York D2EB030 manual Table of Contents

Page 2

360101-XTG-B-0508

TABLE OF CONTENTS

DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 STANDARD FEATURES / BENEFITS . . . . . . . . . . . . . . . . .1 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . .3 TYPICAL APPLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . .16 MECHANICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . .21

LIST OF FIGURES

Fig. #

Pg. #

1 UNIT CUTAWAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 TYPICAL FIELD WIRING DIAGRAM . . . . . . . . . . . . . 11 3 UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 14 4 CENTER OF GRAVITY. . . . . . . . . . . . . . . . . . . . . . . . 15 5 TYPICAL SLAB ON GROUND INSTALLATION. . . . . 16 6 TYPICAL ROOF CURB INSTALLATION . . . . . . . . . . 16

7 ROOF CURB DIMENSIONS (8” ROOF CURB ALSO AVAILABLE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

8 ROOF CURB APPLICATION . . . . . . . . . . . . . . . . . . . 17

9 TYPICAL WIRING DIAGRAM (208/230-1-60 POWER SUPPLY) DEB MODELS . . . . . . . . . . . . . . . . . . . . . . . 18

10 TYPICAL WIRING DIAGRAM (208/230-3-60 POWER SUPPLY) DEB MODELS . . . . . . . . . . . . . . . . . . . . . . . 19

11 TYPICAL WIRING DIAGRAM (460-3-60 AND 575-3-60 POWER SUPPLY) DEB MODELS . . . . . . . . . . . . . . . . 20

LIST OF TABLES

Tbl. #

Pg. #

1 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 RATINGS - ARI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3 COOLING CAPACITIES - 2-1/2 TON (DEB030) . . . . . . 6 4 COOLING CAPACITIES - 3 TON (DEB036) . . . . . . . . . 7 5 COOLING CAPACITIES - 3-1/2 TON (DEB042) . . . . . . 8 6 COOLING CAPACITIES - 4 TON (DEB048) . . . . . . . . . 9 7 COOLING CAPACITIES - 5 TON (DEB060) . . . . . . . . 10

8 SIDE AND BOTTOM SUPPLY AIR BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

9 ADDITIONAL STATIC RESISTANCE . . . . . . . . . . . . . 11 10 ELECTRICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 11 ELECTRICAL DATA (COOLING/ELECTRIC HEAT) . . 12 12 UNIT WEIGHTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

PRODUCT CATEGORY

D = Single Package Air Conditioner (Air Cooled)

PRODUCT GENERATION

2 = 2nd Generation

PRODUCT IDENTIFIER

EB = 10 SEER Cooling Models

D 2 E B 0 2 4 A 0 6

NOMINAL COOLING

CAPACITY (MBH)

030 = 30,000 BTUH

036 = 36,000 BTUH

042 = 42,000 BTUH

048 = 48,000 BTUH

060 = 60,000 BTUH

VOLTAGE CODE

06 = 208/230-1-60

25 = 208/230-3-60

46 = 460-3-60

58 = 575-3-60

FACTORY

INSTALLED ELECTRIC HEAT

A = No Electric Heat Installed

2

Johnson Controls Unitary Products

Image 2
Contents Standard Features / Benefits 9.4 EER Export only DescriptionTable of Contents Standard FEATURES/BENEFITS FIELD-INSTALLED AccessoriesUnit Cutaway Physical Data Ratings ARICooling Capacities 2-1/2 TON DEB030 Outdoor CoilCooling Capacities 3 TON DEB036 Cooling Capacities 3-1/2 TON DEB042 Cooling Capacities 4 TON DEB048 Cooling Capacities 5 TON DEB060 Side and Bottom Supply AIR Blower Performance Additional Static ResistanceElectrical Data Electrical Data Cooling / Electric Heat042 208/230-3-60 11.5 88.0 2NH04501025 Unit Dimensions Unit Weights Center of GravityTypical Slab on Ground Installation Typical ApplicationsRoof Curb Application Typical Wiring Diagram 208/230-1-60 Power Supply DEB Models Typical Wiring Diagram Notes Typical Wiring Diagram Legend Typical Wiring Diagram 208/230-3-60 Power Supply DEB ModelsXTG-B-0508 Outdoor Condenser FAN Assembly Mechanical SpecificationsIndoor Evaporator FAN Assembly Unit CabinetElectrical Requirements Unit Operating CharacteristicsElectric Heating Section XTG-B-0508 Johnson Controls Unitary Products Johnson Controls Unitary Products York Drive Norman, OK

D2EB030 specifications

The York D2EB030 is a prominent model in the realm of commercial climate control systems, specifically designed to cater to medium to large-scale applications. This equipment stands out due to its high efficiency and reliability, ensuring optimal thermal comfort in various settings, from office buildings to warehouses.

One of the main features of the York D2EB030 is its capacity. With a nominal cooling capacity of around 30 tons, it is well-suited for substantial cooling demands. This makes it an excellent choice for facilities that require consistent and effective temperature management. Additionally, it offers variable refrigerant flow (VRF) operation, which allows for simultaneous heating and cooling in different zones, providing enhanced comfort and flexibility.

The D2EB030 is equipped with advanced inverter technology. This feature allows the compressor to modulate its speed based on the cooling or heating needs of the environment, leading to significant energy savings. By adjusting the refrigerant flow and maintaining more stable indoor temperatures, the inverter-driven compressor reduces operational costs and energy consumption compared to traditional systems.

Additionally, the unit boasts a range of control options. It can be integrated with smart building management systems, allowing for remote monitoring and control through mobile devices or computers. This connectivity enables facility managers to optimize operation schedules, perform maintenance checks, and respond quickly to any issues, enhancing overall efficiency.

In terms of build quality, the York D2EB030 showcases robust construction, designed to withstand the rigors of commercial use. Its corrosion-resistant materials ensure longevity and reduce maintenance requirements. The system is also designed with sound-dampening features, resulting in quieter operation—a crucial aspect in noise-sensitive environments.

Among its environmental considerations, the unit utilizes refrigerants that are compliant with global regulations, contributing to lower greenhouse gas emissions. Moreover, its design promotes higher energy efficiency ratios (EER) and seasonal energy efficiency ratios (SEER), which are critical for reducing the overall carbon footprint.

In summary, the York D2EB030 stands out in the market for its combination of robust features, advanced technologies, and energy efficiency, making it a top choice for commercial climate control solutions. With its capacity, smart technology integration, and environmental considerations, this model is tailored to meet the dynamic needs of modern facilities while ensuring cost-effectiveness and sustainability.