York H*RE024 warranty Tdr

Page 4

036-21315-001 Rev. A (0502)

COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils

 

FURNACE**

COIL

 

 

 

COOLING

 

 

UNIT MODEL

CFM RANGE

W

MODEL

RATED

NET MBH

SEER + TXV

SEER + TXV1

EER

 

(MIN.-MAX.)

CFM

 

 

W/O TDR

 

 

TOTAL

SENS.

+ TDR*

 

 

 

 

 

 

14

G1FA036S14

800

25.0

18.0

13.85

-

12.30

 

 

17,21

G1FA036S17,21

800

24.8

17.9

13.85

-

12.20

 

 

-

G1HD036

800

25.0

18.1

14.00

-

12.35

 

 

17

G1NA036S17L

800

24.0

16.6

13.50

-

12.00

 

700

21

G1NA048S21D

800

24.0

16.6

13.50

-

12.00

H1RE024S06

14

G1UA036S14

800

25.0

18.0

13.85

-

12.30

900

17,21

G1UA036S17,21

800

24.8

17.9

13.85

-

12.20

 

 

 

17

G2FD030S17

800

24.8

17.9

13.85

-

12.20

 

 

14

G2FD035S14

800

24.8

17.9

13.85

-

12.20

 

 

17

G2FD036S17

800

25.2

18.1

14.00

-

12.35

 

 

21

G2FD036S21

800

25.2

18.1

14.00

-

12.45

 

 

14

G1FA036S14

1000

28.4

20.0

13.00

-

11.75

 

 

17,21

G1FA036S17,21

1000

28.4

20.0

13.00

-

11.65

 

 

21,24

G1FA048S21,24

1000

30.0

21.8

14.00

-

12.40

 

 

-

G1HD048

1000

30.0

21.5

14.00

-

12.40

 

 

17

G1NA036S17L

1000

29.0

20.0

-

13.50

11.95

 

 

24

G1NA042S24W

1000

29.0

20.7

-

14.00

12.00

 

875

21

G1NA048S21D

1000

29.0

20.0

-

13.50

11.95

H1RE030S06

14

G1UA036S14

1000

28.4

20.0

13.00

-

11.75

1125

 

17,21

G1UA036S17,21

1000

28.4

20.0

13.00

-

11.65

 

 

 

 

21,24

G1UA048S21,24

1000

30.0

21.8

14.00

-

12.40

 

 

17

G2FD030S17

1000

28.4

20.4

13.00

-

11.65

 

 

17

G2FD036S17

1000

28.8

20.7

13.10

-

11.80

 

 

21

G2FD036S21

1000

28.8

21.0

13.10

-

12.10

 

 

21,24

G2FD048S21,24

1000

30.2

21.8

-

14.00

12.50

 

 

21,24

G1FA048S21,24

1200

35.2

25.3

14.00

-

12.30

 

 

-

G1HD048

1200

34.8

25.0

13.75

-

12.30

 

 

17

G1NA036S17L

1200

33.0

23.4

-

13.00

11.30

 

 

24

G1NA042S24W

1200

34.6

25.0

-

14.00

12.00

 

1050

21

G1NA048S21D

1200

33.0

23.4

-

13.00

11.30

H1RE036S06

21,24

G1UA048S21,24

1200

35.2

25.3

14.00

-

12.30

1350

17

G2FD036S17

1200

34.0

24.5

13.35

-

11.80

 

 

 

21

G2FD036S21

1200

34.0

24.8

13.35

-

12.05

 

 

21

G2FD042S21

1200

34.8

25.4

13.70

-

12.10

 

 

17

G2FD046S17

1200

35.0

25.6

14.00

-

12.20

 

 

21,24

G2FD048S21,24

1200

35.2

25.7

14.00

-

12.45

 

 

21,24

G1FA048S21,24

1400

39.0

28.4

-

13.50

11.45

 

 

21,24

G1FA060S21,24

1400

40.5

29.6

-

14.00

11.80

 

 

-

G1HD048

1400

39.0

28.4

-

13.25

11.50

 

 

24

G1NA042S24W

1400

40.5

29.5

-

14.00

11.75

 

