York K3EU120, K2EU060, K4EU090, K3EU180 manual Unit Clearances KEU090, 090-120

Page 17

036-21300-002-A-0905

 

 

 



 

 





 

 

 

+./#+/54

 

 

 

2EMOVED ONLY WHEN

 

 

!)2

%LECTRIC (EATA!CCESSORY

 

 

/54

 

 



IS USED

 

 

 

 

 

 



 



 

 

 







!)2

).





 +./#+/54 &/2/0/7%277)2).' "ACKA0ANEL

$O NOTOREMOVE THIS KNOCKOUTCWHEN THE UNIT IS EQUIPPEDPWITH AN %LECTRIC (EAT !CCESSORYS2EFERYTO DETAIL OF THEE(EATER !CCESSORY FOR POWER WIRING ACCESS OPENING

 (/,% 7"53().' &/2/#/.42/, 7)2).' "ACKC0ANEL

 

 

 

 

 

 



 

 



 

",/7%2 -/4/2

 

!.$.$2)6%%

 

!##%33 0!.%,

 

4HISSSIDE ONLY

 

(/,% 7)4( '2/-

 

-%44&/2//$

 

,)15)$ ,).%

 

 





 

 

 

 

(/,% 7)4( '2/-

 

 

-%44&/2//$

 

 35#4)/. ,).%



 





 



 



/$ $2!).

 

 

 

 

#/..-USTSBE



 

TRAPPED

&),4%2 !##%33 0!.%,

7HENEUNIT IS INSTALLED IN

AAHORIZONTAL POSITION DO NOTOBLOCK THIS AREARWITH REFRIGERANTAPIPING

All dimensions are in inches. They are subject to change without notice. Certi- fied dimensions will be provided upon request.

FIGURE 2 - UNIT DIMENSIONS KEU090 & 120

ACCESSORIES

ELECTRIC HEATER - Add 14-1/4” to unit height when used.

SUPPLY AIR PLENUM - Add 27-1/2” to unit height when used.

BASE - Add 20” to unit height when used.

TABLE 19: UNIT CLEARANCES KEU090 & 120

MINIMUM CLEARANCES

090-120

 

 

Side with RETURN AIR opening

24”

 

 

Side with SUPPLY AIR opening1

24”

Side with PIPING CONNECTIONS2

36”

Side opposite with PIPING CONNECTIONS

12”

 

 

Side with access for both POWER & CONTROL

-

WIRING3,

 

Bottom4

-

1.Overall dimensions of the unit will vary if an electric heater, a supply air plenum or a base is used.

2.This dimension is required for removal of the coil. Only 26” is required for normal service.

3.Although no clearance is required for service and oper- ation, some clearance may be required for routing the power and control wiring.

4.Allow enough clearance to trap the condensate drain line.

Unitary Products Group

17

Image 17
Contents Supply AIR Plenums THREE-PHASE Electric HeatersReturn AIR Grills BasesTable of Contents Steam Coils HOT Water CoilsSuspension KIT ThermostatsVertical and Horizontal Model 15 TONAccessories KEU Operating Weights LBSModel Basic UnitWatts Unit CFM Octave Band Centerline Frequency HZ Model ESP BlowerIWG BHPHeating Capacity Electric Heat Accessory HOT Water CAPACITY1, MBH Steam Coil CAPACITY1, MBH@2 PSIG2Pressure Drop VS. GPM Capacity Correction VS. GPMExternal Static Pressure CFM RPM BHP Supply AIR Blower Performance KEU060 5 TONExternal Static Pressure CFM Supply AIR Blower Performance KEU090 7.5 TONBHP RPM Supply AIR Blower Performance KEU120 10 TONSupply AIR Blower Performance KEU180 15 TON Electric Heat KW Supply Air Return Hot Water Steam Static Resistance for Unit Accessories IWG KEU060-120Static Resistance for Unit Accessories IWG KEU180 Blower Motor and Drive Data Supply AIR Plenum Performance DataKEU Physical Data Bottom4 Unit Clearances KEU060090-120 Unit Clearances KEU090Unit Clearances KEU180 Unit Dimensions KEU180 AccessoriesSqueeze connector in both of the 7/8 openings Accessory DimensionsHeater Nom Unit Heater Dimensions inches Model Electric Heater Dimensions KEU060, 090, 1202HT045010251 2HT045016251 060 22-1/4 19-1/4Steam Coil KEU Electrical Data Power Indoor Heater Nominal Min Max. Fuse1Hacr Tons180 Cooling only Unit Field Wiring for Power SupplyField Wiring for Units with Electric Heat 036-21300-002-A-0905 036-21300-002-A-0905 Supersedes 036-21300-001-A-0901

K3EU180, K4EU090, K3EU120, K2EU060 specifications

The York K3EU120, K2EU060, K3EU180, and K4EU090 are part of York's innovative lineup of HVAC systems, designed for energy efficiency, reliability, and cutting-edge technology. These models cater to various residential and commercial applications, providing optimal climate control while minimizing energy consumption.

The York K3EU120 is designed for medium to large commercial spaces. One of its main features is the advanced inverter-driven compressor technology, which allows for variable speed operation. This ensures that the system only consumes energy as needed, adapting to the specific heating and cooling demands. Additionally, it boasts a high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings, making it an excellent choice for reducing overall operational costs.

The K2EU060 is engineered for smaller commercial applications, such as offices and retail spaces. This model includes a compact design, making it easy to install in tight spaces. It features a low noise operation, promoting a comfortable environment without disrupting business activities. The unit also includes smart controls that allow for remote monitoring and adjustments, enhancing user convenience and energy management.

The K3EU180 model is a heavy-duty unit designed for larger facilities that require robust performance. It is equipped with advanced refrigerant management systems, ensuring optimal cooling efficiency and compliance with environmental regulations. The unit also integrates seamlessly with building management systems (BMS), allowing operators to manage multiple HVAC units from a single interface. This level of connectivity enhances operational efficiency and helps in predictive maintenance by monitoring system performance.

Lastly, the K4EU090 is versatile, making it suitable for various applications including light commercial and multi-family buildings. It highlights energy recovery options, which recycles waste heat to provide additional heating, improving the overall efficiency of the system. This model also features advanced filtration systems that enhance indoor air quality by reducing airborne particles, allergens, and pollutants.

Overall, each of these York models showcases a commitment to forward-thinking HVAC solutions that prioritize energy efficiency, ease of use, and environmental responsibility. Through advanced technologies and innovative features, the York K3EU120, K2EU060, K3EU180, and K4EU090 stand out in their class and offer long-term benefits for end-users.