TYPICAL INSTALLATION
| MINIMUM 18” SERVICE ACCESS | THERMOSTAT |
| |
60” OVERHEAD CLEARANCE ON ONE SIDE | TO FURNACE OR | |||
| ||||
|
| |||
CLEARANCE | WEATHERPROOF |
| AIR HANDLER | |
|
| |||
|
| TERMINAL BLOCK | ||
| DISCONNECT |
| ||
|
|
| ||
| SWITCH |
| NEC CLASS 1 WIRING | |
|
|
| NEC CLASS 2 WIRING | |
10” CLEARANCE |
|
|
| |
COIL AREA |
|
| TO INDOOR COIL | |
|
|
|
NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF.
SEAL OPENING(S) WITH
PERMAGUM OR EQUIVALENT
CONTROL ACCESS PANEL
TYPICAL FIELD WIRING
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES
POWER WIRING
POWER WIRING
24 VOLT CONTROL WIRING |
| CONTROL WIRING | |
MINIMUM 18 GA. WIRE |
|
| |
|
| FACTORY WIRING | |
(NEC CLASS 2) |
|
| |
|
| ||
|
|
| |
| FURNACE OR AIR HANDLER TERMINAL BLOCK |
CONTACTOR
TERMINALS
GND.
LUGCOIL
CONDENSING UNIT
C Y R G W
* TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.
*
Y R G W
ROOM THERMOSTAT
ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.
Unitary Products Group | 7 |