York GY9 warranty Filter Performance, Blower Performance CFM, Airflow with TOP Return

Page 4

036-21560-001 Rev. A (0204)

BLOWER PERFORMANCE CFM

AIRFLOW WITH TOP RETURN

MODELS

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE, INCHES W.C. (kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input/

Speed

0.1 (0.025)

0.2 (0.050)

0.3 (0.075)

0.4 (0.099)

0.5 (0.124)

0.6 (0.149)

0.7 (0.174)

0.8 (0.199)

0.9 (0.224)

1.0 (0.249)

Output/

Tap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow/

 

CFM

m3/min

CFM

m3/min

CFM

m3/min

CFM

m3/min

CFM

m3/min

CFM

m3/min

CFM

m3/min

CFM

m3/min

CFM

m3/min

CFM

m3/min

cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

1687

48

1652

47

1631

46

1595

45

1557

44

1511

43

1456

41

1382

39

1313

37

1211

34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60/55/

Medium High

1193

34

1183

33

1173

33

1162

33

1142

32

1115

32

1076

30

1036

29

982

28

950

27

1200/B

Medium Low

933

26

933

26

921

26

911

26

902

26

872

25

825

23

793

22

771

22

712

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

752

21

745

21

731

21

718

20

698

20

652

18

602

17

580

16

536

15

496

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

1686

48

1658

47

1623

46

1572

44

1534

43

1465

41

1391

39

1305

37

1202

34

1091

31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80/75/

Medium High

1257

36

1223

35

1218

34

1203

34

1177

33

1142

32

1094

31

1026

29

939

27

874

25

1200/B

Medium Low

977

28

982

28

976

28

955

27

934

26

899

25

843

24

791

22

738

21

686

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

775

22

777

22

757

21

733

21

698

20

663

19

627

18

584

17

549

16

490

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

2071

59

2026

57

1981

56

1935

55

1864

53

1796

51

1713

48

1625

46

1532

43

1401

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80/75/

Medium High

1583

45

1590

45

1569

44

1554

44

1532

43

1502

43

1457

41

1409

40

1327

38

1221

35

1600/C

Medium Low

1256

36

1275

36

1275

36

1288

36

1275

36

1265

36

1232

35

1187

34

1126

32

1023

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

937

27

939

27

936

26

945

27

942

27

936

26

912

26

874

25

810

23

726

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

1996

56

1961

56

1938

55

1896

54

1836

52

1779

50

1707

48

1625

46

1531

43

1399

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100/95/

Medium High

1449

41

1480

42

1495

42

1488

42

1488

42

1449

41

1417

40

1368

39

1299

37

1208

34

1600/C

Medium Low

1167

33

1192

34

1192

34

1187

34

1202

34

1192

34

1182

33

1140

32

1097

31

1018

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

932

26

900

25

871

25

840

24

805

23

761

22

710

20

663

19

641

18

623

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

2404

68

2320

66

2225

63

2138

61

2034

58

1924

54

1816

51

1692

48

1559

44

1422

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100/95/

Medium High

2018

57

1955

55

1883

53

1815

51

1750

50

1670

47

1586

45

1497

42

1394

39

1246

35

2000/C

Medium Low

1626

46

1581

45

1531

43

1488

42

1418

40

1363

39

1291

37

1225

35

1123

32

964

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

1336

38

1291

37

1249

35

1205

34

1155

33

1091

31

1018

29

951

27

884

25

759

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

2520

71

2432

69

2353

67

2251

64

2152

61

2042

58

1947

55

1815

51

1701

48

1525

43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120/112/

Medium High

2018

57

1979

56

1945

55

1911

54

1863

53

1779

50

1705

48

1599

45

1493

42

1353

38

2000/D

Medium Low

1586

45

1545

44

1501

42

1457

41

1407

40

1351

38

1287

36

1216

34

1081

31

926

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

1321

37

1266

36

1213

34

1163

33

1111

31

1071

30

987

28

864

24

763

22

700

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m3/min).

2.Motor voltage at 115 V.

FILTER PERFORMANCE

The airflow capacity data published in the “Blower Perfor- mance” table listed above represents blower performance WITHOUT filters. To determine the approximate blower per- formance of the system, apply the filter drop value for the fil- ter being used or select an appropriate value from the “Filter Performance” table shown.

NOTE: The filter pressure drop values in the “Filter Perfor- mance” table shown are typical values for the type of filter listed and should only be used as a guideline. Actual pres- sure drop ratings for each filter type vary between filter manu- facturer.

