HP 2309V, 2309M manual Tools Required

Page 2

refractory ceramic fibers

Components, parts and materials containing radioactive substances

2.0 Tools Required

0

List the type and size of the tools that would typically be used to disassemble the product to a point where components and materials requiring selective treatment can be removed.

Tool Description

Description #1: Bushing Screwdriver

Description #2: Crossing Screwdriver

Description #3

Description #4

Description #5

3.0 Product Disassembly Process

Tool Size (if applicable)

(HEX5.5MM)

2#

3.1 List the basic steps that should typically be followed to remove components and materials requiring selective treatment:

1.Lay the monitor on the desk, remove the VESA mounting cover with hand.

2.Unlock the 4 screws which they fix the VESA mounting by 2# screwdriver.

3.Unlock the 4 screws which they fix the stand by 2# screwdriver.

4.Remove the front bezel with hand from product

5.Remove the backcover with hand from Product.

6.Seprate the Keypad and backcover with hand

7.Unlock the 2 screws which they fix the chassis and panel, and then pull the LVDS out .

8.Unlock 2 screws for DVI port, D-SUB port, Power port, and 7 screws which they fix between chassis and PCA boards, power board and IF board. Pull the wires out.

9.Unlock the 2 screws which they fix between the bottom-side and the base, and then unlock the 12 screws which they fix between the base and base-cover.

10.Remove the arm-rear and then unlock the 4 screws which they fix between the arm-front and the rion.

11.To see the detail process are as attached files including assemble panel.

3.2Optional Graphic. If the disassembly process is complex, insert a graphic illustration below to identify the items contained in the product that require selective treatment (with descriptions and arrows identifying locations).

EL-MF877-00

Page 2

Template Revision A

 

Image 2
Contents Product End-of-Life Disassembly Instructions Tools Required Disassembly Flowchart for HP 2309 Model Page Page Page Technical Notificationion Sequence of Module Disassembly for Lamp Separationration Sequence of Module Disassembly for Lamp Separationration Sequence of Module Disassembly for Lamp Separationration Method of lamp disassembly on LM230WF1-TLA3/TLB3 Dismantle the case topDown Method of lamp disassembly on LM230WF1-TLA3-731 Remove lamp wire tapes Final Lamp Assy