to cater to a variety of spaces, the PV9 is an ideal choice for homeowners, businesses, and institutional facilities.

One of the main characteristics of the York PV9 is its energy efficiency. It boasts a high Seasonal Energy Efficiency Ratio (SEER) rating, which allows it to provide considerable cooling power while consuming less electricity compared to traditional units. This efficiency not only translates to lower energy bills but also aligns with eco-friendly initiatives aimed at reducing carbon footprints.

Another key feature of the York PV9 is its variable-speed compressor technology. This innovative system enables the unit to adjust its cooling output based on the demand of the environment. As a result, the PV9 can maintain precise temperature control and enhance comfort while minimizing energy consumption. This variable-speed operation also leads to quieter performance, making it a preferable choice for residential areas or quiet office settings.

In addition to its energy efficiency, the York PV9 incorporates advanced air filtration technologies. The unit is equipped with a high-performance air filter that helps remove airborne allergens and particulate matter from the environment. This feature not only improves air quality but also contributes to the well-being of occupants, making it particularly beneficial for those with respiratory conditions or allergies.

Durability and design are also noteworthy aspects of the York PV9. Constructed with high-quality materials, this air conditioning unit is designed to withstand a range of weather conditions, ensuring sustained performance over the years. The sleek and modern design allows it to blend seamlessly into various architectural styles, adding aesthetic value to any space.

Moreover, the York PV9 is compatible with smart home systems, allowing users to control the unit remotely via smartphone applications. This added convenience gives users the ability to adjust settings and monitor energy usage from anywhere, providing both comfort and peace of mind.

In summary, the York PV9 air conditioning unit exemplifies cutting-edge technology, energy efficiency, and user-friendly features, making it an outstanding choice for those seeking dependable climate control solutions. With its combination of advanced compressor operation, high-efficiency ratings, superior air filtration, and durable design, the York PV9 sets a standard in the HVAC industry, promising comfort and sustainability for years to come.