HP ML310 Generation 3 Server Cabling ML310 manual Internal Tape

Page 1

HP ProLiant ML310 Generation 3 Server Cabling Chart

This chart provides information on cables required for internal and external options.

The ML310 G3 Server includes a single SCSI or serial cable for system hard drive connections.

Use this chart to identify any additional cables that may be required.

 

Cables included with ProLiant ML310 G3 Server models:

 

SCSI model (point-to-point)

302377-001

Serial (SAS/SATA) model (point-to-point)

361316-009

 

Connector on the

Cable Type Included

 

 

Option

Option

with the Option

Supported HBAs/Controllers

Additional Cables Required

 

 

 

 

 

Internal Hot-Plug Hard Drives

 

 

 

 

 

 

 

 

 

See ProLiant ML310 G3 Server Cabling Requirements for Hard Drives for detailed, graphical description (p. 2)

Internal Tape

 

 

 

 

 

64-bit/133-MHz Single-Channel Ultra320 SCSI HBA G2 (P/N 374654-B21)

 

LVD wide 68-pin

HD68-HD68

64-bit/133-MHz Dual-Channel Ultra320 (P/N 268351-B21)

No additional cables required

 

 

64-bit/66-MHz Dual-Channel Wide Ultra 3 (P/N 284688-B21)

 

 

 

 

 

External Tape Drives and Autoloaders

 

 

 

 

 

Slot-based Ultra320 SCSI Controller (Standard in SCSI models)

Order the VHDCI internal-to-external kit (P/N 333370-B21)

 

 

 

LVD wide 68-pin

HD68-VHDCI

64-bit/133-MHz Single-Channel Ultra320 SCSI HBA G2 (P/N 374654-B21)

 

 

 

64-bit/133-MHz Dual-Channel Ultra320 (P/N 268351-B21)

No additional cables required

 

 

64-bit/66-MHz Dual-Channel Wide Ultra 3 (P/N 284688-B21)

 

 

 

 

 

External Tape Libraries and Optical Jukeboxes

 

 

 

Slot-based Ultra320 SCSI Controller (Standard in SCSI models)

VHDCI

No SCSI cable included

Order the VHDCI internal-to-external kit (P/N 333370-B21) and one of the following VHDCI-VHDCI cables: VHDCI-VHDCI cable. 6 ft (P/N 341174-B21) VHDCI-VHDCI cable. 12 ft (P/N 341175-B21)

64-bit/133-MHz Dual-Channel Ultra320 (P/N 268351-B21)

Order one of the following VHDCI-VHDCI cables:

64-bit/66-MHz Dual-Channel Wide Ultra3 (P/N 284688-B21)

VHDCI-VHDCI cable. 6 ft (P/N 341174-B21)

64-bit/133-MHz Single-Channel Ultra320 SCSI HBA G2 (P/N 374654-B21)

VHDCI-VHDCI cable. 12 ft (P/N 341175-B21)

 

 

NOTE: The information in this chart identifies standard and optional cables for purchase required for controller-to-option configuration. For information on how to cable an

 

option, refer to the HP ProLiant ML310 Generation 3 Server User Guide and the device-specific documentation. For information on the specific options supported by the

 

server, refer to the server and device QuickSpecs.

 

© 2002, 2005 Hewlett-Packard Development Company, L.P.

 

Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided "as is" without warranty of any kind and is subject to change without notice. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

PN: 411069-001

Date: November 4, 2005

Image 1
Contents Internal Tape HP ProLiant ML310 Generation 3 Server Cabling ChartExternal Tape Drives and Autoloaders External Tape Libraries and Optical JukeboxesFor Hot Plug Serial SAS/SATA Hard Drive RAID Configurations