York E*FH060, E*FH018 warranty E4FH036S06, F2RP/F2FP036

Page 13

 

 

 

 

 

 

 

 

 

 

036-21031-004 Rev. A (0603)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING PERFORMANCE DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR CONDITIONER MODEL NO.

E4FH036S06

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

 

F2RP/F2FP036

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

1150

 

 

1250

 

 

1350

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING AIR

ID DB (°F)

85

80

 

75

70

85

80

75

70

85

80

75

70

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

72

67

 

62

57

72

67

62

57

72

67

62

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

40.5

37.4

 

34.3

31.6

40.8

37.7

34.7

31.9

41.0

37.9

35.0

32.1

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

25.6

25.7

 

26.0

26.3

26.5

26.8

27.1

27.2

27.5

27.6

28.2

28.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

2.65

2.63

 

2.63

2.60

2.69

2.67

2.66

2.64

2.78

2.77

2.74

2.74

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

38.8

35.8

 

32.8

30.2

39.1

36.1

33.2

30.5

39.3

36.3

33.5

30.8

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

25.0

25.0

 

25.4

25.6

25.9

26.0

26.5

26.6

26.9

27.0

27.4

27.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

2.86

2.86

 

2.84

2.83

2.90

2.89

2.87

2.86

3.00

2.98

2.96

2.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

37.2

34.3

 

31.6

28.9

37.5

34.6

31.9

29.2

37.6

34.9

32.1

29.6

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

24.3

24.6

 

25.0

24.9

25.5

25.6

26.0

25.9

26.3

26.7

26.9

26.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

3.27

3.23

 

3.21

3.21

3.28

3.26

3.25

3.24

3.39

3.36

3.34

3.34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

35.5

32.7

 

30.1

27.6

35.7

33.0

30.3

27.9

35.9

33.2

30.5

28.2

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

23.8

23.9

 

24.2

24.3

24.9

25.0

25.2

25.3

25.9

25.9

26.1

26.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

3.74

3.71

 

3.69

3.67

3.75

3.73

3.72

3.70

3.84

3.84

3.82

3.80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

33.8

31.1

 

28.6

26.3

34.0

31.4

28.9

26.6

34.2

31.6

29.0

27.1

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

23.2

23.3

 

23.6

23.9

24.3

24.3

24.5

24.5

25.3

25.3

25.5

25.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

4.30

4.28

 

4.25

4.21

4.31

4.31

4.29

4.26

4.43

4.40

4.38

4.36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

32.1

29.5

 

27.1

25.0

32.3

29.8

27.5

25.3

32.5

30.0

27.5

26.0

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

22.6

22.7

 

23.0

23.5

23.7

23.6

23.8

23.7

24.7

24.7

24.9

25.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W

4.86

4.85

 

4.81

4.75

4.87

4.89

4.86

4.82

5.02

4.96

4.94

4.92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

 

 

 

 

 

N1AHB12

G2FD036(S,H)17

1.00

1.00

1.01

 

 

 

 

 

N1VSB12

G2FD036(S,H)17

1.01

1.01

0.96

 

 

 

 

 

F2RP042

 

1.00

1.00

1.01

 

 

 

 

 

 

G1UA048S21

1.02

1.02

1.02

 

 

 

 

 

 

G1UA048S17

1.01

1.01

1.01

 

 

 

 

 

 

G2FD42(S,H)21

1.01

1.01

1.01

 

 

 

 

 

 

G2FD046(S,H)17

1.01

1.01

1.01

 

 

 

 

 

 

G2FD036(S,H)21

1.00

1.00

1.01

 

 

 

 

 

 

G2FD036(S,H)17

1.00

1.00

1.01

 

 

 

 

 

 

G1FA048S21

1.02

1.02

1.02

 

 

 

 

 

 

G1FA048S17

1.01

1.01

1.01

 

 

 

 

 

Unitary Products Group

13

Image 13
Contents Features WarrantyDescription Model Physical and Electrical DataFootnotes ProceduresSens Cooling Capacity With Air Handler CoilsSens TXV Unit COIL1 ARI HEATING2 Outdoor TEMP3 Heating Performance Air Handler and Multi-position CoilsFH with Variable Speed & Standard Furnace Coils Heating Performance Furnace CoilsSound Blanket AccessoriesStart Assist Kit 2SA067 Typical Field Wiring AIR Handler / Electrical Heat Typical InstallationF2RP/F2FP024 E4FH018S06Air Handler Coil E4FH024S06 Cooling Performance DataF2RP/F2FP030 G2FD030S,H17 E4FH030S06F2RP/F2FP036 E4FH036S06F2RP/F2FP042 E4FH042S06F2FP048 E5FH048S06G2FD060S,H24 E4FH060S06Entering Heating Performance DataOutdoor Indoor UnitE4FH024S06 E4FH30S06 E4FH036S06 1200 1400 1000 F2FP060 G2FD048S,H21,24 G2FD060S,H24 Unitary Products Group F2FP060 F2FV060 G2FD061H24 Unitary 5005 Norman Product York Group Drive 73069 AIR Handlers for NON-FURNACE Applications

E*FH060, E*FH018 specifications

The York E*FH060 and E*FH018 are advanced air handling units designed to optimize indoor air quality and comfort while enhancing energy efficiency. These models cater to a variety of commercial and industrial applications, demonstrating York's commitment to innovative engineering and user-friendly features.

One of the standout features of the E*FH series is its high-efficiency fan technology. The units utilize variable speed direct drive fans that significantly reduce energy consumption compared to traditional belt-driven fans. This technology not only contributes to lower operational costs but also minimizes noise levels, making these units ideal for environments where quiet operation is essential.

The E*FH060 and E*FH018 employ advanced heat recovery systems, efficiently reclaiming energy from exhaust air to pre-condition incoming fresh air. This capability enhances overall system efficiency and reduces the demand on heating and cooling systems. By leveraging energy recovery, these units help maintain optimal indoor temperatures while lowering utility bills.

Another innovative aspect of the E*FH series is their modular design, which facilitates easy installation and maintenance. The units can be customized to meet specific requirements, allowing for configurations that adapt to varying space constraints. This versatility ensures that whether it's a small office building or a large industrial facility, the right solution is available.

In terms of controls, the York E*FH models feature state-of-the-art building management system (BMS) integration capabilities. This allows for seamless connectivity and monitoring, enabling users to optimize performance through real-time data analytics. The intuitive user interface enhances operability while providing crucial insights into the system's performance.

The E*FH060 and E*FH018 are also equipped with advanced filtration systems that ensure high indoor air quality. HEPA filters can be incorporated into the design, capturing airborne particles and allergens, thus fostering a healthier indoor environment. This focus on air quality aligns with growing concerns about health and wellness in built environments.

Furthermore, both units adhere to stringent environmental standards, ensuring that they not only comply with regulations but also support sustainable practices. The integration of eco-friendly refrigerants and efficient energy use makes these models a responsible choice for organizations looking to reduce their carbon footprint.

In conclusion, the York E*FH060 and E*FH018 air handling units stand out due to their efficiency, innovative technology, and adaptability. These features make them an excellent investment for any facility aiming to enhance comfort, ensure air quality, and achieve sustainability goals while managing energy costs effectively.