HP Clemco 60, Clemco O.M. 10533 manual Window Frame, Chin Strap, Filter Kit, Replacement Parts

Page 13

APOLLO 60 HP SUPPLIED-AIR RESPIRATOR

Page 12

 

 

 

 

9.4.2Separate the Velcro tabs on the back of the cape. See Figure 5.

Air Inlet

Fitting

Notch

Cape Removal

Velcro Tab

Figure 5.

9.4.3Slide the ends of the cape to the notch. Continue sliding one end of the cape out of the groove until the entire cape is detached from the helmet.

9.4.4To install the cape, separate the Velcro tabs on the cape and slide one end into the groove on the bottom edge of the cape attachment strap at the point where the groove is notched. Continue sliding the cape around the bottom of the helmet until the entire cape is completely into the groove. NOTE! Spraying a non-toxic silicone-base lubri- cant into the groove will reduce friction and ease assem- bly.

9.4.5Join the Velcro tabs at the notch.

9.5Inner Collar

9.5.1The inner collar is a very important factor in controlling air escape from the helmet and preventing ingress of dust.

9.5.2The elastic properties of the collar are intended to provide a snug fit on the user’s neck. The inner collar must be replaced before it is stretched to the point where it no longer fits snug against the neck. The collar unzips from the outer cape for replacement or washing. See Section 8.2 for cleaning instructions.

9.6Window Frame

9.6.1The window frame must be replaced when it becomes difficult to maintain a seal, or to keep the latch

closed. When replacing the window frame the acoustical foam inside the helmet should also be replaced.

9.7Chin Strap

9.7.1Replace the chin strap when worn.

9.8Filter Kit

9.8.1A filter kit is available for the alternate Air Control Valve. When the foam filter becomes soiled or deterio- rates, pry out the retaining ring with a small screwdriver. Remove the screen and dirty filter. Replace all three items with parts supplied in the kit.

10.0REPLACEMENT PARTS

10.1Supplied-Air Respirator Systems and Alternate Accessories

Respirators do not include alternate respirator hoses shown in Section 10.2. Respirator hose must be ordered separately.

Item Description

Stock No.

(-)

Apollo 60 HP Respirator,

 

 

w/constant-flow connector

21300

(-)

Apollo 60 HP Respirator,

 

 

w/air control valve

10505

(-)

Apollo 60 HP Respirator,

 

 

w/cool-air tube

10508

(-)

Apollo 60 HP Respirator,

 

 

w/climate control tube

10509

(-)

Air control valve with belt

04440

(-)

Cool-air tube with belt

04410

(-)

Climate control tube with belt

04411

(-)

Filter kit, air control valve

04381

(-)

Low pressure conversion kit.

 

 

Converts Apollo 60 HP (high pressure)

 

(Grade “D” Compressed Air)

 

 

respirator to LP (low pressure,

 

 

ambient air) respirator

22079

Image 13
Contents R N I N G Introduction Apollo 60 HP SUPPLIED-AIR RespiratorScope of manual Description Manual NoExposure to dangerous levels of lead or other Special Use Limitations Columbia ParkwayProtection Description Preparation Apollo 60 HP SUPPLIED-AIR Respirator InspectionAIR Supply Hose Minimum Pressure Setting, psi Length Air Volume and PressureCFC ACV CCT CAT OperationAir Control Valve, alternate, Figure AdjustmentsBasic Service Maintenance ProgramInspection Cleaning Inner Lens Service MaintenanceReplacing Perforated Outer Lenses, Figure SuspensionWindow Frame Replacement PartsChin Strap Filter KitSupplied-Air Respirator, Figure