York H*BE-F018 warranty AHP/SHP48 AHP/SHP60 AV/SV48 AV/SV60

Page 15

332018-BTG-D-0208

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

HBBE-F048S

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

 

FC/MC/PC/UC60

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

1400

 

 

1600

 

 

1800

 

ENTERING AIR

ID DB

85

80

70

85

80

70

85

80

70

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

ID WB

72

67

57

72

67

57

72

67

57

 

T.C.

53.3

49.5

45.5

54.3

50.2

46.4

55.2

51.0

47.3

75

 

 

 

 

 

 

 

 

 

 

S.C.

33.4

32.6

31.1

35.9

35.0

33.0

38.3

37.4

34.9

 

K.W

2.76

2.72

2.69

2.77

2.74

2.70

2.77

2.76

2.70

 

T.C.

51.2

47.7

43.9

52.0

48.4

44.8

52.8

49.1

45.7

85

 

 

 

 

 

 

 

 

 

 

S.C.

33.1

32.1

30.6

35.4

34.5

32.6

37.7

36.8

34.6

 

K.W

3.07

3.04

3.01

3.07

3.05

3.02

3.08

3.06

3.03

 

T.C.

49.0

45.9

42.4

49.7

46.5

43.2

50.3

47.2

44.1

95

 

 

 

 

 

 

 

 

 

 

S.C.

32.7

31.6

30.0

34.9

33.9

32.2

37.1

36.2

34.4

 

K.W

3.37

3.35

3.33

3.38

3.36

3.34

3.38

3.37

3.35

 

T.C.

46.6

43.5

40.1

47.3

44.1

40.8

48.0

44.7

41.6

105

 

 

 

 

 

 

 

 

 

 

S.C.

31.7

30.7

29.0

34.0

32.9

31.2

36.3

35.1

33.3

 

K.W

3.78

3.75

3.74

3.79

3.76

3.75

3.79

3.77

3.75

 

T.C.

44.1

41.1

37.8

44.9

41.6

38.4

45.6

42.2

39.1

115

 

 

 

 

 

 

 

 

 

 

S.C.

30.8

29.8

28.1

33.1

31.9

30.2

35.4

34.1

32.3

 

K.W

4.18

4.16

4.15

4.19

4.16

4.15

4.21

4.16

4.15

 

T.C.

41.7

38.7

35.5

42.5

39.2

36.0

43.3

39.7

36.6

125

 

 

 

 

 

 

 

 

 

 

S.C.

29.8

28.8

27.1

32.2

31.0

29.2

34.6

33.1

31.3

 

K.W

4.59

4.56

4.56

4.60

4.56

4.55

4.62

4.56

4.55

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

AHP/SHP48

1.00

0.99

1.07

AHP/SHP60

1.00

0.99

1.03

AV/SV48

1.02

1.03

0.91

AV/SV60

1.02

1.03

0.91

F*FV060

1.02

1.03

0.91

MA16C

FC/MC48C

0.97

0.98

1.04

MA16C

FC60C

1.00

1.00

1.07

MA20D

FC/MC48D

0.97

0.98

1.04

MA20D

FC/MC60D

1.00

1.00

1.07

MA20D

MC61D

1.01

1.01

1.04

MA20D

FC/MC62D

1.01

1.01

1.04

MV20D

FC/MC48D

0.99

0.98

1.02

MV20D

FC/MC60D

1.01

1.00

1.04

FC/MC/PC/UC48

0.97

0.98

1.04

HC48

0.97

0.96

1.04

HC60

0.99

1.00

1.06

HD48

0.97

0.96

1.04

HD60

0.99

1.00

1.06

MC61

1.01

1.01

1.04

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

(F,L)L8V*C20

FC/PC60C

1.00

1.00

1.03

(F,L)L8V*C20

MC60D

1.00

1.00

1.03

(F,L)L8V*C20

MC61D

1.01

1.01

1.04

(F,L)L8V*C20

FC/MC62D

1.01

1.01

1.04

FL9(C,V)*C20

FC/PC60C

1.00

1.00

1.03

FL9(C,V)*C20

MC60D

1.00

1.00

1.03

FL9(C,V)*C20

MC61D

1.01

1.01

1.04

FL9(C,V)*C20

FC/MC62D

1.01

1.01

1.04

FL9(C,V)*D20

FC/MC/PC60D

1.00

1.00

1.03

FL9(C,V)*D20

MC61D

1.01

1.01

1.04

FL9(C,V)*D20

FC/MC62D

1.01

1.01

1.04

Unitary Products Group

15

Image 15
Contents Technical Guide Physical and Electrical Data Unitary Products Group Footnotes Cooling Capacity With Air Handler Coils Furnace Cooling Capacity With Variable Speed Furnaces Variable Speed Sound Power Ratings Cooling Performance Data MA12B FC/MC35B MV12B FC/MC/PC/UC32B MA12B FC/MC36B MV12B MV16C FC/MC36C 1000 1200 1400 1300 1450 1550 AHP/SHP48 AHP/SHP60 AV/SV48 AV/SV60 AIR Conditioner Model no HCBE-F060S Indoor Coil Model no

H*BE-F018 specifications

The York H*BE-F018 is a highly advanced air conditioning and heating solution designed to provide exceptional indoor climate control for both residential and commercial spaces. One of its main features is the inverter technology that allows for variable speed operation. This technology enables the unit to adjust its cooling or heating output according to the specific needs of the environment, resulting in significant energy savings and enhanced comfort levels.

In addition to being energy efficient, the H*BE-F018 is designed for quiet operation. Its advanced fan and compressor technology minimizes noise, making it an ideal choice for areas where noise reduction is essential, such as bedrooms, offices, and libraries. The unit also features a sleek and modern design that can seamlessly blend into various architectural styles, enhancing the aesthetic appeal of any space.

The York H*BE-F018 is equipped with advanced filtration systems that improve indoor air quality. These filters capture dust, allergens, and other pollutants, ensuring that the air circulated within the environment is clean and healthy. This feature is particularly beneficial for individuals with allergies or respiratory issues.

Another key characteristic of the H*BE-F018 is its smart connectivity options. The unit can be controlled remotely through a smartphone app, allowing users to monitor and adjust temperature settings from anywhere. This connectivity extends to compatibility with smart home systems, enabling integrated climate control that enhances overall energy efficiency.

The installation process for the York H*BE-F018 is user-friendly, with a compact design that requires minimal space. Service and maintenance have also been simplified, with easy access to critical components ensuring that technicians can perform routine checks quickly and efficiently.

Durability is a hallmark of the York H*BE-F018. Constructed with high-quality materials and designed to withstand the rigors of varying environmental conditions, this unit promises long service life and reliability.

In summary, the York H*BE-F018 combines energy efficiency, advanced technology, and user-friendly features to deliver superior comfort and air quality. Its inverter technology, quiet operation, smart connectivity, and robust construction make it an outstanding choice for anyone seeking a reliable heating and cooling solution for their space.