HP Cell Phone storage works modular smart array 20 manual Fan Assembly, Power Supply Unit

Page 18

Removing and Replacing Components

2.Pull the drive out of the enclosure by about 3 cm (1 inch) so that it is disconnected from the backplane connector.

CAUTION: A drive with a rapidly spinning disk can be difficult to hold securely. To decrease the chance of dropping the drive, do not remove it completely from the enclosure until the disk has stopped rotating. This usually takes a few seconds.

3. When the disk is no longer spinning, remove the drive from the enclosure.

Installing a Drive Blank

Insert the drive blank into the enclosure, and push it in until it is firmly seated in the enclosure.

Installing a Replacement Drive

CAUTION: Take care when installing a drive. The drives in the enclosure are fragile.

1.Pull out the release lever on the drive as far as it can go.

2.Insert the replacement drive into the bay until it can go no further. About 1 cm (0.5 inch) of the drive protrudes from the bay.

3.Push the release lever all the way in. This action installs the drive completely in the bay and seats it firmly against the connector in the enclosure.

4.Observe the drive status LEDs to confirm that the replacement drive is functioning correctly.

Fan Assembly

1.Lift the release lever and pull the fan assembly out of the enclosure.

2.Slide the replacement fan assembly into the enclosure until it is firmly seated in the enclosure.

3.Confirm that the fan starts operating immediately and that the status LED is illuminated green.

Power Supply Unit

1.Disconnect the AC power cord from the defective power supply unit.

2.Squeeze the handle and the release lever together while pulling the defective power supply unit out of the enclosure.

3.Insert the replacement power supply unit into the empty bay until it is firmly seated in the enclosure.

4.Connect the AC power cord.

5.Confirm that the status LED on the replacement unit is illuminated green.

HP StorageWorks Modular Smart Array 20 Maintenance and Service Guide

3-3

Image 18
Contents July 2004 First Edition Part Number Page Contents Chapter Specifications About This Guide Audience AssumptionsTechnician Notes Where to Go for Additional Help Telephone NumbersIllustrated Parts Catalog Enclosure parts Description Spare part number Identifying Enclosure and Component Features Buttons and LEDs on Enclosure RearItem Description Disk Drives and Drive Blanks Drive in carrier and drive blankOnline LED Fault/ID LED Meaning Green Amber/blue Interpreting the Drive Status LEDsController Module Controller moduleFan Assembly Fan assemblyPower Supply Unit Power supply unitGrounding Methods Removing and Replacing ComponentsPreventing Electrostatic Damage Hot-pluggable Not hot-pluggableReplacement Procedures for Hot-Pluggable Components Disk Drive or Drive BlankFan Assembly Power Supply UnitBattery Packs and Cache in the Controller Module Controller ModuleRemoving and Replacing Components Replacement Procedures for Non-Hot-Pluggable Components Mounting Bracket CoversMidplane Board Removing and Replacing Components Backplane Board Ribbon CableVRM Power Supply UID Circuit BoardEnvironmental Specifications SpecificationsPower Specifications Nominal Value RangePhysical Specifications Form Dimensions Weight International cm

Cell Phone storage works modular smart array 20 specifications

The HP Cell Phone Storage Works Modular Smart Array 20 (MSA 20) represents an advanced storage solution designed to meet the growing data demands of mobile devices. As mobile computing continues to evolve, the need for scalable and efficient storage solutions becomes essential, and the MSA 20 addresses these requirements brilliantly.

One of the main features of the MSA 20 is its modular design, which allows for easy expansion and flexibility. The system supports up to 12 SFF (small form factor) hard drives, providing ample space for data storage while ensuring that future upgrades can be seamlessly integrated. This modularity not only makes the MSA 20 an ideal choice for businesses but also for individual users looking for personalized storage solutions.

In terms of technologies, the MSA 20 utilizes HP's innovative StorageWorks technology that enhances performance and reliability. The array is designed with a high-speed SAS (Serial Attached SCSI) interface, which allows for rapid data transfer rates. This is particularly beneficial for users who manage large files or require quick access to data, as the SAS interface minimizes latency and maximizes throughput.

Another significant characteristic of the MSA 20 is its robust data protection features. It incorporates advanced RAID (Redundant Array of Independent Disks) capabilities, which can be configured to meet various redundancy and performance needs. This feature ensures that data remains safe and accessible, even in the event of hardware failures.

The MSA 20 also supports various operating environments, including Windows and Linux, making it a versatile option for different users. Its compatibility with multiple OS platforms allows for a diverse array of applications, from business operations to personal use.

Moreover, the user-friendly management interface simplifies storage administration tasks. IT administrators or individual users can easily configure, monitor, and manage the array through a graphical interface or command-line tools. This ease of use ensures that even those with minimal technical expertise can effectively utilize the MSA 20.

In summary, the HP Cell Phone Storage Works Modular Smart Array 20 is an exceptional storage solution characterized by its modular design, advanced technologies, robust data protection, versatility across different operating systems, and user-friendly management interface. As mobile data continues to expand, the MSA 20 stands out as a reliable and efficient choice for those seeking to enhance their storage capabilities.