Roberts Gorden 30 - 125 Combat UHA-Series Technical Data, This product is not for residential use

Page 4

Combat® UHA-Series Technical Data

Model

 

30

45

60

75

100

125

150

175

200

225

250

300

350

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Input

[Btu/h] x [1000]

30

45

60

75

100

125

150

175

200

225

250

300

350

385

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Output

[Btu/h] x [1000]

24.6

36.9

49.2

61.5

82

102.5

123

143.5

164

184.5

205

246

288.6

315.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Efficiency

 

82% - All Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of Burners

 

2

3

4

5

6

7

7

8

9

10

11

12

14

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Connection

[in]

3/8

3/8

½

½

½

½

½

½

½

¾

¾

¾

¾

¾

Inlet Pressure

[in wc] NG Min.

5 - All Models

 

 

 

 

 

 

 

 

 

 

 

 

LPG Propane Min.

12 - All Models

 

 

 

 

 

 

 

 

 

 

 

NG & LP Propane Max.

14 - All Models

 

 

 

 

 

 

 

 

 

 

 

Electrical Supply

 

115 V / 60 Hz / 1 Ø - All Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full Load Amps @ 115 V

 

3.0

3.0

4.1

4.1

5.8

5.8

7.1

7.1

10.6

10.6

10.6

11.6

11.6

11.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Volume

[CFM]

691

691

1376

1376

1902

1902

2245

2245

3716

3716

3716

4663

4663

4663

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recommended Maximum

 

12

12

15

15

20

20

20

20

25

25

25

30

30

30

Mounting Height

[ft]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of Axial Fans

 

1

1

1

1

1

1

1

1

1

1

1

2

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Axial Fan Diameter

[in]

10

10

16

16

16

16

16

16

19.7

19.7

19.7

16

16

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horsepower

 

.06

.06

.08

.08

.2

.2

.2

.2

.3

.3

.3

.4

.4

.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor Amps @ 115 V

 

1.8

1.8

2.6

2.6

4.3

4.3

4.3

4.3

4.7

4.7

4.7

8.6

8.6

8.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor RPM

 

1630

1630

1030

1030

1175

1175

1200

1200

1085

1085

1100

1155

1155

1155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor Type

 

SP

SP

SP

SP

PSC

PSC

PSC

PSC

PSC

PSC

PSC

PSC

PSC

PSC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue Size

[in]

4 - All Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustion Air Size

[in]

4

4

4

4

4

4

4

4

4

4

4

5

5

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

[lb]

65

70

85

90

105

110

205

225

255

265

270

355

375

375

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Important Notice

The equipment described in this Data Sheet is suitable for most commercial and industrial heating applications. However, in certain environments, particularly where there is a chlorinated atmosphere (e.g. near degreasing plant or other solvent processes) or a particularly dusty atmosphere, specialist advice should be sought at the design stage. Roberts-Gordon reserves the right to alter product specification details without notice.

Installation Code and Annual Inspections:

All installations and service of ROBERTS GORDON® products must be performed by a contractor qualified in the installation and service of products sold and supplied by Roberts-Gordon and conform to all requirements set forth in the ROBERTS GORDON® manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate optimum performance and safety, Roberts-Gordon recommends that a qualified contractor annually inspect your ROBERTS GORDON® products and perform service where necessary, using only replacement parts sold and sup- plied by Roberts-Gordon, LLC.

Further Information: Applications, engineering and detailed guidance on systems design, installation and product performance is available through ROBERTS GORDON® representatives. Please contact us for any further information you may require, including the Installation, Operation and Service Manual.

This product is not for residential use.

This document is intended to assist licensed professionals in the exercise of their professional judgement.

Roberts-Gordon, LLC

European Office:

1250 William Street

Roberts Gordon Europe Limited

P.O. Box 44

Telephone: +44(0) 1902 494425

Buffalo, NY 14240-0044 USA

Fax: +44(0) 1902 403200

Telephone: 716.852.4400

 

Fax: 716.852.0854

 

Toll Free: 800.828.7450

 

www.rg-inc.com

 

© 2006 Roberts-Gordon, LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means

graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems – without written permission of Roberts-Gordon, LLC.

Printed in U.S.A.

UHASNA

5M 1106 Rev. A

Image 4
Contents 800.828.7450 Clearances to Combustibles Low Profile UHA Range Models 30 Range Models 30118 ModelClearances to Combustibles Standard UHA Range Models 150 Dimension Data Standard UHA Range Models 150Model 150 175 200 225 250 300 350 400 Combat UHA-Series Technical Data This product is not for residential use