FILTER PERFORMANCE - PRESSURE DROP INCHES W.C. AND (KPA)

 

 

MINIMUM

 

 

FILTER TYPE

 

 

AIRFLOW RANGE

 

 

 

 

 

 

 

 

COARSE FIBER

 

 

OPENING SIZE

DISPOSABLE

PLEATED

 

 

WASHABLE**

 

 

 

 

 

 

 

 

CFM

m3/m

in2

cm2

In W.C.

kPA

In W.C.

kPA

In W.C..

kPA

0 - 750

0 - 21.4

230

584.2

0.01

0.00249

0.01

0.00249

0.15

0.03736

 

 

 

 

 

 

 

 

 

 

751 - 1000

21.25 - 28.32

330

838.2

0.05

0.01245

0.05

0.01245

0.20

0.04982

 

 

 

 

 

 

 

 

 

 

1001 - 1250

28.33 - 35.40

330

838.2

0.10

0.02491

0.10

0.02491

0.20

0.04982

 

 

 

 

 

 

 

 

 

 

1251 - 1500

35.41 - 42.48

330

838.2

0.10

0.02491

0.10

0.02491

0.25

0.06227

 

 

 

 

 

 

 

 

 

 

1501 - 1750

42.49 - 49.55

380

965.2

0.15

0.03736

0.14

0.03487

0.30

0.07473

 

 

 

 

 

 

 

 

 

 

1751 - 2000

49.56 - 56.63

380

965.2

0.19

0.04733

0.18

0.04484

0.30

0.07473

 

 

 

 

 

 

 

 

 

 

2001 & Above

56.64 - Above

463

1176.0

0.19

0.04733

0.18

0.04484

0.30

0.07473

 

 

 

 

 

 

 

 

 

 

*. Coarse Fiber Filters are the type supplied with furnace (if supplied).

4

Unitary Products Group

Image 4
Contents Warranty FeaturesDescription Natural GASInput/Output Size Combustion AIR Supply and Vent PipingMaximum Elbows and Vent Lengths Field Wiring Diagrams Power WiringHigh Altitude Pressure Switch Application Electrical and Performance DataFilter Performance Blower Performance CFMFilter Performance Pressure Drop Inches W.C. and KPA Airflow with TOP ReturnAccessories Applying Filter Pressure Drop to Determine System AirflowField Installed Accessories Electrical Model no Description 2ET03700324036-21560-001 Rev. a Unitary Products Group Unitary 5005 Norman Products York Group Drive 73069
Related manuals
Manual 12 pages 11.21 Kb

GY9 specifications

York GY9, GF9, and GM9 are advanced air conditioning units known for their efficiency and innovative technology. Designed primarily for commercial and industrial applications, these units are engineered to provide optimal performance while minimizing energy consumption.

One of the main features of the York GY9 series is its scroll compressor technology. This design is renowned for its reliability and quiet operation. The scroll compressors operate in a manner that reduces vibration and noise, making them suitable for environments where minimal disruption is crucial. Furthermore, these compressors are designed to optimize refrigerant circulation, contributing to improved cooling efficiency.

The GF9 model, on the other hand, is characterized by its modular design, which allows for easy scalability. This feature is particularly beneficial for businesses looking to expand their cooling capacity without extensive renovations. The modular approach means that multiple units can be connected and controlled as a single system, providing flexibility in design and installation.

In terms of energy efficiency, all three models integrate the latest environmentally-friendly refrigerants. These refrigerants help reduce the overall carbon footprint of the HVAC system while maintaining effective cooling performance. The units are designed to meet or exceed industry standards for energy efficiency, making them a cost-effective choice for long-term use.

Another notable characteristic of the York GY9, GF9, and GM9 units is their user-friendly control systems. Advanced control options include smart thermostats and building management system integration, allowing users to monitor and fine-tune their cooling performance remotely. This level of control enhances convenience and can lead to further energy savings through optimized operation.

Durability is also a key feature of these models. Constructed with robust materials, the York GY9, GF9, and GM9 are designed to withstand various environmental conditions, ensuring longevity and reducing maintenance costs. Their designs also incorporate advanced filtration systems, which improve indoor air quality by effectively removing pollutants and allergens.

In summary, York GY9, GF9, and GM9 air conditioning units stand out due to their efficient cooling, innovative technologies, energy-saving features, and robust construction. These units are ideal for commercial settings looking to balance performance with sustainability, all while ensuring a comfortable environment.