1225

21

G1NA048S21D

1400

39.0

27.3

-

13.00

11.50

H2RE042S06

21,24

G1UA048S21,24

1400

39.0

28.4

-

13.50

11.45

1575

21,24

G1UA060S21,24

1400

40.5

29.6

-

14.00

11.80

 

 

 

21

G2FD042S21

1400

39.0

28.2

-

13.25

11.35

 

 

17

G2FD046S17

1400

39.0

28.6

-

13.50

11.45

 

 

21,24

G2FD048S21,24

1400

39.5

28.9

-

13.50

11.60

 

 

24

G2FD060S24

1400

40.5

29.6

-

14.00

11.80

 

 

21,24

G1FA048S21,24

1600

45.0

32.6

-

13.40

11.50

 

 

21,24

G1FA060S21,24

1600

46.5

33.9

-

13.85

11.80

 

 

-

G1HD048

1600

45.0

32.4

-

13.25

11.45

 

 

24

G1NA042S24W

1500

46.5

32.8

-

14.00

11.85

 

1400

21

G1NA048S21D

1400

44.0

29.0

-

13.00

11.50

H2RE048S06

21,24

G1UA048S21,24

1600

45.0

32.6

-

13.40

11.50

1800

 

21,24

G1UA060S21,24

1600

46.5

33.9

-

13.85

11.80

 

 

 

 

21,24

G2FD048S21,24

1600

45.5

33.2

-

13.50

11.60

 

 

24

G2FD060S24

1600

46.5

33.9

-

13.85

11.80

 

 

24

G2FD061H24

1600

47.0

34.3

-

14.00

11.90

For Notes See

Page 5.

 

 

 

 

 

 

 

 

4

Unitary Products Group

Image 4
Contents Features WarrantyDescription Connection Unit DimensionsModel Inches Line Size Cooling Capacity With Air Handler Coils TDR Cooling Capacity With Variable Speed Furnaces Cooling Performance AccessoriesSound Ratings Typical Installation Typical Field WiringCooling Performance Data H1RE024S06F2RP/F2FP036 Air Handler CoilH1RE030S06 G1UA048S21H1RE036S06 H2RE042S06 G1UA060S21,24H2RE048S06 G2FD060S24, G1UA060S21,24H2RE060S06 G2FD060S24 G1UA060S21AIR Handlers for NON-FURNACE Applications 036-21315-001 Rev. a Unitary 5005 Norman Product York Group Drive 73069

H*RE024 specifications

York H*RE024 is a cutting-edge heating and cooling unit that has made significant strides in energy efficiency and performance. Designed for commercial and industrial applications, this HVAC system is built to provide reliable climate control while minimizing energy consumption.

One of the main features of the York H*RE024 is its advanced inverter technology. This technology allows the unit to adjust its speed based on the current demand for heating or cooling, leading to substantial energy savings. By operating at lower speeds during mild weather conditions, the system avoids the energy spikes associated with conventional HVAC units that operate on a fixed speed. This results in a smoother, quieter operation while also extending the lifespan of the unit.

Another key characteristic of the York H*RE024 is its enhanced heat exchanger design. The unit incorporates a more efficient heat transfer process, which improves overall performance and reduces operational costs. The heat exchangers are crafted from high-quality materials that ensure durability and resistance to corrosion, making them ideal for long-term use in various environments.

The H*RE024 is also equipped with smart technology features, including Wi-Fi connectivity and integration with building management systems. This allows users to monitor and control the HVAC system remotely through mobile apps or web interfaces. Such features enhance user convenience and enable proactive maintenance, leading to fewer unexpected breakdowns.

In terms of environmental impact, the York H*RE024 utilizes refrigerants that comply with the latest global standards, reducing ozone depletion potential. Additionally, its high seasonal energy efficiency ratio (SEER) rating underscores its commitment to reducing carbon footprints in the commercial sector.

Noise reduction is another vital aspect of the York H*RE024. The unit is designed with sound-dampening materials and features that minimize operational noise, making it suitable for sound-sensitive locations such as schools, hospitals, and office buildings.

In conclusion, the York H*RE024 stands out as a versatile, energy-efficient HVAC solution tailored for commercial and industrial use. With its advanced technologies, smart features, and commitment to sustainability, this unit provides not only exceptional performance but also peace of mind for those seeking reliable climate control. Its design ensures that it meets modern demands for efficiency while simultaneously delivering comfort and reliability.